Siyuan Xie

Dr. Siyuan Xie

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2023 in Journal of the American Ceramic Society
Verified
Journal Article
Closed access
XHXiao He
Xiao He
YCYuhui Chen
Yuhui Chen
CXChenglong Xia
Chenglong Xia
KMKamran Muhammad
Kamran Muhammad
ZSZahra Duaa Syeda
Zahra Duaa Syeda
LLLing Li
Ling Li

15 January 2020 in Cardiology in the Young
Verified
Journal Article
Closed access
PDF file
WZWeizhi Zhang
Weizhi Zhang
SXSiyuan Xie
Siyuan Xie
DHDing Han
Ding Han
JHJiapeng Huang
Jiapeng Huang
COChuan Ou-Yang
Chuan Ou-Yang
JLJiakai Lu
Jiakai Lu
Background: Ventilation-associated changes in blood carbon dioxide levels are associated with various physiological changes in infants undergoing surgery. Studies on the effects of mechanical ventilation on cerebral haemodynamics especially for infants with CHD are scarce.Aim: This study was done to compare the changes in regional cerebral oxygen saturation and cerebral blood flow velocity when the end-tidal carbon dioxide partial pressure changed during different minute ventilation settings in infants undergoing ventricular septal defect repair.Methods: A total of 67 patients less than 1 year old with ventricular septal defect were enrolled, and 65 patients (age: 6.7 ± 3.4 months, weight: 6.4 ± 1.5 kg) were studied. After anaesthesia induction and endotracheal intubation, the same mechanical ventilation mode (The fraction of inspired oxygen was 50%, and the inspiratory-to-expiratory ratio was 1:1.5.) was adopted. The end-tidal carbon dioxide partial pressure of 30 mmHg (T1), 35 mmHg (T2), 40 mmHg (T3), or 45 mmHg (T4) were obtained, respectively, by adjusting tidal volume and respiratory rate. Minute ventilation per kilogram was calculated by the formula: minute ventilation per kilogram = tidal volume * respiratory rate/kg. Regional cerebral oxygen saturation was monitored by real-time near-infrared spectroscopy. Cerebral blood flow velocity (systolic flow velocity, end-diastolic flow velocity, and mean flow velocity), pulsatility index, and resistance index were measured intermittently by transcranial Doppler. Systolic pressure, diastolic pressure, stroke volume index, and cardiac index were recorded using the pressure recording analytical method.Results: As the end-tidal carbon dioxide partial pressure increased from 30 to 45 mmHg, regional cerebral oxygen saturation increased significantly from 69 ± 5% to 79 ± 4% (p < 0.001). Cerebral blood flow velocity (systolic flow velocity, end-diastolic flow velocity, and mean flow velocity) increased linearly, while pulsatility index and resistance index decreased linearly from T1 (systolic flow velocity, 84 ± 19 cm/second; end-diastolic flow velocity, 14 ± 4 cm/second; mean flow velocity, 36 ± 10 cm/second; pulsatility index, 2.13 ± 0.59; resistance index, 0.84 ± 0.12) to T4 (systolic flow velocity, 113 ± 22 cm/second; end-diastolic flow velocity, 31 ± 6 cm/second; mean flow velocity, 58 ± 11 cm/second; pulsatility index, 1.44 ± 0.34; resistance index, 0.72 ± 0.07) (p < 0.001). There were significant differences in changes of systolic flow velocity, end-diastolic flow velocity, mean flow velocity, pulsatility index, and resistance index as the end-tidal carbon dioxide partial pressure increased from 30 to 45 mmHg between subgroups of infants ≤6 and infants >6 months, while the changes of regional cerebral oxygen saturation between subgroups were not statistically different. Regional cerebral oxygen saturation and cerebral blood flow velocity (systolic flow velocity, end-diastolic flow velocity, and mean flow velocity) were negatively correlated with minute ventilation per kilogram (r = −0.538, r = −0.379, r = −0.504, r = −0.505, p < 0.001). Pulsatility index and resistance index were positively related to minute ventilation per kilogram (r = 0.464, r = 0.439, p < 0.001). The diastolic pressure was significantly reduced from T1 (41 ± 7 mmHg) to T4 (37 ± 6 mmHg) (p < 0.001). There were no significant differences in systolic pressure, stroke volume index, and cardiac index with the change of end-tidal carbon dioxide partial pressure from T1 to T4 (p = 0.063, p = 0.382, p = 0.165, p > 0.05).Conclusion: A relative low minute ventilation strategy increases regional cerebral oxygen saturation and cerebral blood flow, which may improve cerebral oxygenation and brain perfusion in infants undergoing ventricular septal defect repair.

9 December 2022 in Medicine
Verified
Journal Article
Open access
SXSiyuan Xie
Siyuan Xie
DHDing Han
Ding Han
GCGang Chen
Gang Chen
SPShou-Dong Pan
Shou-Dong Pan
Optimal perioperative fluid management is essential for reducing complications in children undergoing thoracoscopic surgery. The study aimed to assess the performance of 2 dynamic preload parameters – pulse pressure variation (PPV) and stroke volume variation (SVV)- either used alone or combined into a multivariable regression model for predicting fluid responsiveness in children undergoing video-assisted thoracoscopic surgery with one-lung ventilation. Children aged 1 to 6 years old undergoing video-assisted pulmonary segmentectomy or lobectomy were enrolled. Volume loading with 5 mL/kg of hydroxyethyl starch was administered over 15 minutes after establishment of artificial pneumothorax. PPV, SVV, cardiac index, cardiac cycle efficiency, and the difference between systolic blood pressure and dicrotic pressure were recorded using the pressure recording analytical method before and after volume loading. Patients with an elevation in cardiac index greater than 10% were defined as responders, and the remaining patients were nonresponders. Of 40 children, 36 were included in the final analysis, containing 13 responders and 23 nonresponders. SVV had an accuracy of 74% (95% confidence interval, 55–93%) for predicting fluid responsiveness, and a best cutoff of 22% showed a sensitivity of 62% and a specificity of 96%. PPV was incapable of discriminating responders from nonresponders. The multivariate regression model did not perform better than SVV alone. We found PPV failed to predict fluid responsiveness, while SVV predicted fluid responsiveness reasonably in the present context. There was no enhancement in predictivity accuracy with multivariable regression models. The accuracy of these approaches was limited, and more discriminative methods need to be found.

17 May 2024 in Heliyon
Verified
Journal Article
Open access
WYWenshuang Yang
Wenshuang Yang
DHDing Han
Ding Han
SPShou-Dong Pan
Shou-Dong Pan
SZShiya Zou
Shiya Zou
SXSiyuan Xie
Siyuan Xie
guimin huangguimin huang
guimin huang
The intercornual distance in the sacral hiatus has yet to be studied precisely in children. This age-stratified, observational study aimed to clarify the changes in sacral hiatus dimensions and to quantify the correlations between the intercornual distance of the sacral hiatus and age, height, weight, and head circumference by using real-time ultrasonography. The patients were stratified into three groups: neonates and infants, toddlers, and schoolchildren. In the operating room, the ultrasonic probe was placed at the sacral cornua to obtain a transverse view of the sacral hiatus, and the intercornual distance was measured three times in millimetres. The study included a total of 156 patients. The mean ± SD (95%CI) of intercornual distance in neonates and infants (36 months). The mean values of neonates and infants were different from those of toddlers and schoolchildren (p < 0.001), but it was similar between toddlers and schoolchildren (p > 0.05, 95 % CI mean difference −1.10 to 0.95). Intercornual distance was correlated with age, height, weight, and head circumference before one year of age (Spearman's R values > 0.7), but there was no correlation thereafter (Spearman's p value > 0.05). In the first year after birth, the intercornual distance increases rapidly with body growth; after one year of age, the sacral hiatus dimension changes significantly. Ultrasound is superior for assessing the gradually ossified cartilage components in older children.

5 February 2021 in Cardiology in the Young
Verified
Journal Article
Closed access
PDF file
BCBoqun Cui
Boqun Cui
COChuan Ou-Yang
Chuan Ou-Yang
SXSiyuan Xie
Siyuan Xie
DLDuomao Lin
Duomao Lin
MJMa Jun
Ma Jun
Objective: To analyse the changes of different ventilation on regional cerebral oxygen saturation and cerebral blood flow in infants during ventricular septal defect repair.Methods: Ninety-two infants younger than 1 year were enrolled in the study. End-expiratory tidal pressure of carbon dioxide was maintained at 40–45 and 35–39 mmHg in relative low and high ventilation groups. Regional cerebral oxygen saturation and flow velocity of the middle cerebral artery were recorded after anaesthesia (T0), cut pericardium (T1), separation from cardiopulmonary bypass (T2), the end of modified ultrafiltration, (T3) and at the end of operation (T4).Results: The relative low ventilation group exhibited a significantly high regional cerebral oxygen saturation at each time point except for T2 (T0:77 ± 4, T1:76 ± 5, T3:76 ± 8, T4:76 ± 8, respectively, p < 0.001). Flow velocity of the middle cerebral artery in the relative low ventilation group was higher compared to the relative high ventilation group at each time point except for T2 (T0:53 ± 14, T1:54 ± 15, T3:53 ± 17, T4:52 ± 16, respectively, p < 0.001). Between the two groups, T2 showed the lowest middle cerebral artery flow velocity (relative low ventilation: 39 ± 15, relative high ventilation: 39 ± 11, p < 0.001).Conclusion: The infants’ regional cerebral oxygen saturation and middle cerebral artery flow velocity performed better in the range of 40–45 mmHg end-expiratory tidal pressure of carbon dioxide during CHD surgery. Modified ultrafiltration increased cerebral oxygen saturation. It was important to regulate ventilation in order to balance cerebral oxygen in infants.