Ninoska Isabel Bojorge Ramírez

Prof. Dr. Ninoska Isabel Bojorge Ramírez

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2019 in Engineering in Life Sciences
Verified
Journal Article
Closed access
PDF file
RRRuan S. A. Ribeiro
Ruan S. A. Ribeiro
BPBruno C. Pohlmann
Bruno C. Pohlmann
VCVeronica Calado
Veronica Calado
Ninoska Isabel Bojorge RamírezNinoska Isabel Bojorge Ramírez
Ninoska Isabel Bojorge Ramírez
NPNei Pereira
Nei Pereira

26 December 2022 in Biofuels, Bioproducts and Biorefining
Verified
Journal Article
Closed access
RBRicardo Gonzalo Ramírez B
Ricardo Gonzalo Ramírez B
EAEliana Mossé Mosse Alhadeff
Eliana Mossé Mosse Alhadeff
Ninoska Isabel Bojorge RamírezNinoska Isabel Bojorge Ramírez
Ninoska Isabel Bojorge Ramírez
LTLuiz E. M. Trales
Luiz E. M. Trales
GPGabrielle A. D. Pazos
Gabrielle A. D. Pazos

18 January 2023 in Molecules
Verified
Journal Article
Open access
PDF file
RBRicardo Gonzalo Ramírez B
Ricardo Gonzalo Ramírez B
LCLivia Silva Chaves
Livia Silva Chaves
Ninoska Isabel Bojorge RamírezNinoska Isabel Bojorge Ramírez
Ninoska Isabel Bojorge Ramírez
NJNei Pereira Jr.
Nei Pereira Jr.
A study to produce cellulose nanofibrils (CNF) from kraft cellulose pulp was conducted using a centroid simplex mixture design. The enzyme blend contains 69% endoglucanase and 31% exoglucanase. The central composite rotational design (CCRD) optimized the CNF production process by achieving a higher crystallinity index. It thus corresponded to a solid loading of 15 g/L and an enzyme loading of 0.974. Using the Segal formula, the crystallinity index (CrI) of the CNF was determined by X-ray diffraction to be 80.87%. The average diameter of the CNF prepared by enzymatic hydrolysis was 550–600 nm, while the one produced by enzymatic hydrolysis and with ultrasonic dispersion was 250–300 nm. Finally, synergistic interactions between the enzymes involved in nanocellulose production were demonstrated, with Colby factor values greater than one.

13 January 2020 in Biotechnology and Applied Biochemistry
Verified
Journal Article
Closed access
PDF file
RRRuan Stevan Almeida Ribeiro
Ruan Stevan Almeida Ribeiro
Ninoska Isabel Bojorge RamírezNinoska Isabel Bojorge Ramírez
Ninoska Isabel Bojorge Ramírez
NJNei Pereira Jr.
Nei Pereira Jr.

7 January 2025 in Biofuels, Bioproducts and Biorefining
Verified
Journal Article
Closed access
IMIsabela Rosa Marchette
Isabela Rosa Marchette
RCRenata Beatriz Calegari Cavallari
Renata Beatriz Calegari Cavallari
FRFernanda Do Canto Rothier
Fernanda Do Canto Rothier
Ninoska Isabel Bojorge RamírezNinoska Isabel Bojorge Ramírez
Ninoska Isabel Bojorge Ramírez
EAEliana Mossé Mosse Alhadeff
Eliana Mossé Mosse Alhadeff
BSBrunno Ferreira Santos
Brunno Ferreira Santos

1 July 2017 in Brazilian Journal of Chemical Engineering
Verified
Journal Article
Open access
PDF file
VSV. M. Santos
V. M. Santos
RRR. S. A. Ribeiro
R. S. A. Ribeiro
ABA. J. T. Bosco
A. J. T. Bosco
EAE. M. Alhadeff
E. M. Alhadeff
Ninoska Isabel Bojorge RamírezNinoska Isabel Bojorge Ramírez
Ninoska Isabel Bojorge Ramírez
Biosensors based on nanomaterial composites have been investigated for their potential to function as high sensitivity signal response devices. In the present study, we report the fabrication of silver nanoparticles (AgNPs) on a graphite epoxy composite electrode (GEC) and mixed with the polyaniline (a conductive emeraldine salt form polymer) composite electrode (AgNPs/PANI/GEC), in order to compare the performance of the generated electrochemical response signals. Cyclic voltammetry tests were conducted to compare the quality and intensity of signals from the different prepared electrodes. Tests for the AgNPs/PANI/GEC electrodes were made with and without the enzymes alcohol oxidase and horseradish peroxidase immobilized on the composite surface. The prepared AgNPs/PANI/GEC nanocomposite was evaluated by thermal analysis. Scanning electron microscopy images and EDX were obtained for characterization of the electrode surface morphology. Square wave voltammetry techniques were then employed for ethanol analysis with the AOX/HRP/AgNPs/PANI/GEC biosensor achieving good results in a range of 0.37M to 0.65 M.