Purpose: A hysteroscopic metroplasty was performed for women with recurrent pregnancy loss owing to a uterine septum, following which some women became infertile. The aim of this study was to elucidate the risk factors of secondary infertility 1 year after hysteroscopic metroplasty for a uterine septum.Methods: A retrospective, single‐center, cohort study included women with a history of at least two miscarriages that had been attributed to a uterine septum who underwent a hysteroscopic metroplasty. The patients’ background data were compared between the patients who conceived and those who remained infertile at 1 year postoperatively. The data were analyzed by using the Mann–Whitney U‐test and multivariate analyses.Results: The postoperative live birth rate was 83.9% (n = 26), with persistent infertility in five women at 1 year. When comparing the pregnancy group with the infertile group, the women in the postoperative infertility group were significantly older than those in the postoperative pregnancy group. The multivariate analysis showed that age was an independent risk factor for persistent infertility.Conclusion: Age was identified as an independent risk factor for postoperative secondary infertility. Therefore, surgery as early as possible is recommended.
Osteopontin (OPN) is a multifunctional secreted glycoprotein. We evaluated OPN concentrations in blood and follicular fluid (FF) during the ovarian cycle and their relationship with the production of vascular endothelial growth factor (VEGF), which is involved in the pathophysiology of ovarian hyperstimulation syndrome (OHSS). Twenty-two women undergoing in vitro fertilization (minimal stimulation protocol with clomiphene citrate) were enrolled. Samples were collected (a) on the third day of withdrawal bleeding, (b) 2 days before oocyte retrieval, and (c) on the day of oocyte retrieval. FF was collected during oocyte retrieval. The OPN concentration in each specimen and the VEGF concentration in FF was measured by enzyme-linked immunosorbent assays. Plasma OPN concentrations were (in ng/mL): (a) 416 ± 37.2, (b) 378 ± 35.8, and (c) 390 ± 40.0, with no significant differences between the groups. The OPN concentration in FF was 106 ± 13.4 ng/mL. A positive correlation was found between OPN concentrations in FF and plasma samples. A positive correlation was also found between plasma OPN and FF VEGF concentrations, irrespective of the blood-sampling period. Plasma OPN concentration is suggested to reflect the FF VEGF level at oocyte retrieval and maybe a novel clinical marker for predicting the risk for OHSS.
Background/Objectives: Determining when to stop septal incision is a practical issue in hysteroscopic metroplasty (HM). We describe a combined intraoperative approach targeting an approximately 5 mm residual septum. Methods: This single-center retrospective case series included 32 consecutive patients undergoing HM by one surgeon between May 2024 and April 2026. Electrode-based semi-quantitative assessment was combined with sonohysterographic fundal thickness monitoring. Postoperative morphology was assessed at 2 months. Stored final intraoperative ultrasound images were retrospectively evaluated when available. Results: All 32 patients completed postoperative imaging and second-look hysteroscopy. Median postoperative residual septum length was 7.0 mm (interquartile range, 5.7–8.6; range, 2.9–10.0); 30 patients (93.8%) had a residual length below 10 mm and two had a length of 10.0 mm. Final intraoperative images were available in 16 patients: median full fundal thickness was 13.9 mm (range, 11.2–15.8), and the calculated residual length was 3.6 mm (range, 0.6–5.5). No adhesions occurred at the uterine-body incision site; one cervical adhesion required subsequent excision. No uterine perforation or major intraoperative hemorrhage occurred. No postoperative infection or repeat surgery for a residual septum was recorded through second-look hysteroscopy (median, 62 days; range, 59–93 days). Conclusions: This series describes the application and feasibility of two complementary intraoperative assessments. Measurement accuracy, reproducibility, and comparative safety or effectiveness remain untested and require prospective evaluation.