Spontaneous ventilation in mammals is driven by automatic brainstem networks that generate the respiratory rhythm and increase ventilation in the presence of increased carbon dioxide production. Hypocapnia decreases the drive to breathe and induces apnea. In humans, this occurs during sleep but not during wakefulness. We hypothesized that hypocapnic breathing would be associated with respiratory-related cortical activity similar to that observed during volitional breathing, inspiratory constraints, or in patients with defective automatic breathing (preinspiratory potentials). Nineteen healthy subjects were studied under passive (mechanical ventilation,n= 10) or active (voluntary hyperventilation,n= 9) profound hypocapnia. Ventilatory and electroencephalographic recordings were performed during voluntary sniff maneuvers, normocapnic breathing, hypocapnia, and after return to normocapnia. EEG recordings were analyzed with respect to the ventilatory flow signal to detect preinspiratory potentials in frontocentral electrodes and to construct time-frequency maps. After passive hyperventilation, hypocapnia was associated with apnea in 3 cases and ventilation persisted in 7 cases (3 and 6 after active hyperventilation, respectively). No respiratory-related EEG activity was observed in subjects with hypocapnia-related apneas. In contrast, preinspiratory potentials were present at vertex recording sites in 12 of the remaining 13 subjects (p< 0.001). This was corroborated by time-frequency maps. This study provides direct evidence of a cortical substrate to hypocapnic breathing in awake humans and fuels the notion of corticosubcortical cooperation to preserve human ventilation in a variety of situations. Of note, maintaining ventilatory activity at low carbon dioxide levels is among the prerequisites to speech production insofar as speech often induces hypocapnia.SIGNIFICANCE STATEMENTHuman ventilatory activity persists, during wakefulness, even when hypocapnia makes it unnecessary. This peculiarity of human breathing control is important to speech and speech-breathing insofar as speech induces hypocapnia. This study evidences a specific respiratory-related cortical activity. This suggests that human hypocapnic breathing is driven, at least in part, by cortical mechanisms similar to those involved in volitional breathing, in breathing against mechanical constraints or with weak inspiratory muscle, and in patients with defective medullary breathing pattern generators. This fuels the notion that the human ventilatory drive during wakefulness often results from a corticosubcortical cooperation, and opens new avenues to study certain ventilatory and speech disorders.
19 July 2016 in IEEE Transactions on Biomedical Engineering
Goal: During mechanical ventilation, patient-ventilator disharmony is frequently observed and may result in increased breathing effort, compromising the patient's comfort and recovery. This circumstance requires clinical intervention and becomes challenging when verbal communication is difficult. In this study, we propose a brain-computer interface (BCI) to automatically and noninvasively detect patient-ventilator disharmony from electroencephalographic (EEG) signals: a brain-ventilator interface (BVI). Methods: Our framework exploits the cortical activation provoked by the inspiratory compensation when the subject and the ventilator are desynchronized. Use of a one-class approach and Riemannian geometry of EEG covariance matrices allows effective classification of respiratory states. The BVI is validated on nine healthy subjects that performed different respiratory tasks that mimic a patient-ventilator disharmony. Results: Classification performances, in terms of areas under receiver operating characteristic curves, are significantly improved using EEG signals compared to detection based on air flow. Reduction in the number of electrodes that can achieve discrimination can be often desirable (e.g., for portable BCI systems). By using an iterative channel selection technique, the common highest order ranking, we find that a reduced set of electrodes (n = 6) can slightly improve for an intrasubject configuration, and it still provides fairly good performances for a general intersubject setting. Conclusion: Results support the discriminant capacity of our approach to identify anomalous respiratory states, by learning from a training set containing only normal respiratory epochs. Significance: The proposed framework opens the door to BVIs for monitoring patient's breathing comfort and adapting ventilator parameters to patient respiratory needs.
The recent embedding of electroencephalographic (EEG) electrodes in wearable devices raises the problem of the quality of the data recorded in such uncontrolled environments. These recordings are often obtained with dry single-channel EEG devices, and may be contaminated by many sources of noise which can compromise the detection and characterization of the brain state studied. In this paper, we propose a classification-based approach to effectively quantify artefact contamination in EEG segments, and discriminate muscular artefacts. The performance of our method were assessed on different databases containing either artificially contaminated or real artefacts recorded with different type of sensors, including wet and dry EEG electrodes. Furthermore, the quality of unlabelled databases was evaluated. For all the studied databases, the proposed method is able to rapidly assess the quality of the EEG signals with an accuracy higher than 90%. The obtained performance suggests that our approach provide an efficient, fast and automated quality assessment of EEG signals from low-cost wearable devices typically composed of a dry single EEG channel.
Objective. Time–frequency (T–F) analysis of electroencephalographic (EEG) is a common technique to characterise spectral changes in neural activity. This study explores the limitations of utilizing conventional spectral techniques in examining cyclic event-related cortical activities due to challenges, including high inter-trial variability. Approach. Introducing the cycle-frequency (C-F) analysis, we aim to enhance the evaluation of cycle-locked respiratory events. For synthetic EEG that mimicked cycle-locked pre-motor activity, C-F had more accurate frequency and time localization compared to conventional T–F analysis, even for a significantly reduced number of trials and a variability of breathing rhythm. Main results. Preliminary validations using real EEG data during both unloaded breathing and loaded breathing (that evokes pre-motor activity) suggest potential benefits of using the C-F method, particularly in normalizing time units to cyclic activity phases and refining baseline placement and duration. Significance. The proposed approach could provide new insights for the study of rhythmic neural activities, complementing T–F analysis.
Wearable EEG systems have become accessible to researchers and clinicians over the last decade, thus requiring neurotechnology companies to seek for outstanding EEG signal quality. Here, we show that the melomind™ headset equipped with dry electrodes (myBrain Technologies, Paris, France) allows the recording of reliable electro-cortical dynamics as compared to a wet-based standard-EEG system (actiCAP, Brain Products GmbH, Gilching, Germany). EEGs were acquired simultaneously from the two systems while thirteen subjects underwent a visual oddball, a steady-state visually-evoked potentials (SSVEPs) and two resting-state (RS) tasks. RS were acquired with eyes-closed and eyes-open (2 minutes each) and repeated twice (before and after the cognitive tasks). During the oddball task, participants responded on a gamepad when a target-stimulus was displayed. In the SSVEPs, visual responses were elicited at 15 and 20 Hz through a series of 15-second stimuli presented 5 times each. The power of theta- [4-8 Hz], alpha- [8-13 Hz], and beta- [13-30 Hz] band was extracted from the two RS. The signal-to-noise-ratio in the 15 (± 1) and 20 (± 1) Hz range was computed from the SSVEPs. The shape of the N2/P300 complex was analysed from the oddball task. Strong correlations resulted between the parameters obtained from the two EEG systems (0.53 < Pearson’s r < 0.97). Bland and Altman analysis revealed small dissimilarities between the two systems, with values laying in the 95% confidence interval in all the tasks. Our results demonstrate that the melomind™ is an affordable solution to reliably assess humans’ electro-cortical dynamics at-rest and during cognitive tasks, thus paving the way to its use in neuroscience studies and brain-computer interfaces.
Dyspnoea is frequent in mechanically ventilated patients and contributes to substantial distress and a heightened risk of post-traumatic stress disorder. It attests to respiratory-related brain suffering that must be actively managed. This is particularly challenging in noncommunicative patients, hence the interest of electroencephalographic surrogates. This study aims at characterizing the effects of opioids, proposed to relieve dyspnoea, on respiratory-related cortical activity in mechanically ventilated patients. In a 16-bed intensive care unit (ICU) over a 4-month period, we consecutively included eighteen mechanically ventilated patients with self-reported dyspnoea (visual analog scale -VAS-, communicative patients) or an observation-derived suspicion of respiratory-related brain suffering (noncommunicative patients, respiratory distress observation scores -RDOS-) persisting despite ventilator settings optimisation. Participants underwent electroencephalographic (EEG) recordings before and after administration of intravenous opioids. Respiratory-related cortical activity was assessed using covariance-based connectivity analysis, preinspiratory potentials (PIPs), and time-frequency analysis (TFA) time-locked to inspiration. To disentangle respiratory-specific from general effects of opioids, TFA was also computed from randomly selected EEG segments. Opioids reduced dyspnoea evaluated by VAS and RDOS without significant sedation. EEG covariance analysis showed changes in brain state in 15 of 18 patients. PIP occurrence was variable and not modulated by opioids. TFA revealed statistically significant opioid-induced modulations in low beta and high beta power bands time-locked to inspiration, not observed in randomly timed analyses hence a specific effect of opioids on respiratory-related cortical networks. Opioids can relieve dyspnoea in mechanically ventilated ICU patients and modulate respiratory-related cortical activity beyond their general effects on cortical electrogenesis. This suggests that their effects on breathing control are not limited to brainstem mechanisms.