Yuki Narita

Dr. Yuki Narita

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
YNYuki Narita
Yuki Narita
TKTakahiro Kato
Takahiro Kato
KTKimihiro Takemasa
Kimihiro Takemasa
HSHiroki Sato
Hiroki Sato
TITomohiro Ikeda
Tomohiro Ikeda
MMMasao Murakami
Masao Murakami
Purpose: To investigate the dosimetric impact of changes in the large bowel content during proton therapy (PT) with simultaneous integrated boost (SIB) for locally advanced pancreatic cancer (LAPC).Materials and methods: Fifteen patients with LAPC were included in this study. The SIB method was performed using five fields according to our standard protocol. A total dose of 67.5 Gy(relative biological effectiveness [RBE]) was prescribed in 25 fractions using the SIB method. A dose of 45 Gy(RBE) was prescribed for the entire planning target volume (PTV) by using four main fields. The remaining 22.5 Gy(RBE) was prescribed to the PTV excluding for the gastrointestinal tract using one subfield. Five simulated doses were obtained by the forward dose calculations with the Hounsfield units (HU) override to the large bowel to 50, 0, −100, −500, and −1000, respectively. The dose‐volume indices in each plan were compared using the 50 HU plan as a reference.Results: At D98 of the clinical target volume (CTV) and spinal cord‐D2cc, when the density of the large bowel was close to that of gas, there were significant differences compared to the reference plan (p < 0.05). By contrast, no significant difference was observed in stomach‐D2cc duodenum‐D2cc, small bowel‐D2cc, kidneys‐V18, and liver‐Dmean under any of the conditions. There were no cases in which the dose constraint of organs at risk, specified by our institution, was exceeded.Conclusion: Density change in the large bowel was revealed to significantly affect the doses of the CTV and spinal cord during PT with SIB for LAPC. For beam arrangement, it is important to select a gantry angle that prevents the large bowel from passing as much as possible. If this is unavoidable, it is important to carefully observe the gas image on the beam path during daily image guidance and to provide adaptive re‐planning as needed.

2 October 2024 in Physica Medica
Verified
Journal Article
Closed access
SKShinya Komori
Shinya Komori
KHKatsumi Hirose
Katsumi Hirose
MSMariko Sato
Mariko Sato
YYYuhei Yamazaki
Yuhei Yamazaki
ATAkihiko Takeuchi
Akihiko Takeuchi
YTYoshihiro Takai
Yoshihiro Takai

25 March 2022 in Medical Dosimetry
Verified
Journal Article
Closed access
TKTakahiro Kato
Takahiro Kato
TOTakashi Ono
Takashi Ono
YNYuki Narita
Yuki Narita
SKShinya Komori
Shinya Komori
MMMasao Murakami
Masao Murakami

31 July 2022 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
RKRyohei Kato
Ryohei Kato
KHKatsumi Hirose
Katsumi Hirose
TKTakahiro Kato
Takahiro Kato
TMTomoaki Motoyanagi
Tomoaki Motoyanagi
KAKazuhiro Arai
Kazuhiro Arai
YTYoshihiro Takai
Yoshihiro Takai

1 February 2024 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
TKTakahiro Kato
Takahiro Kato
KTKimihiro Takemasa
Kimihiro Takemasa
TITomohiro Ikeda
Tomohiro Ikeda
HSHisanori Sakagami
Hisanori Sakagami
RKRyohei Kato
Ryohei Kato
MMMasao Murakami
Masao Murakami
Purpose: To analyze the respiratory‐induced motion trajectories of each liver segment for hepatocellular carcinoma (HCC) to derive a more accurate internal margin and optimize treatment protocol selection.Materials and Methods: Ten‐phase‐gated four‐dimensional computed tomography (4DCT) scans of 14 patients with HCC were analyzed. For each patient, eight representative regions of interest (ROI) were delineated on each liver segment in all 10 phases. The coordinates of the center of gravity of each ROI were obtained for each phase, and then the respiratory motion in the left–right (LR), anteroposterior (AP), and craniocaudal (CC) directions was analyzed. Two sets of motion in each direction were also compared in terms of only two extreme phases and all 10 phases.Results: Motion of less than 5 mm was detected in 12 (86%) and 10 patients (71%) in the LR and AP directions, respectively, while none in the CC direction. Motion was largest in the CC direction with a maximal value of 19.5 mm, with significant differences between liver segment 7 (S7) and other segments: S1 (p < 0.036), S2 (p < 0.041), S3 (p < 0.016), S4 (p < 0.041), and S5 (p < 0.027). Of the 112 segments, hysteresis >1 mm was observed in 4 (4%), 2 (2%), and 15 (13%) in the LR, AP, and CC directions, respectively, with a maximal value of 5.0 mm in the CC direction.Conclusion: A significant amount of respiratory motion was detected in the CC direction, especially in S7, and S8. Despite the small effect of hysteresis, it can be observed specifically in the right lobe. Therefore, caution is required when using 4DCT to determine IM using only end‐inspiration and end‐expiration. Understanding the respiratory motion in individual liver segments can be helpful when selecting an appropriate treatment protocol.

18 September 2024 in Medical Physics
Verified
Journal Article
Closed access
SKShinya Komori
Shinya Komori
ATAkihiko Takeuchi
Akihiko Takeuchi
RKRyohei Kato
Ryohei Kato
YYYuhei Yamazaki
Yuhei Yamazaki
TMTomoaki Motoyanagi
Tomoaki Motoyanagi
YTYoshihiro Takai
Yoshihiro Takai