Markus Bainschab

Dr. Markus Bainschab

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2016 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
RRRoland Resel
Roland Resel
MBMarkus Bainschab
Markus Bainschab
APAlexander Pichler
Alexander Pichler
TDTheo Dingemans
Theo Dingemans
CSClemens Simbrunner
Clemens Simbrunner
ISIngo Salzmann
Ingo Salzmann
Dynamical scattering effects are observed in grazing-incidence X-ray diffraction experiments using an organic thin film of 2,2′:6′,2′′-ternaphthalene grown on oxidized silicon as substrate. Here, a splitting of all Bragg peaks in the out-of-plane direction (z-direction) has been observed, the magnitude of which depends both on the incidence angle of the primary beam and the out-of-plane angle of the scattered beam. The incident angle was varied between 0.09° and 0.25° for synchrotron radiation of 10.5 keV. This study reveals comparable intensities of the split peaks with a maximum for incidence angles close to the critical angle of total external reflection of the substrate. This observation is rationalized by two different scattering pathways resulting in diffraction peaks at different positions at the detector. In order to minimize the splitting, the data suggest either using incident angles well below the critical angle of total reflection or angles well above, which sufficiently attenuates the contributions from the second scattering path. This study highlights that the refraction of X-rays in (organic) thin films has to be corrected accordingly to allow for the determination of peak positions with sufficient accuracy. Based thereon, a reliable determination of the lattice constants becomes feasible, which is required for crystallographic structure solutions from thin films.

27 October 2023 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
JPJaka Pribošek
Jaka Pribošek
MBMarkus Bainschab
Markus Bainschab
TSTakashi Sasaki
Takashi Sasaki
Recent advances brought the performance of MEMS-based varifocal mirrors to levels comparable to conventional ultra-high-speed focusing devices. Varifocal mirrors are becoming capable of high axial resolution exceeding 300 resolvable planes, can achieve microsecond response times, continuous operation above several hundred kHz, and can be designed to combine focusing with lateral steering in a single-chip device. This survey summarizes the past 50 years of scientific progress in varifocal MEMS mirrors, providing the most comprehensive study in this field to date. We introduce a novel figure of merit for varifocal mirrors on the basis of which we evaluate and compare nearly all reported devices from the literature. At the forefront of this review is the analysis of the advantages and shortcomings of various actuation technologies, as well as a systematic study of methods reported to enhance the focusing performance in terms of speed, resolution, and shape fidelity. We believe this analysis will fuel the future technological development of next-generation varifocal mirrors reaching the axial resolution of 1000 resolvable planes.

9 August 2016 in The Journal of Physical Chemistry A
Verified
Journal Article
Closed access
PMPaul Maierhofer
Paul Maierhofer
MBMarkus Bainschab
Markus Bainschab
BTBernhard Thaler
Bernhard Thaler
PHPascal Heim
Pascal Heim
WEWolfgang E Ernst
Wolfgang E Ernst
MKMarkus Koch
Markus Koch

20 November 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MBMarkus Bainschab
Markus Bainschab
SMSampsa Martikainen
Sampsa Martikainen
JKJorma Keskinen
Jorma Keskinen
ABAlexander Bergmann
Alexander Bergmann
Panu KarjalainenPanu Karjalainen
Panu Karjalainen
An aerosol gas exchange system (AGES) for nanoparticle sampling at elevated temperatures was developed, modeled, and further characterized with laboratory tests with respect to gas exchange efficiency and particle losses. The model describing the gas exchange was first verified with oxygen and later studied with several inert gases having molecular masses between 18 and 135 u. The exchange rate of the lightest compounds exceeds 90% efficiency at the flow rates used. In order to reach similarly high removal efficiencies for larger molecules, the residence time in the AGES has to be increased. The removal of sticky gases was studied with gaseous sulfuric acid. Results agreed with the model where the boundary condition is zero concentration on the wall. The AGES exhibits very limited particle losses (<5%) for mono-disperse 6 nm particles. Furthermore, diffusional losses for particles down to 1.2 nm were measured utilizing polydisperse aerosol. The experimental findings are in good agreement with the model derived. As both, gas exchange rate and particle losses, rely on the physical effect of diffusion, an optimization for enhanced gas exchange efficiency will come at the cost of increased diffusional particle losses. The presented model can be used as a tool to redesign and optimize the AGES for a desired application. With an application targeted design, particle dilution can be avoided, which can lead to improved results in many fields of aerosol measurement.

3 April 2024 in Proceedings
Verified
Conference Paper
Open access
PDF file
CFClement Fleury
Clement Fleury
MBMarkus Bainschab
Markus Bainschab
GMGianluca Mendicino
Gianluca Mendicino
RCRoberto Carminati
Roberto Carminati
PTPooja Thakkar
Pooja Thakkar
APAdrien Piot
Adrien Piot
We demonstrate an experimental assessment of a high-Q, high-angle piezoelectric (2 µm PZT) MEMS scanning micromirror featuring distributed backside reinforcement, suitable for applications demanding energy-efficient and high-quality image projection. Frequency response measurements at 10 different vacuum levels ranging from atmospheric pressure to 10−6 mbar allow for the quantitative separation of damping mechanisms (air and structural). Stroboscopic digital holographic microscopy was used to assess the static and dynamic deformation of the mirror surface. The experimental results are in good agreement with simulations and models.

22 May 2020 in Journal of Visualized Experiments
Verified
Journal Article
Open access
PDF file
MBMarkus Bainschab
Markus Bainschab
LLLukas Landl
Lukas Landl
JAJon Andersson
Jon Andersson
AMAthanasios Mamakos
Athanasios Mamakos
SHStefan Hausberger
Stefan Hausberger
ABAlexander Bergmann
Alexander Bergmann
The current particle size threshold of the European Particle Number (PN) emission standards is 23 nm. This threshold could change because future combustion engine vehicle technology may emit large amounts of sub-23 nm particles. The Horizon 2020 funded project DownToTen (DTT) developed a sampling and measurement method to characterize particle emissions in this currently unregulated size range. A PN measurement system was developed based on an extensive review of the literature and laboratory experiments testing a variety of PN measurement and sampling approaches. The measurement system developed is characterized by high particle penetration and versatility, which enables the assessment of primary particles, delayed primary particles, and secondary aerosols, starting from a few nanometers in diameter. This paper provides instruction on how to install and operate this Portable Emission Measurement System (PEMS) for Real Drive Emissions (RDE) measurements and assess particle number emissions below the current legislative limit of 23 nm.