A comparison of fuzzy self‐tuning (FST), sliding mode control (SMC) and conventional proportional–integral (PI) control methods is performed under unbalanced grid conditions using a bridgeless power factor correction (PFC) converter. The bridgeless PFC converter operates the correction of AC line current to obtain a DC output voltage without full bridge rectifier based on these control methods. These control methods generate the duty cycles to provide higher unity power factor and lower total harmonic distortion of input current, even if AC line voltage is distorted. This study focuses on the performance analysis of FST and SMC methods adaptation to the input current for the bridgeless PFC converter and comparing with the conventional PI controller. Although the SMC method is only used in the current control loop, the FST method is used in both current and voltage control loops for eliminating harmonics of input current and regulating of output voltage. The performance of control methods is evaluated with a TMS320F2812 digital signal processor. The simulation and experimental results are compatible with the limits for harmonic current emissions, IEC 61000‐3‐2 and show that the FST and SMC are better than the conventional PI control method and FST is superior to the SMC.
13 December 2018 in International Journal of Electronics
In the last decade, the impedance source networks has been vastly used in electrical power conversion such as in electric vehicles, industrial machines, medical systems and avionics, with considerable efficiency improvements. In this study, two new impedance source network topologies for inverter applications have been designed and tested. The first one is a one-cell switched inductor (SL), the second is a two-cell switched inductor (X-SL) combined with the classical Z-source inverter (ZSI). This novel combination allows the switched inductor to store the unused source energy in the interval when the source separates from the ZSI network during the shoot-through zero state. The design is generalized by adding multiple branches of series inductors and diodes which further improve the circuit performance. The National Instrument Multisim program is used for the simulations of the new topologies. Both of the proposed topologies, SL combined with classical ZSI (SL&ZSI) and X-SL combined with classical ZSI (X-SL&ZSI) are tested with specific inductance and capacitance values. Major improvements are observed in the Boost Factor (BF) and the elimination of the start-up inrush current for both topologies, compared to the classical ZSI scheme. Furthermore in both topologies, a significant reduction in the capacitor stress levels is obtained.
15 September 2018 in Journal of Intelligent & Fuzzy Systems: Applications in Engineering and Technology
In this study, the performance analysis of Fuzzy Self Tuning (FST) control method for Bridgeless Power Factor Correction (PFC) converter is proposed. The Bridgeless PFC converter based on FST method operates AC line rectification to result in DC output voltage without full-bridge rectifier. The proposed method generates the duty cycles to provide higher Unity Power Factor (UPF) and lower Total Harmonic Distortion (THD) of input current, even if AC line voltage consists of harmonics. Although Ziegler-Nichols method is very important to tune the coefficients of PI control method, it cannot guarantee to be always effective. For this reason, this study investigates the design of FST control method that tunes the coefficients of K p , and K i gains that are used into inner and outer control loops. These parameters are self-tuned to make them more general, to achieve minimum steady-state error, and to improve the dynamic behavior such as overshoot. Performance of proposed system was implemented for 1 kW Bridgeless PFC converter board with a TMS320F2812 DSP. The simulation and experimental results are compatible with the limits for harmonic current emissions, IEC 61000-3-2 and show that the proposed method is better than traditional ones.
In this study, the analysis and simulation studies on Single Ended Primary Inductor Converter (SEPIC) technology used as a energy source in computer systems are proposed. In computer systems, these converters are inevitable and used widely. To step up or step down voltage, different type circuit topologies are available (Buck, Boost, Cuk etc.). While buck converter can only decrease the voltage, boost converter steps up the voltage. Cuk and SEPIC can be used both process. Some issues like large amounts of electrical stress on the buck, boost and Cuk converter components, the main board power supplies can be overheating. Also negative regulated output voltage is obtained in these converters. These problems are not seen in SEPIC converters. Also they provide to wide operation with high efficiency. By controlling of the gate signal of switching devices, desired output voltage is obtained as positive regulated in SEPIC converter. This study proposed a development of PI control method that provides the proper dynamic and static performance compared to other methods. The simulation and implementation of SEPIC converter is simulated in Matlab/Simulink software.
20 December 2024 in International Advanced Researches and Engineering Journal
Studies in literature and the increasing trend of electrification show that electric vehicles (EVs) will become more widespread in the future. However, the growing demand for EV chargers causes an overload on the grid. Furthermore, EV chargers generate power factor distortion and harmonics, which contaminate the grid and lower the quality of power. Therefore, power factor correction (PFC) is applied by EV chargers to mitigate the harmonics. As defined in the IEC 61000-3-2 standard, the total harmonic distortion (THD) shall be less than 5%. In this study, a better PFC operation is achieved with the proposed bridgeless isolated single ended primary inductor converter (BL SEPIC) topology as an EV charger instead of conventional converter topologies that have diode bridge rectifiers (DBR). Also, the study has better THD outputs as compared with the similar bridgeless (BL) topologies in literature thanks to the simulated control methods of the proportion-integration (PI) and fuzzy control. Moreover, these control methods are compared with each other in terms of THD suppression performance, stability, robustness, and computational effort. The results showed that the fuzzy controller has advantages of stability and robustness against the transient conditions, input voltages and load changes for THD suppression while the PI controller has better THD results only for steady state operation with nominal input voltage and full load conditions. The implemented PI and fuzzy controllers are simulated in a MATLAB Simulink environment.