Roshan Patel

Dr. Roshan Patel

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Journal of Endourology
Verified
Journal Article
Closed access
ZOZhamshid Okhunov
Zhamshid Okhunov
PJPengbo Jiang
Pengbo Jiang
AAAndrew Shea Afyouni
Andrew Shea Afyouni
MAMaged Ayad
Maged Ayad
RARaphael B. Arada
Raphael B. Arada
RCRalph V. Clayman
Ralph V. Clayman
Introduction: We sought to examine the intrarenal fluid and tissue temperature alterations during dusting and fragmentation with the thulium fiber laser (TFL) in an in vivo porcine kidney. Materials and Methods: In two female Yorkshire pigs, temperature was continuously measured within the upper, interpolar, and lower calices along with the renal pelvis using multipoint thermal sensor probes; another temperature probe was situated at the tip of the ureteroscope. Four experimental protocols were performed for each animal: dual lumen ureteroscope with both warmed (37°C) irrigation and room temperature (20°C–22°C) irrigation and single lumen ureteroscope with warmed and room temperature irrigation. Of note, in each pig, one kidney underwent ureteroscopy (URS) with a 14F ureteral access sheath (UAS) in place, whereas the other kidney had no UAS placed. A 200-μm TFL fiber was fired at three laser settings: (1) dusting at 0.5 J, 80 Hz (40 W) with continuous activation until 5 minutes expired or a temperature of 44°C was reached, (2) low-power fragmentation 1 J, 10 Hz, (10 W), and (3) high-power fragmentation at 1.5 J, 20 Hz (30 W). In all cases, the pulse width was 1 ms. For fragmentation, the laser was activated for 10 seconds with a 2-second intermission for a 1-minute period (five cycles). Results: In the absence of a UAS, in all but one circumstance, temperatures reached or exceeded 44°C at all laser settings with the use of either warm or room temperature irrigation fluid, regardless of the type of ureteroscope used. Of concern, temperatures recorded at the tip of the URS were 4°C to 22°C less than the temperatures recorded in the renal calices. In contrast, with a 14F UAS in place, six distinct groups had temperatures that did not exceed 44°C, specifically at low- and high-power fragmentation settings with room temperature irrigation for both sets of ureteroscopes and at dusting and low-power fragmentation settings with warm temperature irrigation solely for the single lumen ureteroscope. Temperatures recorded at the tip of the ureteroscope with the deployment of a UAS yielded temperature differences ranging from 17°C less to 19°C more than the renal calices. Conclusions: TFL is a novel laser technology for lithotripsy. In the absence of a UAS, high-power TFL fragmentation settings in particular may create temperatures within the collecting system that could result in urothelial tissue injury. Of note, peak temperatures recorded at the tip of the ureteroscope may misrepresent the actual intrarenal temperature during TFL laser lithotripsy.

1 February 2021 in Journal of Endourology
Verified
Journal Article
Closed access
DSDouglas Schneider
Douglas Schneider
GAGaren Abedi
Garen Abedi
KLKrista Larson
Krista Larson
MAMaged Ayad
Maged Ayad
RYRenai Yoon
Renai Yoon
RCRalph V. Clayman
Ralph V. Clayman
Introduction: Contemporary, flexible stone baskets are unable to extract submillimeter stone fragments at the time of ureteroscopic laser lithotripsy. In this in vitro study, the feasibility of suctioning submillimeter fragments with a standard Luer Lock syringe through the working channel of a flexible ureteroscope was assessed. Materials and Methods: Phantom stones made from industrial plaster were mechanically fragmented into ≤1 and ≤0.5-mm groups. Both stone groups were divided into five preweighed trial samples. Each stone group was then mixed in a beaker filled with normal saline. A standard 10-mL Luer Lock syringe was connected to a fiber-optic ureteroscope with a 1.2-mm working channel. The syringe was then used to suction stone fragments from the beaker. The suctioned stone fragments and the stone fragments remaining in the beaker after removing the overlying solution were separated, centrifuged with supernatant removed, and dried in an incubator set at 33°C for 1 week. Dried weights were recorded. Results: Mean total weights for ≤0.5 and ≤1.0-mm stone groups at baseline were 0.807 and 0.806 g, respectively. The mean percentages of stone fragments suctioned through the ureteroscope for ≤0.5 and ≤1.0-mm groups were 86% and 86%, respectively ( p = 0.973). During suctioning, 64% of stones in the ≤0.5-mm group were trapped in either the working channel of the ureteroscope or within the Luer Lock syringe compared with 78% of stones in the ≤1-mm group ( p = 0.001) requiring cessation of the procedure to clear the channel. Conclusions: It is feasible to suction submillimeter stone fragments by connecting a Luer Lock syringe to the working channel of a flexible ureteroscope. The limiting factor for removing stone fragments appears to be the small working channel of flexible ureteroscopes as trapping of fragments during suctioning is common and requires time-consuming removal of the endoscope and clearing of the channel.

1 October 2024 in Journal of Endourology
Verified
Journal Article
Closed access
BGBruce Gao
Bruce Gao
JTJacob C. Tsai
Jacob C. Tsai
ACAndrei D. Cumpanas
Andrei D. Cumpanas
JAJaime Altamirano-Villarroel
Jaime Altamirano-Villarroel
SSSeyedamirvala Saadat
Seyedamirvala Saadat
RCRalph V. Clayman
Ralph V. Clayman
Purpose: Retrograde intrarenal surgery is the gold-standard treatment for most kidney stones. During ureteroscopy, ureteral access sheath insertion at forces greater than 8.0 Newtons (N) risks high-grade ureteral injury. To monitor force, our institution utilizes a unique, Bluetooth-equipped device (i.e., the University of California—Irvine Force Sensor). Given the unique nature of the force sensor, we sought to develop an inexpensive and accessible force sensor based on Boyle’s law and the specific amount of force required to compress an occluded 1.0 mL syringe. Materials and Methods: We evaluated three brands of 1.0 mL syringes. After setting the plunger at 1.0 mL, the syringe was occluded, and the syringe plunger was compressed. The syringe volume was recorded when the applied force on the plunger reached 4.0 N, 6.0 N, and 8.0 N. Multiple trials were performed to assess reliability and reproducibility. A method for applying this clinically was also developed. Results: The precise force thresholds identified for a 1.0 mL Luer-Lok™ Syringe (Becton Dickinson, Franklin Lakes, NJ) were 0.30 mL for 4.00 N, 0.20 mL for 6.00 N, and 0.15 mL for 8.00 N. The 1.0 mL Tuberculin Syringe and 1.0 mL Luer Slip Syringe were less precise, but compression from 1.0 to 0.40 mL, 0.25 mL, and 0.20 mL corresponded to force sensor readings that did not exceed 4.00 N, 6.00 N, and 8.00 N, respectively. Conclusions: Based on volume changes, 4.00 N, 6.00 N, and 8.00 N of force can be reliably and reproducibly achieved using an occluded 1.0 mL syringe.

1 September 2023 in Journal of Endourology
Verified
Journal Article
Closed access
RBRohit Bhatt
Rohit Bhatt
KVKelvin Vo
Kelvin Vo
ACAndrei Dragos Cumpanas
Andrei Dragos Cumpanas
KMKalon L. Morgan
Kalon L. Morgan
ASAndrew Shin
Andrew Shin
JLJaime Landman
Jaime Landman
Introduction: The metal-based Resonance stent (RS) has traditionally been placed in patients with malignant ureteral obstruction; as such, the long-term utility of RS among patients with benign ureteral obstruction (BUO) remains underinvestigated. Methods: We retrospectively reviewed our database for patients with BUO who underwent RS placement between 2010 and 2020. The impact of chronic RS placement on renal function was evaluated by estimated serum creatinine-based glomerular filtration rate (eGFR), furosemide renal scan, and CT-based renal parenchymal volume measurement. The number of and reason for RS stent exchanges during the follow-up period, incidence of encrustation, and the average indwell time were recorded. A cost analysis of placing the RS vs a polymeric stent was performed. Results: Among 43 RS patients with BUO, at a mean follow-up of 26 months, there was no change in eGFR ( p = 0.99), parenchymal volume ( p = 0.44), or split renal function of the stent-bearing side on renal scan ( p = 0.48). The mean RS indwell time was 9.7 months. Eleven patients (26%) underwent premature stent replacement (6 cases) or removal (5 cases). Stents in 9 patients (32%) were encrusted, of which 4 (44%) required laser lithotripsy. Overall, 25 patients (58%) and 12 patients (28%) had a mean stent indwell time of ≥6 months and ≥12 months, respectively. Placing an RS resulted in a 52%, 37%, and 5.6% cost reduction compared with a regular polymeric stent placement, where it was exchanged every 6, 4, or 3 months, respectively. Conclusions: RS deployment in the patient with a BUO results in cost-effective maintenance of renal function and of renal parenchymal volume at a mean follow-up of 2 years; however, only 28% of patients fulfilled the 1-year criterion for RS indwell time.

21 February 2025 in Lasers in Medical Science
Verified
Journal Article
Closed access
PDF file
ACAndrei D. Cumpanas
Andrei D. Cumpanas
NKNitesh Katta
Nitesh Katta
TVThao N. Vu
Thao N. Vu
YWYi Xi Wu
Yi Xi Wu
AGAntonio R. H. Gorgen
Antonio R. H. Gorgen
RCRalph V. Clayman
Ralph V. Clayman

14 June 2023 in Journal of Endourology
Verified
Journal Article
Closed access
SSSeyed Hossein Hosseini Sharifi
Seyed Hossein Hosseini Sharifi
SASohrab Naushad Ali
Sohrab Naushad Ali
YWYi Xi Wu
Yi Xi Wu
ZTZachary Edward Tano
Zachary Edward Tano
SLSeyed Amiryaghoub M. Lavasani
Seyed Amiryaghoub M. Lavasani
RCRalph V. Clayman
Ralph V. Clayman
Introduction: Electromotive Drug Administration (EMDA) delivers a drug deeply into targeted tissues, such as the bladder. EMDA has never been applied to the ureter. Methods: In four in vivo porcine ureters, a unique EMDA catheter containing a silver conducting wire was advanced for the infusion of methylene blue. In two ureters, a pulsed current was delivered via an EMDA machine, while the other two ureters served as a control. After 20 minutes of infusion, the ureters were harvested. Results: In the EMDA ureter, there was diffuse staining of the urothelium; penetration of methylene blue occurred in the lamina propria and muscularis propria. In the control ureter, there was only patchy staining of the urothelium. Conclusion: In this first report of ureteral EMDA, a charged molecule penetrated beyond the urothelium into the lamina propria and muscularis propria of the porcine ureter.