John Emerson Leguizamón

Dr. John Emerson Leguizamón


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2020 in Frontiers in Microbiology
Verified
Journal Article
Open access
PDF file
CVCarolina Villamil
Carolina Villamil
MCMartha Nancy Calderon
Martha Nancy Calderon
MAMaria Mercedes Arias
Maria Mercedes Arias
JLJohn Emerson Leguizamón
John Emerson Leguizamón
Salmonellosis is a foodborne disease caused by Salmonella spp. Although cell culture is the gold standard for its identification, validated molecular methods are becoming an alternative, because of their rapidity, selectivity, and specificity. A simplex and duplex droplet digital polymerase chain reaction (ddPCR)-based method for the identification and quantification of Salmonella using ttr, invA, hilA, spaQ, and siiA gene sequences was validated. The method has high specificity, working interval between 8 and 8,000 cp/μL in ddPCR reaction, a limit of detection of 0.5 copies/μL, and precision ranging between 5 and 10% measured as a repeatability standard deviation. The relative standard measurement uncertainty was between 2 and 12%. This tool will improve food safety in national consumption products and will increase the competitiveness in agricultural product trade.

25 August 2021 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
NLNicolás Mateo González López
Nicolás Mateo González López
KHKevin Andrey Huertas-Ortiz
Kevin Andrey Huertas-Ortiz
JLJohn Emerson Leguizamón
John Emerson Leguizamón
MAMaría Mercedes Arias-Cortés
María Mercedes Arias-Cortés
CPClaudia Patricia Tere Peña
Claudia Patricia Tere Peña
ZMZuly Jenny Rivera Monroy
Zuly Jenny Rivera Monroy
Mycotoxins are secondary metabolites that are known to be toxic to humans and animals. Omics tools are important to establish prevention, control and mitigation strategies of mycotoxins in food.

1 February 2021 in Molecular and Cellular Probes
Verified
Journal Article
Closed access
CVCarolina Villamil Vallejo
Carolina Villamil Vallejo
CPClaudia Patricia Tere Peña
Claudia Patricia Tere Peña
MOMartha Nancy Calderón Ozuna
Martha Nancy Calderón Ozuna
MAMaría Mercedes Arias
María Mercedes Arias
JLJohn Emerson Leguizamón
John Emerson Leguizamón

15 November 2024 in Methods and Protocols
Verified
Journal Article
Open access
PDF file
CPClaudia Patricia Tere Peña
Claudia Patricia Tere Peña
MOMartha Nancy Calderón Ozuna
Martha Nancy Calderón Ozuna
JLJohn Emerson Leguizamón
John Emerson Leguizamón
Escherichia coli O157:H7, a Shiga-toxin-producing E. coli (STEC), is an important pathogen related to foodborne disease that is responsible for a growing number of outbreaks worldwide and has been detected in processed meats, dairy, and fresh vegetables. Although culturing is the gold standard method for detection of this bacterium, molecular methods based on nucleic acid amplification techniques such as PCR are becoming more common because of their rapidity, sensitivity, and specificity. However, to ensure reliable results among the several alternative PCR protocols (e.g., commercial kits and reference methods), different measurement assurance tools, including validated methods, reference materials, and proficiency tests, among others, are required. Herein, we present a digital PCR method validation for E. coli O157:H7 detection and quantification using seven specific gene sequences; this method quantified nucleic acids from different E. coli serotypes, with a detection range of 6.6 to 7900 copies/µL and a repeatability standard deviation over the concentration range of 1% to 13.6%. The relative standard uncertainty was 3.5–14.6%, and the detection limit was 0.27 copies/µL. Subsequently, two batches of a candidate reference material based on E. coli O157:H7 genomic DNA were then produced and characterized for evaluation of copy number concentration with the validated ddPCR method, with assigned values of 164,770 ± 9251 and 172 ± 9 copies/μL. Thus, this study demonstrated the development of a validated method and reference material for dPCR and qPCR detection of E. coli O157:H7, a key STEC responsible for food poisoning.

13 April 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
ADAlison S. Devonshire
Alison S. Devonshire
EBEloise Busby
Eloise Busby
GJGerwyn M. Jones
Gerwyn M. Jones
DODenise M. O’sullivan
Denise M. O’sullivan
AFAna Fernandez-Gonzalez
Ana Fernandez-Gonzalez
JHJim Huggett
Jim Huggett
Infection with human immunodeficiency virus (HIV)-1 leads to acquired immunodeficiency syndrome (AIDS) if left untreated. According to UN figures, approximately 39 million people globally were living with HIV in 2022, with 76% of those individuals accessing antiretroviral therapy. Measurement of plasma viral RNA load using calibrated nucleic acid amplification tests (like reverse transcription quantitative PCR, RT-qPCR) is routinely performed to monitor response to treatment and ultimately prevent viral transmission. RNA quantities measured by commercial tests can vary over many orders of magnitude, from trace single copy levels to, in cases, over 10 9 /mL of plasma, presenting an analytical challenge for calibrating across a broad measurement range. Interlaboratory study CCQM-P199 “HIV-1 RNA copy number quantification” (April to September 2019) was conducted under the auspices of the Consultative Committee for Amount of Substance (CCQM) Nucleic Acid analysis Working Group (NAWG), with the aims of supporting national metrology institutes (NMIs) and designated institutes (DIs) development of the capacity and evaluating candidate reference measurement procedures for applied viral nucleic acid measurements. Thirteen laboratories participated in CCQM-P199 and were requested to report the RNA copy number concentration, expressed in copies per microliter, of the HIV-1 group specific antigen ( gag ) gene of in vitro transcribed RNA molecules at low (≈ 10 3 /μL) and high concentration (≈ 10 9 /μL) (Study Materials 1 and 2, linked by gravimetric dilution) and purified genomic RNA from cultured virus (Study Material 3). Study Materials 1 and 3 were measured by participants using one-step reverse transcription digital PCR (RT-dPCR) (Bio-Rad reagents) and/or two-step RT-dPCR with alternative cDNA synthesis reagents. Study Material 2 was measured by both RT-dPCR (one-step) ( n = 4) and orthogonal methods: single molecule flow cytometric counting ( n = 2), high performance liquid chromatograph (HPLC) ( n = 1) and isotype dilution-mass spectrometry (ID-MS) ( n = 1). Interlaboratory reproducibilities (expressed as %CV) were 21.4 %, 15.3 % and 22.0 % for Study Materials 1, 2 and 3 respectively. Analysis of overdispersion showed that the interlaboratory variation for all three Study Materials was not accounted for in their reported uncertainties, indicating uncharacterized sources of variation remain. Although the mean values of RT-dPCR and orthogonal method results were not statistically significantly different ( p = 0.46), the extrapolated mean Study Material 2 results were higher than mean Study Material 1 results (1196 vs . 808 /μL; p < 0.05). Follow-up analysis of Study Material 2 purity by ultra-performance liquid chromatography (UPLC) indicated higher molecular weight (MW) impurities constituted 16.6 % of the molecules, which are hypothesised to be the cause of the HPLC and ID-MS results being higher than the majority of Study Material 1 and 2 results. This study demonstrates that reproducible measurement of RNA templates was achieved by metrology laboratories, illustrating the potential of RT-dPCR combined with complimentary orthogonal approaches to support traceability and precision of contemporary methods for RNA quantification. This study also highlighted that detailed characterization of RNA materials and sources of bias affecting measurements such as RT efficiency is needed to further establish RT-dPCR as a primary reference measurement procedure for RNA copy number quantification.

6 September 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
DBDaniel Burke
Daniel Burke
ADAlison S. Devonshire
Alison S. Devonshire
LPLeonardo B. Pinheiro
Leonardo B. Pinheiro
GJGerwyn M. Jones
Gerwyn M. Jones
KGKate R. Griffiths
Kate R. Griffiths
JHJim Huggett
Jim Huggett
For the impact of genomic testing from liquid biopsies to be maximized, mechanisms to ensure reproducible and comparable test performance will be required. This can be established and maintained through reference measurement procedures and materials with property values that are internationally comparable through traceability to a common standard. To achieve this objective, an interlaboratory study was organised to explore digital PCR (dPCR) for standardisation of cell-free DNA (cfDNA) quantification. Blinded samples of wild-type/variant mixtures of two DNA sequences ( BRAF p.V600E single nucleotide variant or EGFR exon 19 deletion) were provided to 12 laboratories. Laboratories independently designed and applied dPCR assays to determine absolute and relative quantities, with no guidance provided to harmonise the approach. The mean and coefficient of variation (CV) of copy number concentrations for variant sequences were 18 copies/μL (CV 7.2%) ( BRAF variant sample) and 9 copies/μL (CV 25%) ( EGFR variant sample) while the mean variant allele frequencies (vAF) were 8.0% (CV 5.3%) and 0.080% (CV 29%) respectively. This study demonstrated that dPCR was capable of exceptional technical accuracy for variant copy number concentration and vAF, even when different assays and platforms were used. This implies that dPCR offers a unique analytical methodology that can be deployed globally in supporting comparability for cfDNA testing based on the existing framework of the International System of units of measurement.