This paper presents a simple method for the rapid synthesis of magnetite/hydroxyapatite composite particles. In this method, superparamagnetic magnetite nanoparticles are first synthesized by coprecipitation using ferrous chloride and ferric chloride. Immediately following the synthesis, carbonate-substituted (B-type) hydroxyapatite particles are mechanochemically synthesized by wet milling dicalcium phosphate dihydrate and calcium carbonate in a dispersed suspension of magnetite nanoparticles, during which the magnetite nanoparticles are incorporated into the hydroxyapatite matrix. We observed that the resultant magnetite/hydroxyapatite composites possessed a homogeneous dispersion of magnetite nanoparticles, characterized by an absence of large aggregates. When this material was subjected to an alternating magnetic field, the heat generated increased with increasing magnetite concentration. For a magnetite concentration of 30 mass%, a temperature increase greater than 20 K was achieved in less than 50 s. These results suggest that our composites exhibit good hyperthermia properties and are promising candidates for hyperthermia treatments.
Deconvolution analysis (DA) based on singular value decomposition (SVD) has been widely accepted for quantification of cerebral blood flow (CBF) using dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI). When using this method, the elements in the diagonal matrix obtained by SVD are set to zero when they are smaller than the threshold value given beforehand. In the present study, we investigated the effect of the threshold value on the accuracy of the CBF values obtained by this method using computer simulations. We also investigated the threshold value giving the CBF closest to the assumed value (optimal threshold value) under various conditions. The CBF values obtained by this method largely depended on the threshold value. Both the mean and the standard deviation of the estimated CBF values decreased with increasing threshold value. The optimal threshold value decreased with increasing signal-to-noise ratio and CBF, and increased with increasing cerebral blood volume. Although delay and dispersion in the arterial input function also affected the relationship between the estimated CBF and threshold values, the optimal threshold value tended to be nearly constant. In conclusion, our results suggest that the threshold value should be carefully considered when quantifying CBF in terms of absolute values using DSC-MRI for DA based on SVD. We believe that this study will be helpful in selecting the threshold value in SVD.
11 June 2011 in Radiological Physics and Technology