ALESSANDRO COPPOLECCHIA

Dr. ALESSANDRO COPPOLECCHIA

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Journal of Cosmology and Astroparticle Physics
Verified
Journal Article
Closed access
PDF file
APA. Paiella
A. Paiella
ACALESSANDRO COPPOLECCHIA
ALESSANDRO COPPOLECCHIA
LLL. Lamagna
L. Lamagna
PAP.A.R. Ade
P.A.R. Ade
Elia Stefano BattistelliElia Stefano Battistelli
Elia Stefano Battistelli
CTC. Tucker
C. Tucker
We designed, fabricated, and characterized four arrays of horn-coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environment. The corrected focal plane is filled with diffraction limited horn-coupled KID arrays, with 19, 37, 23, 41 active pixels respectively at 150, 250, 350, and 460 GHz. Here we report on the full electrical and optical characterization performed on these detector arrays before the flight. In a dark laboratory cryostat, we measured the resonator electrical parameters, such as the quality factors and the electrical responsivities, at a base temperature of 300 mK. The measured average resonator Qs are 1.7× 104, 7.0× 103, 1.0× 104, and 1.0× 104 for the 150, 250, 350, and 460 GHz arrays, respectively. The average electrical phase responsivities on resonance are 1.4 rad/pW, 1.5 rad/pW, 2.1 rad/pW, and 2.1 rad/pW; the electrical noise equivalent powers are 45 aW/√Hz, 160 aW/√Hz, 80 aW/√Hz, and 140 aW/√Hz, at 12 Hz. In the OLIMPO cryostat, we measured the optical properties, such as the noise equivalent temperatures (NET) and the spectral responses. The measured NETRJs are 200 μ K.√s, 240 μK √s, 240 μK √s, and 340 μK √s, at 12 Hz; under 78, 88, 92, and 90 mK Rayleigh-Jeans blackbody load changes respectively for the 150, 250, 350, and 460 GHz arrays. The spectral responses were characterized with the OLIMPO differential Fourier transform spectrometer (DFTS) up to THz frequencies, with a resolution of 1.8 GHz.

23 January 2019 in Universe
Verified
Journal Article
Open access
PDF file
AMAniello Mennella
Aniello Mennella
PAPeter Ade
Peter Ade
GAGiorgio Amico
Giorgio Amico
DADidier Auguste
Didier Auguste
JAJonathan Aumont
Jonathan Aumont
AZAntonio Zullo
Antonio Zullo
In this paper, we describe QUBIC, an experiment that will observe the polarized microwave sky with a novel approach, which combines the sensitivity of state-of-the-art bolometric detectors with the systematic effects control typical of interferometers. QUBIC’s unique features are the so-called “self-calibration”, a technique that allows us to clean the measured data from instrumental effects, and its spectral imaging power, i.e., the ability to separate the signal into various sub-bands within each frequency band. QUBIC will observe the sky in two main frequency bands: 150 GHz and 220 GHz. A technological demonstrator is currently under testing and will be deployed in Argentina during 2019, while the final instrument is expected to be installed during 2020.

9 December 2019 in Journal of Low Temperature Physics
Verified
Journal Article
Closed access
PDF file
ACALESSANDRO COPPOLECCHIA
ALESSANDRO COPPOLECCHIA
APA. Paiella
A. Paiella
LLL. Lamagna
L. Lamagna
GPG. Presta
G. Presta
EBE. S. Battistelli
E. S. Battistelli
FPF. Piacentini
F. Piacentini

22 July 2020 in Cryogenics
Verified
Journal Article
Closed access
ACALESSANDRO COPPOLECCHIA
ALESSANDRO COPPOLECCHIA
LLL. Lamagna
L. Lamagna
SMS. Masi
S. Masi
PAP.A.R. Ade
P.A.R. Ade
GAG. Amico
G. Amico
MZM. Zannoni
M. Zannoni

21 January 2023 in Journal of Low Temperature Physics
Verified
Journal Article
Closed access
PDF file
ACALESSANDRO COPPOLECCHIA
ALESSANDRO COPPOLECCHIA
EBE. S. Battistelli
E. S. Battistelli
SMS. Masi
S. Masi
PMP. Marongiu
P. Marongiu
EBE. Barbavara
E. Barbavara
FRF. Radiconi
F. Radiconi

9 July 2018
Verified
Conference Paper
Open access
PDF file
AMAndrew May
Andrew May
CCClaude Chapron
Claude Chapron
GCGabriele Coppi
Gabriele Coppi
GDGiuseppe D'Alessandro
Giuseppe D'Alessandro
PBPaolo de Bernardis
Paolo de Bernardis
MTMatthieu Tristram
Matthieu Tristram
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.