By integrating simulated annealing and the interactive best-compromise approach, this study proposed a method for determining economic dispatch in power systems while accounting for carbon emissions. To satisfy load demands and operational constraints, traditional economic dispatch is determined through the minimization of total power generation costs based on the power output of the generating units in a system. In the proposed method, carbon emissions are taken into consideration. A CO2 equivalent model was created that accounted for the various fuel types (e.g., coal, oil, and natural gas) used in power generation. The correlation between power generation costs and carbon emissions was determined according to CO2 emissions tradeoff and incremental cost-CO2 reduction curves. The proposed method was applied to the Taiwan Power Company system. The results indicated that the method was effective at determining the influence of CO2 emissions on power generation costs during off-peak, semi-peak, and peak hours, as well as daily load demands. The system enables the simultaneous consideration of economic and environmental benefits.
By consulting various worldwide definitions of microgrids and distributed energy, this study presents a microgrid-structured multi-agent system and uses Matlab/Simulink to construct a circuit with microgrid features, which enables the changes in each electrical source and load in the microgrid to be monitored and controlled. This multi-agent system adheres to the Java Agent Development Framework (JADE) platform specifications of the Foundation for Intelligent Physical Agents (FIPA), facilitating communication, information transfers, and the receipt of real-time information regarding the microgrid and each component in the microgrid. Furthermore, the real-time state in the microgrid can be correspondingly controlled, achieving the most efficient real-time monitoring and control for electrical sources and load management in the microgrid.
9 February 2021 in IEEE Transactions on Industry Applications
The aim of this article is to explore various operating situations of a microgrid based on master-slave control and the self-healing of the microgrid after fault detection. It also finds a scheduling strategy for the energy-storage equipment through an artificial bee colony algorithm to meet the needs of the microgrid. Many operating modes will face multiple instances of connection and disconnection operations. The disturbance generated by distributed energy resources can be effectively reduced through the regulation of the voltage, frequency, and phase angle. Moreover, when the microgrid is disconnected, its power flow will reduce the disturbance. In addition, a fault point is detected when there is a fault. The recovery and isolation actions are automatically carried out, which can reduce the area affected by the fault and enable the nonfault area to quickly restore the power supply. Therefore, the self-healing function of the power grid is achieved. In this article, the bee colony algorithm is applied to the scheduling strategy for the operation of the energy-storage equipment. Multiple demands need to be satisfied by the energy-storage equipment. Multiple assessment indicators are set up as the basis for the algorithm to assess the merits and demerits of the scheduling strategy. The experimental results show that the control of the energy-storage equipment through the bee colony algorithm can satisfy the demands of the various characteristics of the microgrid. It can also reduce the peak load during critical periods and maintain the reliability of the system.
When large amounts of wind power and solar photovoltaic (PV) power are integrated into an independent power grid, the intermittent renewable energy destabilizes power output. Therefore, this study explored the unit commitment (UC) optimization problem; the ramp rate was applied to solve problems with 30 and 10 min of power shortage. The data of actual unit parameters were provided by the Taiwan Power Company. The advanced priority list method was used together with a combination of a generalized Lagrangian relaxation algorithm and a random feasible directions algorithm to solve a large-scale nonlinear mixed-integer programming UC problem to avoid local and infeasible solutions. The results showed that the proposed algorithm was superior to improved particle swarm optimization (IPSO) and simulated annealing (SA) in terms of the minimization of computation time and power generation cost. The proposed method and UC results can be effective information for unit dispatch by power companies to reduce the investment costs of power grids and the possibility of renewable energy being disconnected from the power system. Thus, the proposed method can increase the flexibility of unit dispatch and the proportion of renewable energy in power generation.
6 January 2014 in IEEE Transactions on Industry Applications
In the power supply system of an electrified railway, a pantograph in contact with the overhead train line is used to send electricity to the main transformer of the electric train, thus providing power. However, due to many external influences, such as the shaking caused by high-speed driving, the bouncing and contact friction between the pantograph and the train line, weather, terrain, and uneven surface wear, the overhead train line may lose contact with the pantograph, causing arcing phenomena to occur. This paper proposes the use of the physical properties of magnetic components to improve the contact between the pantograph and the overhead train line (i.e., reducing the contact loss rate), constructs a model to simulate the contact loss rate of pantographs and train lines, and analyzes the circumstances and frequency of arcing. The experimental results demonstrate that contact loss rate, arcing, and the contact surface wear of pantographs and train lines can be effectively reduced using magnetic components, reducing the investment costs of electrified railways and improving the quality of power transmission for electric trains.
Quasi-resonant flyback (QRF) converters have been widely applied as the main circuit topology in power converters because of their low cost and high efficiency. Conventional QRF converters tend to generate higher average conducted electromagnetic interference (EMI) in the low-frequency domain due to the switching noise generated by power switches, resulting in the fact they can exceed the EMI standards of the European Standard 55022 Class-B emission requirements. The presented paper develops a novel frequency swapping control method that spreads spectral energy to reduce the amplitude of sub-harmonics, thereby lowering average conducted EMI in the low-frequency domain. The proposed method is implemented in a control chip, which requires no extra circuit components and adds zero cost. The proposed control method is verified using a 24 W QRF converter. Experimental results reveals that conducted EMI has been reduced by approximately 13.24 dBμV at 498 kHz compared with a control method without the novel frequency swapping technique. Thus, the proposed method can effectively improve the flyback system to easily meet the CISPR 22/EN55022 standards.