Honglin Wang

Dr. Honglin Wang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Applied Thermal Engineering
Verified
Journal Article
Closed access
HWHonglin Wang
Honglin Wang
HBHaiquan Bi
Haiquan Bi
YZYuanlong Zhou
Yuanlong Zhou
CLCe Li
Ce Li

1 September 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
WLWenfeng Luo
Wenfeng Luo
HWHonglin Wang
Honglin Wang
YWyudong wu
yudong wu
HBhaiquan Bi
haiquan Bi
WDWeiping Ding
Weiping Ding
To effectively control the micro-pressure wave noise radiating from tunnel exits, numerical simulations were conducted to investigate the generation and propagation of such noise at the exits of high-speed metro tunnels. Large-eddy simulation was employed to obtain the near-field unsteady flow field data at the tunnel exit. The Ffowcs Williams–Hawkings (FW–H) acoustic analogy was used to predict the types of sound sources for micro-pressure wave noise. The unsteady flow field data were also utilized for finite element method acoustic analysis to calculate the far-field radiation of micro-pressure wave noise. The accuracy of the numerical methods was verified through moving model tests. The results indicate that dipole noise dominates within the micro-pressure wave noise. The tunnel's inner wall contributes most to the dipole sound sources. Dipole noise radiates outward in the form of semi-ellipsoidal waves, with energy mainly concentrated below 20 Hz and a peak frequency of 4 Hz. Furthermore, the decay of dipole noise in the direction of the tunnel exit follows a similar exponential decay pattern to that of an explosion shock wave. When the train speed exceeds 400 km/h, the human ear can distinctly perceive the sonic booms at the tunnel exit.

19 May 2022 in Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit
Verified
Journal Article
Open access
HWHonglin Wang
Honglin Wang
AVAlan E Vardy
Alan E Vardy
HBhaiquan Bi
haiquan Bi
The reflection and radiation of steep-fronted wavefronts at a tunnel exit to a deep cutting is studied and contrasted with the more usual case of radiation from over-ground portals. A well-known difference between radiation in odd and even dimensions is shown to have a significant influence on reflected wavefronts, notably causing increased distortion that complicates analyses, but that can have practical advantages when rapid changes are undesirable. Likewise, micro-pressure waves radiating from the portal into a cutting are shown to exhibit strong dispersion that does not occur in the corresponding radiation into an open terrain. In the latter case, formulae that represent the behaviour of monopoles and dipoles are commonly used to estimate conditions beyond tunnel portals, but no such simple formula exists (or is even possible) for cylindrical radiation that is characteristic of MPWs in cuttings. An important outcome of the paper is the development of an approximate relationship that predicts the maximum amplitudes of these MPWs with an accuracy that should be acceptable in engineering design, at least for initial purposes. The formula shows that peak pressure amplitudes decay much more slowly than those from an overground portal, namely varying approximately as r −0.5 compared with r −1, where r denotes the distance from the portal.

1 June 2025 in Physics of Fluids
Verified
Journal Article
Closed access
WLWenfeng Luo
Wenfeng Luo
HWHonglin Wang
Honglin Wang
ZLZhipan Li
Zhipan Li
YWyudong wu
yudong wu
HBhaiquan Bi
haiquan Bi
WDWeiping Ding
Weiping Ding
To investigate the influence of enlarged cross-section railway tunnels on high-speed trains' aerodynamic noise source characteristics, the improved delayed detached eddy simulation method is employed to calculate the unsteady flow field around the high-speed train. The aerodynamic noise source characteristics on the train's surface are predicted using the Ffowcs Williams–Hawkings acoustic model. The accuracy of the numerical method is validated through wind tunnel experiments. The results show that, across different operation stages, the unsteady flow field distribution around the high-speed train exhibits similar characteristics. Significant differences are observed in the pulsating pressure distribution on the surfaces of the train body, pantograph, and bogie; however, the dominant frequency remains constant as the train moves. While passing through the enlarged cross section, the sound pressure level at the nose of the head car, the streamlined of the tail car, and the pantograph decreases by 3.1, 10.0, and 9.1 dBA, respectively. The enlarged cross section significantly affects the radiated sound power on the train surface, with the pantograph exhibiting the highest noise radiation power density, followed by the bogie and the train body. The distribution of sound power levels on the train body and pantograph shows distinct dominant frequency characteristics. After passing through the enlarged cross section, the sound power level of the head car decreases by a maximum of 6.7%, while the tail car experiences the slightest reduction of 3.1%. The sound power level of the pantograph decreases only marginally by 3.5 dBA over the entire operation.

1 February 2023 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
YBYunfeng Bi
Yunfeng Bi
HBhaiquan Bi
haiquan Bi
HWHonglin Wang
Honglin Wang
YZYuanlong Zhou
Yuanlong Zhou
RWRuiqi Wan
Ruiqi Wan
YXYongliang Xie
Yongliang Xie
For large public buildings, a siphon drainage system facilitates good on building safety and operation. However, conventional siphon drainage systems are designed based on full pipe flow, which is suitable only under specific criteria and cannot assess the detailed flow characteristics from priming to the entire siphon formation process. In this paper, a full-size experimental platform for a single outlet siphon drainage system is proposed to research the flow characteristics of the siphon drainage. Then, a full-scale numerical model of a siphon drainage system is established and the process of the siphon drainage is simulated by the volume of fluid model. The accuracy of the numerical model is verified by comparing its results with the experimental data. Moreover, a sensitivity analysis of different pipeline structure parameters on siphon priming time is presented, which shows that a larger length and diameter of the suspension pipe and a larger riser pipe diameter prolong the siphon formation time. Finally, theoretical formulas are derived to describe the mathematical relationships between the suspension pipe length and maximum displacement and the suspension pipe length and siphon priming time.

23 November 2021 in International Journal of Ventilation
Verified
Journal Article
Closed access
YZYuanlong Zhou
Yuanlong Zhou
HWHonglin Wang
Honglin Wang
HBhaiquan Bi
haiquan Bi
Rescue station is an important part of the extra-long railway tunnel, which can provide smoke-free refuge for evacuated passengers. For the fire research of the rescue station, the influence of the burning train running on the smoke spread characteristics has not been considered in the previous studies. In this work, the influence of the train running on the fire smoke spread characteristics in the rescue station was investigated using the numerical method, and the accuracy of the numerical methodology was confirmed by the 1:20 scale model experiment. Then, the influence of the burning train running on the temperature and visibility distribution in the rescue station was analysed by dynamic and static simulation. The results demonstrate that the temperature and soot density of the smoke are low when the burning train was running in the tunnel, which makes fire detection very difficult. For the smoke spread characteristics of the rescue station, the main impact of the burning train running is visibility, and the influence time is 30 s when the heat release rate of the fire source was 15 MW. For dynamic simulation, when the burning train stops at the rescue station, the maximum heat transfer power between the smoke at the top of the tunnel and the concrete lining is 1.51 MW, accounting for 10.1% of the heat release rate of the fire source.