Nobuyoshi Tanki

Nobuyoshi Tanki

Auto-generated profile, based on publicly available information

Nobuyoshi Tanki

Butsuryo College of Osaka

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2011 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
KMKenya Murase
Kenya Murase
NTNobuyoshi Tanki
Nobuyoshi Tanki

25 November 2009 in Japanese Journal of Radiological Technology
Verified
Journal Article
Open access
PDF file
HMHiroyuki Muranaka
Hiroyuki Muranaka
THTakayoshi Horiguchi
Takayoshi Horiguchi
YUYoshitake Ueda
Yoshitake Ueda
SUShuji Usui
Shuji Usui
NTNobuyoshi Tanki
Nobuyoshi Tanki
ONOsamu Nakamura
Osamu Nakamura
Purpose: We evaluate radiofrequency (RF) heating of two kinds of hip joint implants of different sizes, shapes and materials. Temperature rises at various positions of each implant are measured and compared with a computer simulation based on electromagnetic-field analysis. Methods: Two kinds of implants made of cobalt-chromium alloy and titanium alloy were embedded at a 2-cm depth of tissue-equivalent gel-phantom. The phantom was placed parallel to the static magnetic field of a 1.5 T MRI device. Scans were conducted at the specific absorption rate of 2.5 W/kg for 15 min, and temperatures were recorded with RF-transparent fiberoptic sensors. Temperatures of the implant surface were measured at 6 positions, from the tip to the head. Measured temperature rises were compared with the results of electromagnetic-field analysis. Results: The maximum temperature rise was observed at the tip of each implant, and it was 9.0°C for the cobalt- chromium implant and 5.3°C for the titanium implant. The simulated heating positions with electromagnetic-field analysis accorded with experimental results. However, a difference in temperature rise was seen with the titanium implant. Conclusion: RF heating was confirmed to take place at both ends of the implants in spite of their different shapes. The maximum temperature rise was observed at the tip where there is large curvature. The value was found to depend on physical properties of the implant materials. The discrepancy between experimental and simulated temperature rises was presumed to be the result of an incomplete model for the titanium implant.

1 January 2011 in Magnetic Resonance in Medical Sciences
Verified
Journal Article
Open access
PDF file
HMHiroyuki Muranaka
Hiroyuki Muranaka
THTakayoshi Horiguchi
Takayoshi Horiguchi
YUYoshitake Ueda
Yoshitake Ueda
NTNobuyoshi Tanki
Nobuyoshi Tanki
We evaluated radiofrequency (RF) heating of various implants embedded in a gel phantom during magnetic resonance (MR) procedures. We examined the dependence of RF heating on variation in specific absorption rate (SAR) and angle between the implant and the static magnetic field (B0) and on the displacement of the phantom in the irradiation coil using a 1.5-tesla MR system, and we compared the influence of RF heating on the same implant using a 3.0T MR system. Our results support the occurrence of RF heating of implants made of non-magnetizing metal. We observed greater RF heating when the implant was set parallel to B0, embedded at a shallower depth, and placed at the center of the RF irradiation coil. We also confirmed that the rise in temperature was proportionate to the increase in SAR. We considered the difference in temperature elevation on depth of embedding to reflect the skin-depth effect of RF intensity for both the 1.5- and 3.0-T MR systems.

1 February 2016 in European Journal of Pharmaceutics and Biopharmaceutics
Verified
Journal Article
Closed access
TSTomotaka Shingaki
Tomotaka Shingaki
YKYumiko Katayama
Yumiko Katayama
TNTakayoshi Nakaoka
Takayoshi Nakaoka
SISatsuki Irie
Satsuki Irie
KOKayo Onoe
Kayo Onoe
YWYasuyoshi Watanabe
Yasuyoshi Watanabe

5 December 2014 in Radiological Physics and Technology
Verified
Journal Article
Closed access
PDF file
SSShigeyoshi Saito
Shigeyoshi Saito
YMYuki Mori
Yuki Mori
NTNobuyoshi Tanki
Nobuyoshi Tanki
YYYoshichika Yoshioka
Yoshichika Yoshioka
KMKenya Murase
Kenya Murase

8 November 2015 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
TKToshizo Katsuda
Toshizo Katsuda
RGRumi Gotanda
Rumi Gotanda
TGTatsuhiro Gotanda
Tatsuhiro Gotanda
TATakuya Akagawa
Takuya Akagawa
NTNobuyoshi Tanki
Nobuyoshi Tanki
KYKouichi Yabunaka
Kouichi Yabunaka
Gafchromic films are used for X‐ray dose measurements during diagnostic examinations and have begun to be used for three‐dimensional X‐ray dose measurements using the high‐resolution characteristics of Gafchromic films for computed tomography. However, the problem of unevenness in Gafchromic film active layers needs to be resolved. Double exposures using X‐rays are performed during therapeutic radiology, although this is difficult for a diagnostic examination because of a heel effect. Thus, it has been suggested that ultraviolet (UV) radiation be used as a substitute for X‐rays. However, the appropriate UV wavelength has not been determined. Thus, we conducted this study to decide an appropriate UV wavelength. UV peak wavelengths of 245 nm (UV‐A), 310 nm (UV‐B), and 365 nm (UV‐C) were used to irradiate EBT2 and EBT3 films. Each UV wavelength was irradiated for 5, 15, 30, and 60 min, and irradiation was then repeated every 60 min up to 360 min. Gafchromic films were scanned after every irradiation using a flatbed scanner. Images were split into RGB images, and red images were analyzed using ImageJ, version 1.44, image analysis software. A region of interest (ROI) one‐half inch in diameter was placed in the center of subtracted Gafchromic film images, and UV irradiation times were plotted against mean pixel values. There were reactions in the front and back of Gafchromic EBT3 and the back of Gafchromic EBT2 with UV‐A and UV‐B. However, UV‐C resulted in some reactions in both sides of Gafchromic EBT2 and EBT3. The UV‐A and UV‐B wavelengths should be used.PACS number(s): 87.53 Bn