Martin Grimmer

Mr. Martin Grimmer

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2017 in Science Robotics
Verified
Journal Article
Closed access
PDF file
BQB. T. Quinlivan
B. T. Quinlivan
SLS. Lee
S. Lee
PMP. Malcolm
P. Malcolm
Denise Martineli RossiDenise Martineli Rossi
Denise Martineli Rossi
MGMartin Grimmer
Martin Grimmer
CWC. J. Walsh
C. J. Walsh
Evaluation of a soft exosuit designed to reduce metabolic requirements during walking.

3 January 2019 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
MGMartin Grimmer
Martin Grimmer
RRRobert Riener
Robert Riener
CWConor James Walsh
Conor James Walsh
ASAndré Seyfarth
André Seyfarth
Background: Physical and functional losses due to aging and diseases decrease human mobility, independence, and quality of life. This study is aimed at summarizing and quantifying these losses in order to motivate solutions to overcome them with a special focus on the possibilities by using lower limb exoskeletons.Methods: A narrative literature review was performed to determine a broad range of mobility-related physical and functional measures that are affected by aging and selected cardiovascular, respiratory, musculoskeletal, and neurological diseases.Results: The study identified that decreases in limb maximum muscle force and power (33% and 49%, respectively, 25–75 yrs) and in maximum oxygen consumption (40%, 20–80 yrs) occur for older adults compared to young adults. Reaction times more than double (18–90 yrs) and losses in the visual, vestibular, and somatosensory systems were reported. Additionally, we found decreases in steps per day (75%, 60–85 yrs), maximum walking speed (24% 25–75 yrs), and maximum six-minute and self-selected walking speed (38% and 21%, respectively, 20–85 yrs), while we found increases in the number of falls relative to the number of steps per day (800%), injuries due to falls (472%, 30–90 yrs) and deaths caused by fall (4000%, 65–90 yrs). Measures were identified to be worse for individuals with impaired mobility. Additional detrimental effects identified for them were the loss of upright standing and locomotion, freezing in movement, joint stress, pain, and changes in gait patterns.Discussion: This review shows that aging and chronic conditions result in wide-ranging losses in physical and sensory capabilities. While the impact of these losses are relatively modest for level walking, they become limiting during more demanding tasks such as walking on inclined ground, climbing stairs, or walking over longer periods, and especially when coupled with a debilitating disease. As the physical and functional parameters are closely related, we believe that lost functional capabilities can be indirectly improved by training of the physical capabilities. However, assistive devices can supplement the lost functional capabilities directly by compensating for losses with propulsion, weight support, and balance support.Conclusions: Exoskeletons are a new generation of assistive devices that have the potential to provide both, training capabilities and functional compensation, to enhance human mobility.

19 December 2016 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
MWMichael Windrich
Michael Windrich
MGMartin Grimmer
Martin Grimmer
OCOliver Christ
Oliver Christ
Stephan RinderknechtStephan Rinderknecht
Stephan Rinderknecht
PBPhilipp Beckerle
Philipp Beckerle
This paper presents a review on design issues and solutions found in active lower limb prostheses. This review is based on a systematic literature search with a methodical search strategy. The search was carried out across four major technical databases and the retrieved records were screened for their relevance. A total of 21 different active prostheses, including 8 above-knee, 9 below-knee and 4 combined knee-ankle prostheses were identified. While an active prosthesis may help to restore the functional performance of an amputee, the requirements regarding the actuation unit as well as for the control system are high and the development becomes a challenging task. Regarding mechanical design and the actuation unit high force/torque delivery, high efficiency, low size and low weight are conflicting goals. The actuation principle and variable impedance actuators are discussed. The control system is paramount for a “natural functioning” of the prosthesis. The control system has to enable locomotion and should react to the amputee’s intent. For this, multi-level control approaches are reviewed.

27 October 2017 in Frontiers in Neurorobotics
Verified
Journal Article
Open access
KSKai Schmidt
Kai Schmidt
JDJaime E. Duarte
Jaime E. Duarte
MGMartin Grimmer
Martin Grimmer
ASAlejandro Sancho-Puchades
Alejandro Sancho-Puchades
HWHaiqi Wei
Haiqi Wei
RRRobert Riener
Robert Riener
Muscle weakness—which can result from neurological injuries, genetic disorders, or typical aging—can affect a person’s mobility and quality of life. For many people with muscle weakness, assistive devices provide the means to regain mobility and independence. These devices range from well-established technology, such as wheelchairs, to newer technologies, such as exoskeletons and exosuits. For assistive devices to be used in everyday life, they must provide assistance across activities of daily living (ADLs) in an unobtrusive manner. This article introduces the Myosuit, a soft, wearable device designed to provide continuous assistance at the hip and knee joint when working with and against gravity in ADLs. This robotic device combines active and passive elements with a closed-loop force controller designed to behave like an external muscle (exomuscle) and deliver gravity compensation to the user. At 4.1 kg (4.6 kg with batteries), the Myosuit is one of the lightest untethered devices capable of delivering gravity support to the user’s knee and hip joints. This article presents the design and control principles of the Myosuit. It describes the textile interface, tendon actuators, and a bi-articular, synergy-based approach for continuous assistance. The assistive controller, based on bi-articular force assistance, was tested with a single subject who performed sitting transfers, one of the most gravity-intensive ADLs. The results show that the control concept can successfully identify changes in the posture and assist hip and knee extension with up to 26% of the natural knee moment and up to 35% of the knee power. We conclude that the Myosuit's novel approach to assistance using a bi-articular architecture, in combination with the posture-based force controller, can effectively assist its users in gravity-intensive ADLs, such as sitting transfers.

1 May 2012
Verified
Conference Paper
Closed access
MGMartin Grimmer
Martin Grimmer
MEMahdy Eslamy
Mahdy Eslamy
SGStefan Gliech
Stefan Gliech
ASAndre Seyfarth
Andre Seyfarth
Elastic elements in prosthetic devices can help to reduce peak power (PP) and energy requirements (ER) for the actuators. Calculations showed that it is impossible with current commercial motor technology to mimic human ankle behavior in detail for higher walking and running speeds with single motor solutions using a Serial Elastic Actuator (SEA). Concerning this result we checked the requirements of a parallel elastic actuator (PEA) and a combination of serial and parallel (SE+PEA) springs. We found that a PEA can reduce PP additionally in comparison to the SEA by pre-loading the spring in the flight phase. This reduces also peak torque. But this loading needs additional energy so that the ER increase in comparison to the SEA. The SE+PEA concept can further decrease PP. With that, the ER are less than the PEA but higher than for the SEA. The results show less benefit for the PEA and the SE+PEA when a constant stiffness and a fixed parallel spring slack length is used for both gaits and all speeds. All concepts show that mimicking human ankle joint behavior in running and walking at higher speeds is still challenging for single motor devices.

24 July 2019 in Frontiers in Neurorobotics
Verified
Journal Article
Open access
PDF file
MGMartin Grimmer
Martin Grimmer
KSKai Schmidt
Kai Schmidt
JDJaime E. Duarte
Jaime E. Duarte
LNLukas Neuner
Lukas Neuner
GKGleb Koginov
Gleb Koginov
RRRobert Riener
Robert Riener
Lower limb exoskeletons require the correct support magnitude and timing to achieve user assistance. This study evaluated whether the sign of the angular velocity of lower limb segments can be used to determine the timing of the stance and the swing phase during walking. We assumed that stance phase is characterized by a positive, swing phase by a negative angular velocity. Thus, the transitions can be used to also identify heel-strike and toe-off. Thirteen subjects without gait impairments walked on a treadmill at speeds between 0.5 and 2.1 m/s on level ground and inclinations between −10 and +10°. Kinematic and kinetic data was measured simultaneously from an optical motion capture system, force plates, and five inertial measurement units (IMUs). These recordings were used to compute the angular velocities of four lower limb segments: two biological (thigh, shank) and two virtual that were geometrical projections of the biological segments (virtual leg, virtual extended leg). We analyzed the reliability (two sign changes of the angular velocity per stride) and the accuracy (offset in timing between sign change and ground reaction force based timing) of the virtual and biological segments for detecting the gait phases stance and swing. The motion capture data revealed that virtual limb segments seem superior to the biological limb segments in the reliability of stance and swing detection. However, increased signal noise when using the IMUs required additional rule sets for reliable stance and swing detection. With IMUs, the biological shank segment had the least variability in accuracy. The IMU-based heel-strike events of the shank and both virtual segment were slightly early (3.3–4.8% of the gait cycle) compared to the ground reaction force-based timing. Toe-off event timing showed more variability (9.0% too early to 7.3% too late) between the segments and changed with walking speed. The results show that the detection of the heel-strike, and thus stance phase, based on IMU angular velocity is possible for different segments when additional rule sets are included. Further work is required to improve the timing accuracy for the toe-off detection (swing).