Rangachary Mukundan

Dr. Rangachary Mukundan

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2007 in Chemical Reviews
Verified
Journal Article
Closed access
RBRod Borup
Rod Borup
JMJeremy Meyers
Jeremy Meyers
BPBryan Pivovar
Bryan Pivovar
YKYu Seung Kim
Yu Seung Kim
RMRangachary Mukundan
Rangachary Mukundan
NINorio Iwashita∞
Norio Iwashita∞

3 September 2014 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
AWAdam Z. Weber
Adam Z. Weber
RBRodney L. Borup
Rodney L. Borup
RDRobert M. Darling
Robert M. Darling
Prodip K. DasProdip K. Das
Prodip K. Das
TDThomas J. Dursch
Thomas J. Dursch
IZIryna V. Zenyuk
Iryna V. Zenyuk
Polymer-electrolyte fuel cells are a promising energy-conversion technology. Over the last several decades significant progress has been made in increasing their performance and durability, of which continuum-level modeling of the transport processes has played an integral part. In this review, we examine the state-of-the-art modeling approaches, with a goal of elucidating the knowledge gaps and needs going forward in the field. In particular, the focus is on multiphase flow, especially in terms of understanding interactions at interfaces, and catalyst layers with a focus on the impacts of ionomer thin-films and multiscale phenomena. Overall, we highlight where there is consensus in terms of modeling approaches as well as opportunities for further improvement and clarification, including identification of several critical areas for future research.

15 March 2018 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
NMNatalia Macauley
Natalia Macauley
DPDennis D. Papadias
Dennis D. Papadias
JFJoseph Fairweather
Joseph Fairweather
DSDusan Spernjak
Dusan Spernjak
DLDavid Langlois
David Langlois
RBRodney L. Borup
Rodney L. Borup
Carbon corrosion is an important degradation mechanism that can impair PEMFC performance through the destruction of catalyst connectivity, collapse of the electrode pore structure, loss of hydrophobic character, and an increase of the catalyst particle size. In this study, carbon corrosion was quantified in situ by measurement of carbon dioxide in the fuel cell exhaust gases through non-dispersive infrared spectroscopy during simulated drive cycle operations consisting of potential cycling with varying upper and lower potential limits. These studies were conducted for three different types of carbon supports. A reduction in the catalyst layer thickness was observed during a simulated drive cycle operation with a concomitant decrease in catalyst layer porosity, which led to performance losses due to increased mass transport limitations. The observed thickness reduction was primarily due to compaction of the catalyst layer, with the actual mass of carbon oxidation (loss) contributing only a small fraction (< 20%). The dynamics of carbon corrosion are presented along with a model that simulates the transient and dynamic corrosion rates observed in our experiments. Accelerated carbon corrosion stress tests are presented and their effects are compared to those observed for the drive cycle test.

25 May 2023 in Nature Energy
Verified
Journal Article
Open access
PDF file
CLChungHyuk Lee
ChungHyuk Lee
WKWilton J. M. Kort-Kamp
Wilton J. M. Kort-Kamp
HYHaoran Yu
Haoran Yu
DCDavid A. Cullen
David A. Cullen
BPBrian M. Patterson
Brian M. Patterson
JSJacob S. Spendelow
Jacob S. Spendelow
Proton exchange membrane fuel cells (PEMFCs) are leading candidates to decarbonize the transport sector, but widespread deployment will require improvements in lifetime, fuel economy and cost. Here we present the grooved electrode, an alternative electrode structure that enhances PEMFC performance and durability by coupling high ionomer (ion-conducting binder) content for improved H+ transport with grooves for rapid O2 transport. Grooved electrodes provide up to 50% higher performance than state-of-the-art conventional electrodes under standard operating conditions. Fuel cell diagnostics combined with multiphysics modelling demonstrate that grooved electrodes provide facile O2 transport despite their high ionomer content, enabling improved reaction rate uniformity. Grooved electrodes also provide improved durability, with less performance loss after carbon corrosion compared with baseline electrodes. Machine learning analysis demonstrates the potential to further optimize grooved structures for next-generation PEMFCs with enhanced performance and durability, enabling smaller and cheaper fuel cell stacks with higher fuel efficiency.

14 February 2014 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
WGWei Gao
Wei Gao
GWGang Wu
Gang Wu
MJMichael Janicke
Michael Janicke
DCDavid A. Cullen
David A. Cullen
RMRangachary Mukundan
Rangachary Mukundan
PZPiotr Zelenay
Piotr Zelenay

15 May 2018 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
SSSarah Stariha
Sarah Stariha
NMNatalia Macauley
Natalia Macauley
BSBrian T. Sneed
Brian T. Sneed
DLDavid Langlois
David Langlois
KMKarren L. More
Karren L. More
RBRodney L. Borup
Rodney L. Borup
The U.S. Department of Energy (DOE) set the 2020 durability target for polymer electrolyte membrane fuel cell transportation applications at 5000 hours. Since it is impractical to test every fuel cell for this length of time, there is ever increasing interest in developing accelerated stress tests (ASTs) that can accurately simulate the material component degradation in the membrane electrode assembly (MEA) observed under automotive operating conditions, but over a much shorter time frame. In this work, a square-wave catalyst AST was examined that shows a 5X time acceleration factor over the triangle-wave catalyst AST and a 25X time acceleration factor over the modified wet drive-cycle catalyst durability protocol, significantly decreasing the testing time. These acceleration factors were correlated to the platinum (Pt) particle size increase and associated decrease in electrochemical surface area (ECSA). This square-wave AST has been adopted by the DOE as a standard protocol to evaluate catalyst durability. We also compare three catalyst-durability protocols using state-of-the-art platinum-cobalt catalysts supported on high surface area carbon (SOA Pt-Co/HSAC) in the cathode catalyst layer. The results for each of the three tests showed both catalyst particle size increase and transition metal leaching. Moreover the acceleration factors for the alloy catalysts were smaller due to Co leaching being the predominant mechanism of voltage decay in ∼5 nm PtCo/C catalysts. Finally, an extremely harsh carbon corrosion AST was run using the same SOA Pt-Co/HSAC catalyst. This showed minimal change in particle size and a low percentage Co loss from the cathode catalyst particles, despite a significant loss in catalyst layer thickness and cell performance. The carbon corrosion rates during these various ASTs were directly measured by monitoring the CO2 emission from the cathode, further confirming the ability of the square-wave AST to evaluate the electro-catalyst independently of the support.