G. Presta

G. Presta

Auto-generated profile, based on publicly available information

G. Presta

Sapienza Università di Roma

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Journal of Cosmology and Astroparticle Physics
Verified
Journal Article
Closed access
PDF file
SMS. Masi
S. Masi
PBP. de Bernardis
P. de Bernardis
APA. Paiella
A. Paiella
FPF. Piacentini
F. Piacentini
LLL. Lamagna
L. Lamagna
DYD. Yvon
D. Yvon

1 January 2019 in Journal of Cosmology and Astroparticle Physics
Verified
Journal Article
Closed access
PDF file
APA. Paiella
A. Paiella
ACALESSANDRO COPPOLECCHIA
ALESSANDRO COPPOLECCHIA
LLL. Lamagna
L. Lamagna
PAP.A.R. Ade
P.A.R. Ade
Elia Stefano BattistelliElia Stefano Battistelli
Elia Stefano Battistelli
CTC. Tucker
C. Tucker
We designed, fabricated, and characterized four arrays of horn-coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environment. The corrected focal plane is filled with diffraction limited horn-coupled KID arrays, with 19, 37, 23, 41 active pixels respectively at 150, 250, 350, and 460 GHz. Here we report on the full electrical and optical characterization performed on these detector arrays before the flight. In a dark laboratory cryostat, we measured the resonator electrical parameters, such as the quality factors and the electrical responsivities, at a base temperature of 300 mK. The measured average resonator Qs are 1.7× 104, 7.0× 103, 1.0× 104, and 1.0× 104 for the 150, 250, 350, and 460 GHz arrays, respectively. The average electrical phase responsivities on resonance are 1.4 rad/pW, 1.5 rad/pW, 2.1 rad/pW, and 2.1 rad/pW; the electrical noise equivalent powers are 45 aW/√Hz, 160 aW/√Hz, 80 aW/√Hz, and 140 aW/√Hz, at 12 Hz. In the OLIMPO cryostat, we measured the optical properties, such as the noise equivalent temperatures (NET) and the spectral responses. The measured NETRJs are 200 μ K.√s, 240 μK √s, 240 μK √s, and 340 μK √s, at 12 Hz; under 78, 88, 92, and 90 mK Rayleigh-Jeans blackbody load changes respectively for the 150, 250, 350, and 460 GHz arrays. The spectral responses were characterized with the OLIMPO differential Fourier transform spectrometer (DFTS) up to THz frequencies, with a resolution of 1.8 GHz.

13 January 2016 in Journal of Low Temperature Physics
Verified
Journal Article
Closed access
PDF file
APA. Paiella
A. Paiella
ACA. Coppolecchia
A. Coppolecchia
MCM. G. Castellano
M. G. Castellano
ICI. Colantoni
I. Colantoni
ACA. Cruciani
A. Cruciani
GPG. Presta
G. Presta

10 February 2020 in Journal of Low Temperature Physics
Verified
Journal Article
Closed access
PDF file
APA. Paiella
A. Paiella
PAP. A. R. Ade
P. A. R. Ade
EBE. S. Battistelli
E. S. Battistelli
MCM. G. Castellano
M. G. Castellano
ICI. Colantoni
I. Colantoni
DYD. Yvon
D. Yvon

1 January 2019 in Astronomische Nachrichten
Verified
Journal Article
Open access
PDF file
FCF. Columbro
F. Columbro
EBE. S. Battistelli
E. S. Battistelli
ACA. Coppolecchia
A. Coppolecchia
GDG. D'Alessandro
G. D'Alessandro
PBP. de Bernardis
P. de Bernardis
GPG. Presta
G. Presta
In this paper we investigate the impact of using a polarization modulator in The Short Wavelength Instrument for the Polarization Explorer (SWIPE) of the large scale polarization explorer (LSPE). The experiment is optimized to measure the linear polarization of the cosmic microwave background at large angular scales during a circumpolar long‐duration stratospheric balloon mission, and uses multimode bolometers cooled to .3 K. The 330 detectors cover three bands at 140, 220, and 240 GHz. Polarimetry is achieved by means of a large rotating half‐wave plate (HWP) and a single wire‐grid polarizer in front of the arrays. The polarization modulator is the first polarization‐active component of the optical chain, reducing significantly the effect of instrumental polarization. A trade‐off study comparing stepped versus spinning HWPs drives the choice towards the second. Modulating the cosmic microwave background polarization signal at four times the spin frequency moves it away from 1/f noise from the detectors and the residual atmosphere. The HWP is cooled to 1.6 K to reduce the background on the detectors. Furthermore, its polarized emission combined with the emission of the polarizer produces spurious signals modulated at 2f and 4f. The 4f component is synchronous with the signal of interest and has to characterized to be removed from cosmological data.

17 April 2020 in Journal of Low Temperature Physics
Verified
Journal Article
Closed access
PDF file
LLL. Lamagna
L. Lamagna
GAG. Addamo
G. Addamo
PAP. A. R. Ade
P. A. R. Ade
CBC. Baccigalupi
C. Baccigalupi
ABA. M. Baldini
A. M. Baldini
MZM. Zannoni
M. Zannoni