In this article, we address the problem of singular value decomposition of polynomial matrices and eigenvalue decomposition of para-Hermitian matrices. Discrete Fourier transform enables us to propose a new algorithm based on uniform sampling of polynomial matrices in frequency domain. This formulation of polynomial matrix decomposition allows for controlling spectral properties of the decomposition. We set up a nonlinear quadratic minimization for phase alignment of decomposition at each frequency sample, which leads to a compact order approximation of decomposed matrices. Compact order approximation of decomposed matrices makes it suitable in filterbank and multiple-input multiple-output (MIMO) precoding applications or any application dealing with realization of polynomial matrices as transfer function of MIMO systems. Numerical examples demonstrate the versatility of the proposed algorithm provided by relaxation of paraunitary constraint, and its configurability to select different properties.
Impedance-based structural health monitoring (ISHM) using piezoelectric materials has been extensively developed to provide a structure health indicator. In practice, due to the environmental disturbances, the received signal in different surrounding conditions may be different from intact structure received signal. In the past, any difference was assumed being caused by damage even changes such as temperature effects on the received signal. In ISHM, the received signal is different from the intact structure received signal; however, there is not necessarily damage in the system. So, the validity of ISHM depends on the identification of environmental disturbances in order to extract the real results from disturbed results. In this article, a new method using sensor array and statistical metric analysis has been proposed to identify signal changes derived from damage and/or environmental change. Using this method, it is expected that the environmental variations affect similarly on output signals of different row sensors, whereas changes caused by damage will not be similar for all row and column sensors. This expectation is a general fact because there would be no sensible difference in the environmental variations from one side to other sides of the structure. To identify environmental disturbance from damage detection, an analysis is developed using statistical metrics. Experimental results show that this method is reliable to identify damage.
30 August 2023 in Stochastic Environmental Research and Risk Assessment