Yong-Beom Shin

Dr. Yong-Beom Shin

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2009 in Sensors
Verified
Journal Article
Open access
PDF file
HKHyungmin Kim
Hyungmin Kim
SJSeung Min Jin
Seung Min Jin
SLSeok Kee Lee
Seok Kee Lee
MKMin-Gon Kim
Min-Gon Kim
YSYong-Beom Shin
Yong-Beom Shin
To amplify the difference in localized surface plasmon resonance (LSPR) spectra of gold nano-islands due to intermolecular binding events, gold nanoparticles were used. LSPR-based optical biosensors consisting of gold nano-islands were readily made on glass substrates using evaporation and heat treatment. Streptavidin (STA) and biotinylated bovine serum albumin (Bio-BSA) were chosen as the model receptor and the model analyte, respectively, to demonstrate the effectiveness of this detection method. Using this model system, we were able to enhance the sensitivity in monitoring the binding of Bio-BSA to gold nano-island surfaces functionalized with STA through the addition of gold nanoparticle-STA conjugates. In addition, SU-8 well chips with gold nano-island surfaces were fabricated through a conventional UV patterning method and were then utilized for image detection using the attenuated total reflection mode. These results suggest that the gold nano-island well chip may have the potential to be used for multiple and simultaneous detection of various bio-substances.

1 January 2018 in Polymers
Verified
Journal Article
Open access
PDF file
HHHiep Nguyen Hoang
Hiep Nguyen Hoang
JPJeho Park
Jeho Park
SPSeon Joo Park
Seon Joo Park
Chang-Soo LeeChang-Soo Lee
Chang-Soo Lee
SHSeungwoo Hwang
Seungwoo Hwang
Moonil KimMoonil Kim
Moonil Kim
Validation of long-term DNA stability and integrity are essential for the use of DNA in data storage applications. Because of this, we evaluated the plasmid-based DNA data storage in a manner that preserves DNA stability and integrity. A document consisting of 2046 words was encoded with DNA sequences using Perl script, and the encoded DNA sequences were synthesized for information storage. The DNA comprised a total of 22 chemically synthesized DNA fragments with 400 nucleotides each, which were incorporated into a plasmid vector. A long-term DNA stability study demonstrated that 3-year stored plasmid containing text information showed DNA stability at controlled conditions of −20 °C. The plasmid DNA under accelerated aging conditions (AAC) up to 65 °C for 20 days, which corresponds to approximately 20 years of storage at −20 °C, also exhibited no significant differences in DNA stability compared to newly produced plasmid. Also, the 3-year old plasmid stored at −20 °C and the AAC-tested plasmid stored up to 65 °C for 20 days had functional integrity and nucleotide integrity comparable to control sample, thereby allowing for retrieval of the original error-free text data. Finally, the nucleotides were sequenced, and then decoded to retrieve the original data, thereby allowing us to read the text with 100% accuracy, and amplify the DNA with a simple and quick bacterial transformation. To the best of our knowledge, this is the first report on examining the long-term stability and integrity of plasmid-based DNA data storage. Taken together, our results indicate that plasmid DNA data storage can be useful for long-term archival storage to recover the source text in a reproducible and accountable manner.

12 March 2010 in Sensors
Verified
Journal Article
Open access
PDF file
TLTae-Han Lee
Tae-Han Lee
SLSeung-Woo Lee
Seung-Woo Lee
JJJi-Ae Jung
Ji-Ae Jung
JAJunhyoung Ahn
Junhyoung Ahn
MKMin-Gon Kim
Min-Gon Kim
YSYong-Beom Shin
Yong-Beom Shin
An enzymatic reaction was employed as a means to enhance the sensitivity of an immunosensor based on localized surface plasmon resonance (LSPR). The reaction occurs after intermolecular binding between an antigen and an antibody on gold nano-island (NI) surfaces. For LSPR sensing, the gold NI surface was fabricated on glass substrates using vacuum evaporation and heat treatment. The interferon-g (IFN-g) capture antibody was immobilized on the gold NIs, followed by binding of IFN-g to the antibody. Subsequently, a biotinylated antibody and a horseradish peroxidase (HRP) conjugated with avidin were simultaneously introduced. A solution of 4-chloro-1-naphthol (4-CN) was then used for precipitation; precipitation was the result of the enzymatic reaction catalyzed the HRP on gold NIs. The LSPR spectra were obtained after each binding process. Using this method, the enzyme-catalyzed precipitation reaction on the gold NI surface was found to effectively amplify the change in the signal of the LSPR immunosensor after intermolecular binding.

1 July 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
NJNa Rae Jo
Na Rae Jo
KLKi Joong Lee
Ki Joong Lee
YSYong-Beom Shin
Yong-Beom Shin

1 April 2007 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
YSYong-Beom Shin
Yong-Beom Shin
JLJeong-Min Lee
Jeong-Min Lee
MPMi-Ra Park
Mi-Ra Park
MKMin-Gon Kim
Min-Gon Kim
BCBong Hyun Chung
Bong Hyun Chung
SMSunglyul Maeng
Sunglyul Maeng

16 February 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
YKYonghee Kim
Yonghee Kim
AAAbdurhaman Teyib Abafogi
Abdurhaman Teyib Abafogi
BTBUU MINH TRAN
BUU MINH TRAN
JKJaewon Kim
Jaewon Kim
JLJinyeop Lee
Jinyeop Lee
Sungsu ParkSungsu Park
Sungsu Park
Influenza A viruses are often present in environmental and clinical samples at concentrations below the limit of detection (LOD) of molecular diagnostics. Here we report an integrated microfluidic preconcentration and nucleic amplification system (μFPNAS) which enables both preconcentration of influenza A virus H1N1 (H1N1) and amplification of its viral RNA, thereby lowering LOD for H1N1. H1N1 virus particles were first magnetically preconcentrated using magnetic nanoparticles conjugated with an antibody specific for the virus. Their isolated RNA was amplified to cDNA through thermocycling in a trapezoidal chamber of the μFPNAS. A detection limit as low as 100 TCID50 (50% tissue culture infective dose) in saliva can be obtained within 2 hours. These results suggest that the LOD of molecular diagnostics for virus can be lowered by systematically combining immunomagnetic separation and reverse transcriptase-polymerase chain reaction (RT-PCR) in one microfluidic device.