Karin Apaza-Bedoya

Mrs. Karin Apaza-Bedoya

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2017 in Journal of Periodontal Research
Verified
Journal Article
Closed access
PDF file
KAKarin Apaza-Bedoya
Karin Apaza-Bedoya
MTM. Tarce
M. Tarce
CBC. A. M. Benfatti
C. A. M. Benfatti
Bruno HenriquesBruno Henriques
Bruno Henriques
MMM. T. Mathew
M. T. Mathew
Júlio C. M. SouzaJúlio C. M. Souza
Júlio C. M. Souza

22 September 2020 in Metals
Verified
Journal Article
Open access
PDF file
Júlio C. M. SouzaJúlio C. M. Souza
Júlio C. M. Souza
KAKarin Apaza-Bedoya
Karin Apaza-Bedoya
Cesar Augusto BenfattiCesar Augusto Benfatti
Cesar Augusto Benfatti
Filipe SilvaFilipe Silva
Filipe Silva
Bruno HenriquesBruno Henriques
Bruno Henriques
The main aim of this work was to perform a comprehensive review of findings reported by previous studies on the corrosion of titanium dental implants and consequent clinical detrimental effects to the patients. Most studies were performed by in vitro electrochemical tests and complemented with microscopic techniques to evaluate the corrosion behavior of the protective passive oxide film layer, namely TiO2. Results revealed that bacterial accumulation, dietary, inflammation, infection, and therapeutic solutions decrease the pH of the oral environment leading to the corrosion of titanium. Some therapeutic products used as mouthwash negatively affect the corrosion behavior of the titanium oxide film and promote changes on the implant surface. In addition, toothpaste and bleaching agents, can amplify the chemical reactivity of titanium since fluor ions interacting with the titanium oxide film. Furthermore, the number of in vivo studies is limited although corrosion signs have been found in retrieved implants. Histological evaluation revealed titanium macro- and micro-scale particles on the peri-implant tissues. As a consequence, progressive damage of the dental implants and the evolution of inflammatory reactions depend on the size, chemical composition, and concentration of submicron- and nanoparticles in the surrounding tissues and internalized by the cells. In fact, the damage of the implant surfaces results in the loss of material that compromises the implant surfaces, implant-abutment connections, and the interaction with soft tissues. The corrosion can be an initial trigger point for the development of biological or mechanical failures in dental implants.

3 July 2019 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
PDF file
EREdwin Ruales Ruales
Edwin Ruales Ruales
PPPatrícia Pauletto
Patrícia Pauletto
KAKarin Apaza-Bedoya
Karin Apaza-Bedoya
CVClaudia A. M. Volpato
Claudia A. M. Volpato
Mutlu ÖzcanMutlu Özcan
Mutlu Özcan
Cesar Augusto BenfattiCesar Augusto Benfatti
Cesar Augusto Benfatti

15 April 2019 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
MBMarco A. Bianchini
Marco A. Bianchini
MGMaria E. Galarraga‐Vinueza
Maria E. Galarraga‐Vinueza
KAKarin Apaza-Bedoya
Karin Apaza-Bedoya
JSJose M. De Souza
Jose M. De Souza
RMRicardo Magini
Ricardo Magini
FSFrank Schwarz
Frank Schwarz

17 October 2023 in Journal of Periodontology
Verified
Journal Article
Closed access
KAKarin Apaza-Bedoya
Karin Apaza-Bedoya
MGMaria Elisa Galarraga‐Vinueza
Maria Elisa Galarraga‐Vinueza
BCBruna Barbosa Correa
Bruna Barbosa Correa
FSFrank Schwarz
Frank Schwarz
MBMarco Aurélio Bianchini
Marco Aurélio Bianchini
CBCesar Augusto Magalhães Benfatti
Cesar Augusto Magalhães Benfatti

1 December 2018 in Journal of Oral Implantology
Verified
Journal Article
Closed access
CLCamilo Andres Villabona Lopez
Camilo Andres Villabona Lopez
MVMarco Antônio Amorin Vasco
Marco Antônio Amorin Vasco
EREdwin Ruales Ruales
Edwin Ruales Ruales
KAKarin Apaza-Bedoya
Karin Apaza-Bedoya
CBCesar Magalhaes Benfatti
Cesar Magalhaes Benfatti
TDTatiana Deliberador
Tatiana Deliberador
Zirconia has been presented as an alternative biomaterial to titanium, commercially presented as a single-body implant and/or as an abutment, demonstrating clinically biocompatible favorable results in white and rose esthetics. However, the number of long-term in vivo studies and mechanical tests evaluating the response of stress distribution compared with titanium implants is still limited. The aim of the study was to compare the principal peak stresses in the peri-implant bone around titanium and zirconia implants using the finite element method. Four groups of 3-dimensional models were constructed for the tests: G1, external hexagon titanium implant with a zirconia abutment; G2, zirconia implant with a zirconia abutment; G3, single-body titanium implant; and G4, single-body zirconia implant. Axial and oblique loads of 100 N at 45° were simulated in the prosthetic crown. The bone results showed that the peak stresses decreased by 12% in zirconia implants with 2 parts for axial load and 30% for the oblique load. In single-body implants, the peak stresses decreased 12% in the axial load and 34% in the oblique load when a zirconia implant was used compared with a titanium implant. Although the stress values in megapascals are similar, it can be concluded that the zirconia implants decrease the stress peaks at the peri-implant bone area around the implant platform when compared with titanium implants.