Fanny Grosselin

Ms. Fanny Grosselin

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
MCM. Chavez
M. Chavez
FGFanny Grosselin
Fanny Grosselin
ABAurore Bussalb
Aurore Bussalb
FFF. De Vico Fallani
F. De Vico Fallani
XNX. Navarro-Sune
X. Navarro-Sune
Objective: the recent emergence and success of electroencephalography (EEG) in low-cost portable devices, has opened the door to a new generation of applications processing a small number of EEG channels for health monitoring and brain-computer interfacing. These recordings are, however, contaminated by many sources of noise degrading the signals of interest, thus compromising the interpretation of the underlying brain state. In this paper, we propose a new data-driven algorithm to effectively remove ocular and muscular artifacts from single-channel EEG: the surrogate-based artifact removal (SuBAR). Methods: by means of the time-frequency analysis of surrogate data, our approach is able to identify and filter automatically ocular and muscular artifacts embedded in single-channel EEG. Results: in a comparative study using artificially contaminated EEG signals, the efficacy of the algorithm in terms of noise removal and signal distortion was superior to other traditionally-employed single-channel EEG denoizing techniques: wavelet thresholding and the canonical correlation analysis combined with an advanced version of the empirical mode decomposition. Even in the presence of mild and severe artifacts, our artifact removal method provides a relative error 4 to 5 times lower than traditional techniques. Significance: in view of these results, the SuBAR method is a promising solution for mobile environments, such as ambulatory healthcare systems, sleep stage scoring, or anesthesia monitoring, where very few EEG channels or even a single channel is available.

24 August 2017 in Brain
Verified
Journal Article
Open access
PDF file
TATristan Altwegg-Boussac
Tristan Altwegg-Boussac
ASAdrien E Schramm
Adrien E Schramm
JBJimena Ballestero
Jimena Ballestero
FGFanny Grosselin
Fanny Grosselin
MCMario Chavez
Mario Chavez
SCStéphane Charpier
Stéphane Charpier
A continuous isoelectric electroencephalogram reflects an interruption of endogenously-generated activity in cortical networks and systematically results in a complete dissolution of conscious processes. This electro-cerebral inactivity occurs during various brain disorders, including hypothermia, drug intoxication, long-lasting anoxia and brain trauma. It can also be induced in a therapeutic context, following the administration of high doses of barbiturate-derived compounds, to interrupt a hyper-refractory status epilepticus. Although altered sensory responses can be occasionally observed on an isoelectric electroencephalogram, the electrical membrane properties and synaptic responses of individual neurons during this cerebral state remain largely unknown. The aim of the present study was to characterize the intracellular correlates of a barbiturate-induced isoelectric electroencephalogram and to analyse the sensory-evoked synaptic responses that can emerge from a brain deprived of spontaneous electrical activity. We first examined the sensory responsiveness from patients suffering from intractable status epilepticus and treated by administration of thiopental. Multimodal sensory responses could be evoked on the flat electroencephalogram, including visually-evoked potentials that were significantly amplified and delayed, with a high trial-to-trial reproducibility compared to awake healthy subjects. Using an analogous pharmacological procedure to induce prolonged electro-cerebral inactivity in the rat, we could describe its cortical and subcortical intracellular counterparts. Neocortical, hippocampal and thalamo-cortical neurons were all silent during the isoelectric state and displayed a flat membrane potential significantly hyperpolarized compared with spontaneously active control states. Nonetheless, all recorded neurons could fire action potentials in response to intracellularly injected depolarizing current pulses and their specific intrinsic electrophysiological features were preserved. Manipulations of the membrane potential and intracellular injection of chloride in neocortical neurons failed to reveal an augmented synaptic inhibition during the isoelectric condition. Consistent with the sensory responses recorded from comatose patients, large and highly reproducible somatosensory-evoked potentials could be generated on the inactive electrocorticogram in rats. Intracellular recordings revealed that the underlying neocortical pyramidal cells responded to sensory stimuli by complex synaptic potentials able to trigger action potentials. As in patients, sensory responses in the isoelectric state were delayed compared to control responses and exhibited an elevated reliability during repeated stimuli. Our findings demonstrate that during prolonged isoelectric brain state neurons and synaptic networks are dormant rather than excessively inhibited, conserving their intrinsic properties and their ability to integrate and propagate environmental stimuli.

31 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
FGFanny Grosselin
Fanny Grosselin
XNXavier Navarro-Sune
Xavier Navarro-Sune
AVAlessia Vozzi
Alessia Vozzi
KPKaterina Pandremmenou
Katerina Pandremmenou
FFFabrizio De Vico Fallani
Fabrizio De Vico Fallani
MCMario Chavez
Mario Chavez
The recent embedding of electroencephalographic (EEG) electrodes in wearable devices raises the problem of the quality of the data recorded in such uncontrolled environments. These recordings are often obtained with dry single-channel EEG devices, and may be contaminated by many sources of noise which can compromise the detection and characterization of the brain state studied. In this paper, we propose a classification-based approach to effectively quantify artefact contamination in EEG segments, and discriminate muscular artefacts. The performance of our method were assessed on different databases containing either artificially contaminated or real artefacts recorded with different type of sensors, including wet and dry EEG electrodes. Furthermore, the quality of unlabelled databases was evaluated. For all the studied databases, the proposed method is able to rapidly assess the quality of the EEG signals with an accuracy higher than 90%. The obtained performance suggests that our approach provide an efficient, fast and automated quality assessment of EEG signals from low-cost wearable devices typically composed of a dry single EEG channel.

16 September 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FGFanny Grosselin
Fanny Grosselin
ABAudrey Breton
Audrey Breton
LYLydia Yahia-Cherif
Lydia Yahia-Cherif
XWXi Wang
Xi Wang
GSGiuseppe Spinelli
Giuseppe Spinelli
NGNathalie George
Nathalie George
The neuromodulation induced by neurofeedback training (NFT) remains a matter of debate. Investigating the modulation of brain activity specifically associated with NF requires controlling for multiple factors, such as reward, performance, congruency between task and targeted brain activity. This can be achieved using sham feedback (FB) control condition, equating all aspects of the experiment but the link between brain activity and FB. We aimed at investigating the modulation of individual alpha EEG activity induced by NFT in a double-blind, randomized, sham-controlled study. Forty-eight healthy participants were assigned to eitherNF(n = 25) orcontrol(n = 23) group and performed alpha upregulation training (over 12 weeks) with a wearable EEG device. Participants of theNF groupreceived FB based on their individual alpha activity. Thecontrol groupreceived the auditory FB of participants of theNF group. An increase of alpha activity across training sessions was observed in theNF grouponly (p < 0.001). This neuromodulation was selective in that there was no evidence for similar effects in the theta (4–8 Hz) and low beta (13–18 Hz) bands. While alpha upregulation was found in theNF grouponly, psychological outcome variables showed overall increased feeling of control, decreased anxiety level and increased relaxation feeling, without any significant difference between theNFand thecontrolgroups. This is interpreted in terms of learning context and placebo effects. Our results pave the way to self-learnt, NF-based neuromodulation with light-weighted, wearable EEG systems.

1 October 2018 in Journal of Neuroscience Methods
Verified
Journal Article
Closed access
FGFanny Grosselin
Fanny Grosselin
XNX. Navarro-Sune
X. Navarro-Sune
MRM. Raux
M. Raux
TST. Similowski
T. Similowski
MCM. Chavez
M. Chavez

1 January 2018
Verified
Conference Paper
Open access
FGFanny Grosselin
Fanny Grosselin
YAY. Attal
Y. Attal
MCM. Chavez
M. Chavez