Pavel Shlepakov

Dr. Pavel Shlepakov


Research Focus & Metrics

Representative Publications

View All Publications
18 March 2021 in Actuators
Verified
Journal Article
Open access
PDF file
Ilia UvarovIlia Uvarov
Ilia Uvarov
PSPavel Shlepakov
Pavel Shlepakov
AMArtem E. Melenev
Artem E. Melenev
KMKechun Ma
Kechun Ma
Vitaly SvetovoyVitaly Svetovoy
Vitaly Svetovoy
GKGijs Krijnen
Gijs Krijnen
Microfluidic devices providing an accurate delivery of fluids at required rates are of considerable interest, especially for the biomedical field. The progress is limited by the lack of micropumps, which are compact, have high performance, and are compatible with standard microfabrication. This paper describes a micropump based on a new driving principle. The pump contains three membrane actuators operating peristaltically. The actuators are driven by nanobubbles of hydrogen and oxygen, which are generated in the chamber by a series of short voltage pulses of alternating polarity applied to the electrodes. This process guaranties the response time of the actuators to be much shorter than that of any other electrochemical device. The main part of the pump has a size of about 3 mm, which is an order of magnitude smaller in comparison with conventional micropumps. The pump is fabricated in glass and silicon wafers using standard cleanroom processes. The channels are formed in SU-8 photoresist and the membrane is made of SiNx. The channels are sealed by two processes of bonding between SU-8 and SiNx. Functionality of the channels and membranes is demonstrated. A defect of electrodes related to the lift-off fabrication procedure did not allow a demonstration of the pumping process although a flow rate of 1.5 µL/min and dosage accuracy of 0.25 nL are expected. The working characteristics of the pump make it attractive for the use in portable drug delivery systems, but the fabrication technology must be improved.

17 July 2024 in Advanced Materials Technologies
Verified
Journal Article
Closed access
Ilia UvarovIlia Uvarov
Ilia Uvarov
PSPavel Shlepakov
Pavel Shlepakov
Vitaly SvetovoyVitaly Svetovoy
Vitaly Svetovoy

1 December 2020 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
PSPavel Shlepakov
Pavel Shlepakov
IUI V Uvarov
I V Uvarov
VNV V Naumov
V V Naumov
Vitaly SvetovoyVitaly Svetovoy
Vitaly Svetovoy
Electrochemical actuators are promising candidates for implementation in various microfluidic systems, but they suffer from a very long response time due to slow gas recombination. Water electrolysis performed by short voltage pulses of alternating polarity (AP) reduces the response time by several orders of magnitude. This process, however, results in a fast degradation of electrodes. It is important to find a material, which is able to withstand the AP operation without significant degradation. In this work the electrodes made of six metals are fabricated and tested. The current flowing through the cell, the threshold voltage for the explosive operation, and the wear of the electrodes are analyzed and compared.

1 June 2023 in Russian Microelectronics
Verified
Journal Article
Closed access
PDF file
Ilia UvarovIlia Uvarov
Ilia Uvarov
PSPavel Shlepakov
Pavel Shlepakov
AAA. M. Abramychev
A. M. Abramychev
Vitaly SvetovoyVitaly Svetovoy
Vitaly Svetovoy
Microfluidic devices are capable of precise drug delivery to the human body. For this purpose, they must be equipped with a compact pump that provides a high flow rate and precise dosing. In this paper, we present a micropump based on a fast electrochemical actuator that meets these requirements. It contains three actuators operating in the peristaltic mode. The device is fabricated from glass and silicon wafers using the standard microfabrication processes. The working part of the pump has a size of about 3 mm3, which is an order of magnitude smaller than other types of diaphragm pumps. The small size of the actuators ensures ultrahigh liquid dosing accuracy of 0.14 nL. At the same time, the high frequency of operation of the actuators makes it possible to develop a specific pumping velocity comparable to other types of pumps.

1 December 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
PSPavel Shlepakov
Pavel Shlepakov
Ilia UvarovIlia Uvarov
Ilia Uvarov
VNV V Naumov
V V Naumov
AMA E Melenev
A E Melenev
Vitaly SvetovoyVitaly Svetovoy
Vitaly Svetovoy
Electrochemical membrane actuator based on water electrolysis of alternating polarity (AP) was demonstrated recently. It operates several orders of magnitude faster than the devices working on conventional DC electrolysis. However, extremely high current density of the AP process leads to the fast degradation of the electrodes. Titanium electrodes demonstrate the best durability, but they oxidize during operation that reduces the gas production. Proper design can increase the efficiency of the electrodes and slow the degradation down. In this work, four typical layouts are fabricated and tested in the AP electrolysis. Current flowing through the cell, threshold voltage for the explosive operation and wear of the electrodes are analyzed and compared.

1 May 2023 in Микроэлектроника
Verified
Journal Article
Closed access
PDF file
Ilia UvarovIlia Uvarov
Ilia Uvarov
PSPavel Shlepakov
Pavel Shlepakov
AAA. M. Abramychev
A. M. Abramychev
VSV. B. Svetovoy
V. B. Svetovoy
Fast Electrochemical Micropump for Portable Drug Delivery Module Быстрый электрохимический микронасос для портативного модуля доставки лекарств