Shou-Dong Pan

Dr. Shou-Dong Pan


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Journal of PeriAnesthesia Nursing
Verified
Journal Article
Open access
YJYingtong Ji
Yingtong Ji
DHDing Han
Ding Han
LHLu Han
Lu Han
SXSiyuan Xie
Siyuan Xie
SPShou-Dong Pan
Shou-Dong Pan
A wireless and wearable axillary thermometer (iThermonitor) has been validated for perioperative core temperature monitoring in adults. The purpose of this study was to evaluate its accuracy in pediatrics having non-cardiac surgery. Prospective observational study. From January 2019 to December 2019, 70 children aged younger than 14 years undergoing surgery in a tertiary hospital were selected. Pairs of esophageal temperatures (TEso), rectal temperatures (TRec), and axillary temperatures monitored by the iThermonitor (TiTh) were collected every 5 min during surgery. Taking TEso as reference, the bias between TEso and TiTh and the proportion of bias within ±0.5°C were calculated. Bland-Altman method was used to analyze the 95% of limits of agreement (LOA) between TiTh and TEso. The same analyses were done for TRec. FINDINGS: A total of 2232 pairs of temperatures were collected. The bias (mean ± SD) between TiTh and TEso was -0.07 °C ± 0.25°C, and 95% LOA was -0.07°C ± 0.50°C. The proportion of bias within ±0.5°C accounted for 96% (95% Confidence Interval [CI], 92-98%). Higher bias and 95% LOA, and lower proportion of bias within ± 0.5°C were found between TRec and TEso than those between TiTh and TEso. During pediatric non-cardiac surgery, axillary temperature derived from iThermonitor is in good agreement with esophageal temperature and can be used as an alternative to core temperature.


9 December 2022 in Medicine
Verified
Journal Article
Open access
SXSiyuan Xie
Siyuan Xie
DHDing Han
Ding Han
GCGang Chen
Gang Chen
SPShou-Dong Pan
Shou-Dong Pan
Optimal perioperative fluid management is essential for reducing complications in children undergoing thoracoscopic surgery. The study aimed to assess the performance of 2 dynamic preload parameters – pulse pressure variation (PPV) and stroke volume variation (SVV)- either used alone or combined into a multivariable regression model for predicting fluid responsiveness in children undergoing video-assisted thoracoscopic surgery with one-lung ventilation. Children aged 1 to 6 years old undergoing video-assisted pulmonary segmentectomy or lobectomy were enrolled. Volume loading with 5 mL/kg of hydroxyethyl starch was administered over 15 minutes after establishment of artificial pneumothorax. PPV, SVV, cardiac index, cardiac cycle efficiency, and the difference between systolic blood pressure and dicrotic pressure were recorded using the pressure recording analytical method before and after volume loading. Patients with an elevation in cardiac index greater than 10% were defined as responders, and the remaining patients were nonresponders. Of 40 children, 36 were included in the final analysis, containing 13 responders and 23 nonresponders. SVV had an accuracy of 74% (95% confidence interval, 55–93%) for predicting fluid responsiveness, and a best cutoff of 22% showed a sensitivity of 62% and a specificity of 96%. PPV was incapable of discriminating responders from nonresponders. The multivariate regression model did not perform better than SVV alone. We found PPV failed to predict fluid responsiveness, while SVV predicted fluid responsiveness reasonably in the present context. There was no enhancement in predictivity accuracy with multivariable regression models. The accuracy of these approaches was limited, and more discriminative methods need to be found.