The European energy transition is leading to a transformed electricity system, where Distributed Energy Resources (DERs) will play a substantial role. Renewable Energy Sources (RES) will challenge the key operational obligation of real-time balancing and the need for flexibility will consequently increase. The introduction of a local flexibility market (LFM) would allow the trading of flexibility supplied by both producing and consuming units at the distribution level, providing market access to DERs, a support tool for Distribution System Operators (DSOs) and a value stream for energy suppliers. Aggregators and DSOs for different reasons can enhance the valuation of flexible DERs. Several research papers have assumed aggregators fully interacting with the electricity markets and DSOs contracting services with power system actors. These interactions are still not allowed in many European countries. This article aims to analyze the European regulation to identify the most important enablers and pave the way towards the full exploitation of DER flexibility, culminating in the establishment of an LFM. Therefore, three main stages, emerging from the progressive withdrawal of the current regulatory and market barriers, are identified: (1) enabling the aggregator’s trading, (2) evolution of the DSO’s role, and (3) key-design challenges of an LFM.
In this paper, we present a large-bandwidth, high-current, and high-voltage measuring system for pulse measurements in pulsed power systems. The developed sensors can be easily calibrated, require no extensive (3-D) modeling, are very compact, are inexpensive, and have a bandwidth of up to several gigahertz. Moreover, they can be used in any pulsed power system, where a pulse source is connected to its load by a coaxial cable (without disturbing the coaxial geometry). We developed this sensor system for the use with our nanosecond pulse source system. The type of sensors we used is D-dot and B-dot sensors, which are compactly mounted on the coaxial cable that connects our nanosecond pulse source to its load. This enables us to measure the characteristics of each sensor very precisely with a vector network analyzer. With these characteristics-combined with the characteristics of the measuring cable assembly-we can numerically reconstruct the voltage and current waveforms that passed the sensor positions. Our calibration approach, the mounting on the coaxial cable and the postprocessing of the results makes these sensors very flexible. While we use the sensors for energy measurements, camera triggering, and the general measurement of the pulses, other researchers can use these types of sensors as well in any system, where a (coaxial) cable connects a pulse source to its load.
Water can be activated by applying plasma to water, for instance, by creating plasma inside (bubbles in) the water, or along a water surface. Plasma-activated water (PAW) typically contains hydrogen peroxide, nitrates, nitrites, and peroxynitrite, and typically has a pH ranging from 2 to 4. The components of PAW and the low pH have proven synergistic antimicrobial effects against bacteria, biofilms, yeasts, and other microorganisms. This paper describes a power modulator and a plasma reactor system for high-yield production of PAW at high production rate. A compact and solid-state dual resonant system has been realized and successfully demonstrated for industrial PAW production. The system generates up to 80-kV (theoretical 120 kV is possible) dual-resonant high-voltage pulses with an oscillation frequency up to 2 MHz, pulse repetition rate > 20 kHz, and an average power of 800-W continuous. In addition to the power modulator, the PAW production system consists of a transient arc plasma reactor and a loop system. Depending on the application, the system is able to activate 10-100 L/h. The disinfecting properties of the PAW production system have been verified by experiments on the reduction of Staphylococcus Epidermidis. Directly after its production, the log reduction of S. Epidermidis can be as high as >8 log. During a period of at least 40 min after its production, the PAW has “mild” disinfecting properties, being able to deactivate S. Epidermidis by 3-4.1 log.
The development of active distribution grids requires more accurate and lower computational cost state estimation. In this paper, the authors investigate a decentralized learning-based distribution system state estimation (DSSE) approach for large distribution grids. The proposed approach decomposes the feeder-level DSSE into subarea-level estimation problems that can be solved independently. The proposed method is decentralized pruned physics-aware neural network (D-P2N2). The physical grid topology is used to parsimoniously design the connections between different hidden layers of the D-P2N2. Monte Carlo simulations based on one-year of load consumption data collected from smart meters for a three-phase distribution system power flow are developed to generate the measurement and voltage state data. The IEEE 123-node system is selected as the test network to benchmark the proposed algorithm against the classic weighted least squares and state-of-the-art learning-based DSSE approaches. Numerical results show that the D-P2N2 outperforms the state-of-the-art methods in terms of estimation accuracy and computational efficiency.
17 November 2017 in IEEE Transactions on Plasma Science
A compact magnetic pulse compression (MPC) topology with only two magnetic cores and a continuous repetition rate of 20 kHz is presented. The demand for higher average output powers of pulsed power systems can be achieved by an increase of the pulse rate frequency (PRF). The PRF is often limited by the switching speed or recovery of the main switch and also the complex behavior of the magnetic materials. With the advent of insulated gate bipolar transistors and the nanocrystalline soft magnetic material, PRFs of tens of kilohertz are feasible if a suitable MPC topology is applied. The presented MPC is based on an existing topology that has been significantly improved to enable high-frequency pulse generation. A design method using 3-D magnetostatic and transient magnetic simulations is introduced to enable optimization of the magnetic switching components. A 20 kHz, 60 kV, and 52 ns full width at half maximum (FWHM) MPC generator is designed, built, and tested for a $100~\Omega $ load. Simulations suggest that a PRF up to 50 kHz is achievable, but continuous operation will likely be limited by thermal management.