Yuanlong Zhou

Yuanlong Zhou


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2019 in Journal of Fire Sciences
Verified
Journal Article
Closed access
PDF file
HBhaiquan Bi
haiquan Bi
YZYuanlong Zhou
Yuanlong Zhou
HWHonglin Wang
Honglin Wang
QGQilin Gou
Qilin Gou
XLXiaoxia Liu
Xiaoxia Liu
With the rapid development of high-speed railways, safety hazards presented by train fires cannot be ignored. An effective design for protection against fire in high-speed trains is essential to ensure passenger safety. In this study, the cone calorimeter and ignition temperature tester were used to carry out combustion experiments on materials constituting the main components of the train. The heat release rate, smoke yield, CO yield, and ignition temperature of combustible materials were tested. Based on the experimental data of material combustion, a numerical model of the high-speed train carriage fire was simulated. The accuracy of the numerical simulation was verified by drawing a comparison with the full-scale train fire experiment in existing literature. The numerical simulation results revealed that when the fire source is present at the corner of the carriage end door, the fire develops to the maximum possible extent in approximately 25 min, with a peak heat release rate of approximately 38.4 MW. Increase in the carriage fire heat release rate and breakage of windows occur almost simultaneously. Improvement of the fireproof performance of windows can inhibit and delay the carriage fire development. For the flashover of carriage fire, the spread speed of the flashover area in the longitudinal direction inside the carriage is approximately 1.9 m/s. The end door area furthest from the fire source in the carriage has strong flashover, while the flashover in other areas is weak.

1 February 2023 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
YBYunfeng Bi
Yunfeng Bi
HBhaiquan Bi
haiquan Bi
HWHonglin Wang
Honglin Wang
YZYuanlong Zhou
Yuanlong Zhou
RWRuiqi Wan
Ruiqi Wan
YXYongliang Xie
Yongliang Xie
For large public buildings, a siphon drainage system facilitates good on building safety and operation. However, conventional siphon drainage systems are designed based on full pipe flow, which is suitable only under specific criteria and cannot assess the detailed flow characteristics from priming to the entire siphon formation process. In this paper, a full-size experimental platform for a single outlet siphon drainage system is proposed to research the flow characteristics of the siphon drainage. Then, a full-scale numerical model of a siphon drainage system is established and the process of the siphon drainage is simulated by the volume of fluid model. The accuracy of the numerical model is verified by comparing its results with the experimental data. Moreover, a sensitivity analysis of different pipeline structure parameters on siphon priming time is presented, which shows that a larger length and diameter of the suspension pipe and a larger riser pipe diameter prolong the siphon formation time. Finally, theoretical formulas are derived to describe the mathematical relationships between the suspension pipe length and maximum displacement and the suspension pipe length and siphon priming time.

23 November 2021 in International Journal of Ventilation
Verified
Journal Article
Closed access
YZYuanlong Zhou
Yuanlong Zhou
HWHonglin Wang
Honglin Wang
HBhaiquan Bi
haiquan Bi
Rescue station is an important part of the extra-long railway tunnel, which can provide smoke-free refuge for evacuated passengers. For the fire research of the rescue station, the influence of the burning train running on the smoke spread characteristics has not been considered in the previous studies. In this work, the influence of the train running on the fire smoke spread characteristics in the rescue station was investigated using the numerical method, and the accuracy of the numerical methodology was confirmed by the 1:20 scale model experiment. Then, the influence of the burning train running on the temperature and visibility distribution in the rescue station was analysed by dynamic and static simulation. The results demonstrate that the temperature and soot density of the smoke are low when the burning train was running in the tunnel, which makes fire detection very difficult. For the smoke spread characteristics of the rescue station, the main impact of the burning train running is visibility, and the influence time is 30 s when the heat release rate of the fire source was 15 MW. For dynamic simulation, when the burning train stops at the rescue station, the maximum heat transfer power between the smoke at the top of the tunnel and the concrete lining is 1.51 MW, accounting for 10.1% of the heat release rate of the fire source.

7 January 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
JWJing Wang
Jing Wang
HBhaiquan Bi
haiquan Bi
YZYuanlong Zhou
Yuanlong Zhou
BLBo Lei
Bo Lei
ZMZhicheng Mu
Zhicheng Mu
Modern high-speed train compartments contain intricate internal configurations. In the event of a fire emergency, the propagation velocity of flames through the passenger cabin is determined by multiple factors, including compartment design, ignition source characteristics, and airflow conditions. This study employed numerical simulation approaches to investigate the effects of fire source power, fire source location, and longitudinal ventilation velocity on the rate of flame progression. The simulation outcomes reveal that, under forward ventilation conditions, the magnitude of fire power has a minimal influence on flame propagation speed. However, stronger fire sources lead to earlier initiation of flame spread along the carriage. Central positioning of the ignition source results in bidirectional flame movement toward both ends of the carriage, with faster propagation rates than those of fires originating at the extremities. Longitudinal airflow patterns significantly. When the airflow speed within the tunnel remains below 3 meters per second, the impact of longitudinal ventilation on fire propagation speed in the train is minimal under forward ventilation conditions. Conversely, in reverse-ventilation scenarios, the rate of flame advancement shows a positive correlation with increasing ventilation speed. Nevertheless, once tunnel ventilation velocities exceed 3 m/s, combustion propagation within high-speed rail carriages becomes impossible due to intact windows, which create oxygen-deficient conditions that prevent the development of fire.

1 August 2026 in Physics of Fluids
Verified
Journal Article
Closed access
YBYunfeng Bi
Yunfeng Bi
HBhaiquan Bi
haiquan Bi
HWHonglin Wang
Honglin Wang
YZYuanlong Zhou
Yuanlong Zhou
ZWZhanhao Wang
Zhanhao Wang
NZNan Zhang
Nan Zhang
The evacuated tube maglev transportation (ETMT) system offers advantages in terms of high speed, efficiency, and safety and has emerged as a crucial development trend in the future transportation sector. Nevertheless, the special enclosed environment renders the thermal environment within the ETMT System highly complex and even endangers the security of the operation. Thus, investigating the formation mechanisms of aerodynamic heat and the mitigation strategies discussed herein provides technical support for engineering applications. The subject of this paper is to analyze the aerodynamic heat, that is, as presented by the waves and temperature changes within the tube, using the shear stress transport k–ω model, in conjunction with the dynamic mesh technique. The cardinal result is that the distance between the train and the normal shock waves increases linearly as the train's operating time extends. Besides, an increase in the train's speed led to a reduction in the velocity difference between the train and the air within the tube. Thereby improving the kinetic energy transfer efficiency and amplifies the temperature gradient variations in the choked flow ahead of the train. In addition, the mitigation strategies can reduce 21.5 °C in the choked flow region and shorten the shock wavelength at the rear of the train.

13 September 2025 in Journal of Central South University
Verified
Journal Article
Closed access
PDF file
XZXu Zhang
Xu Zhang
YZYuanlong Zhou
Yuanlong Zhou
HBHai-Quan Bi
Hai-Quan Bi
HWHong-Lin Wang
Hong-Lin Wang
NYNan-Yang Yu
Nan-Yang Yu