Minh-Quan Tran

Mr. Minh-Quan Tran

Eindhoven University of Technology
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2023 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
TTTrung Thai Tran
Trung Thai Tran
SGSriram Karthik Gurumurthy
Sriram Karthik Gurumurthy
Minh-Quan TranMinh-Quan Tran
Minh-Quan Tran
TNThien-An Nguyen-Huu
Thien-An Nguyen-Huu
THTobias Heins
Tobias Heins
PNPhuong H. Nguyen
Phuong H. Nguyen
The Andronov-Hopf based Virtual Oscillator Control (AHO) is an emerging control strategy for grid-forming converters (GFC) to ensure the stability of the future power system with high level of penetration of renewable energies. AHO allows converters to operate in either grid-connected and islanded operating modes. However, the application of this control strategy is limited due to the inherent problem in simultaneous controlling active and reactive power output of GFCs. This paper presents a modification in AHO control structure, and adopts a wide-band grid impedance estimation to improve the dispatchability of AHO in grid-connected mode. The impedance estimation algorithm is embedded into the control loop of AHO, and requires only the measurement of the voltages and currents at the point of common coupling. Thus it is cost-effective and practical. The performance of the proposed method is validated in both simplestructure, and large low-voltage benchmark distribution systems, using MATLAB/Simulink software and the real-time Opal-RT platform. The simulation results confirm the high-accuracy of the estimation and the capability of AHO in simultaneously controlling active and reactive power with zero steady-state errors. Additionally, this paper discusses the small-signal stability and Lyapunov large signal stability of the proposed AHO and compares it to existing methods.

24 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
Minh-Quan TranMinh-Quan Tran
Minh-Quan Tran
AZAhmed S. Zamzam
Ahmed S. Zamzam
PNPhuong H. Nguyen
Phuong H. Nguyen
APA.J.M. Pemen
A.J.M. Pemen
The development of active distribution grids requires more accurate and lower computational cost state estimation. In this paper, the authors investigate a decentralized learning-based distribution system state estimation (DSSE) approach for large distribution grids. The proposed approach decomposes the feeder-level DSSE into subarea-level estimation problems that can be solved independently. The proposed method is decentralized pruned physics-aware neural network (D-P2N2). The physical grid topology is used to parsimoniously design the connections between different hidden layers of the D-P2N2. Monte Carlo simulations based on one-year of load consumption data collected from smart meters for a three-phase distribution system power flow are developed to generate the measurement and voltage state data. The IEEE 123-node system is selected as the test network to benchmark the proposed algorithm against the classic weighted least squares and state-of-the-art learning-based DSSE approaches. Numerical results show that the D-P2N2 outperforms the state-of-the-art methods in terms of estimation accuracy and computational efficiency.

28 June 2021
Verified
Conference Paper
Closed access
Minh-Quan TranMinh-Quan Tran
Minh-Quan Tran
AZAhmed S. Zamzam
Ahmed S. Zamzam
PNPhuong H. Nguyen
Phuong H. Nguyen
Realizing complete observability in the three-phase distribution system remains a challenge that hinders the implementation of classic state estimation algorithms. In this paper, a new method, called the pruned physics-aware neural network (P2N2), is developed to improve the voltage estimation accuracy in the distribution system. The method relies on the physical grid topology, which is used to design the connections between different hidden layers of a neural network model. To verify the proposed method, a numerical simulation based on one- year smart meter data of load consumptions for three-phase power flow is developed to generate the measurement and voltage state data. The IEEE 123-node system is selected as the test network to benchmark the proposed algorithm against the classic weighted least squares (WLS). Numerical results show that P2N2 outperforms WLS in terms of data redundancy and estimation accuracy.

9 May 2022
Verified
Conference Paper
Open access
TNThien-An Nguyen-Huu
Thien-An Nguyen-Huu
TTTrung Thai Tran
Trung Thai Tran
Minh-Quan TranMinh-Quan Tran
Minh-Quan Tran
PNPhuong H. Nguyen
Phuong H. Nguyen
JSJg Slootweg
Jg Slootweg
Increasing the integration of distributed energy resources (DERs) requires an orchestration of the existing centralized management system used for the electricity grid and the emerging distributed ones for local energy communities (LEC). To support this orchestration, design and operation strategies of LECs needs to be analysed, based on a so-called Digital Twin (DT) platform with suitable modeling and simulation techniques. This paper presents a set of requirements needed to develop DT, thus enabling operation orchestration of LECs. Based on these specific requirements, a comprehensive review on the relevant physics-based and data-driven models will be discussed, especially focusing on the flexibility profile of LEC based on data-driven model to support the balancing reserves to the electricity grid.

16 November 2022 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
Minh-Quan TranMinh-Quan Tran
Minh-Quan Tran
TTTrung Thai Tran
Trung Thai Tran
PNPhuong H. Nguyen
Phuong H. Nguyen
GPGuus Pemen
Guus Pemen
Along with the increased installation of distributed energy resources (DER), long‐term voltage stability can be improved if proper coordination is developed between DERs and grid controllers, for example, Load Tap Changer (LTC). In most of the proposed methods, the steady‐state voltage‐sensitivity analysis has been implemented to predict the voltage state, which is the state's dynamic evolution in abnormal operations of the grid with high shares of DERs. This paper presents a system identification‐based model predictive control (MPC), which can coordinate DERs and LTC to restore the voltage to the pre‐fault condition after emergencies. First, the online voltage evolution is predicted based on the sparse identification of the nonlinear dynamics (SINDY) technique. Then, the SINDY‐based voltage prediction is combined with an adaptive MPC in the centralized controller. In addition, the nonlinear of DERs have been modeled to avoid the MPC‐based coordination jeopardizing the local constraints of DERs. The proposed method has been tested in a modified CIGRE benchmark network. Simulation results show that the dynamic voltage is effectively estimated by the SINDY method. Furthermore, the developed MPC model smoothly supports faster voltage recovering time with the least number of control actions of LTCs.

24 July 2019 in Energies
Verified
Journal Article
Open access
PDF file
Minh-Quan TranMinh-Quan Tran
Minh-Quan Tran
MINH-CHAU DINHMINH-CHAU DINH
MINH-CHAU DINH
SLSeok-Ju Lee
Seok-Ju Lee
JLJea-In Lee
Jea-In Lee
MPMinwon Park
Minwon Park
JYJongSu Yoon
JongSu Yoon
This paper presents a detailed analysis results of the effect of a thyristor-controlled series capacitor (TCSC) on subsynchronous resonance (SSR), which was first applied to a Korean power system. First, the TCSC parameters were calculated, the structure of TCSC with synchronous voltage reversal (SVR) controller was presented, and the torsional characteristics of Hanul nuclear power generator rotor were studied to investigate the natural frequency and mode shape. The test signal method was used to determine the electrical damping in the frequency range of SSR operation through an electromagnetic transient analysis program in various system configurations. The SSR phenomenon was analyzed by comparing the electrical and mechanical damping of a conventional fixed series capacitor (FSC), and the case of a TCSC installed, and the effectiveness of the TCSC without any risk of SSR was demonstrated. As a result, when installing FSC, SSR occurred under sensitive operating conditions, but SSR was prevented in the case of TCSC compensation with SVR. The results obtained in this study can be effectively applied to the installation of TCSC in real power systems.