Simone Sala

Dr. Simone Sala

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2017 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
Marie-Christine ZdoraMarie-Christine Zdora
Marie-Christine Zdora
PTPierre Thibault
Pierre Thibault
TZTunhe Zhou
Tunhe Zhou
FKFrieder J. Koch
Frieder J. Koch
JRJenny Romell
Jenny Romell
IZIrene Zanette
Irene Zanette
We present a method for x-ray phase-contrast imaging and metrology applications based on the sample-induced modulation and subsequent computational demodulation of a random or periodic reference interference pattern. The proposed unified modulated pattern analysis (UMPA) technique is a versatile approach and allows tuning of signal sensitivity, spatial resolution, and scan time. We characterize the method and demonstrate its potential for high-sensitivity, quantitative phase imaging, and metrology to overcome the limitations of existing methods.

5 October 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
UJUlf Johansson
Ulf Johansson
DCDina Carbone
Dina Carbone
SKSebastian Kalbfleisch
Sebastian Kalbfleisch
ABAlexander Björling
Alexander Björling
MKMaik Kahnt
Maik Kahnt
UVUlrich Vogt
Ulrich Vogt
NanoMAX is the first hard X-ray nanoprobe beamline at the MAX IV laboratory. It utilizes the unique properties of the world's first operational multi-bend achromat storage ring to provide an intense and coherent focused beam for experiments with several methods. In this paper we present the beamline optics design in detail, show the performance figures, and give an overview of the surrounding infrastructure and the operational diffraction endstation.

7 February 2020 in Optics Express
Verified
Journal Article
Closed access
ABAlexander Björling
Alexander Björling
SKSebastian Kalbfleisch
Sebastian Kalbfleisch
MKMaik Kahnt
Maik Kahnt
SSSimone Sala
Simone Sala
KPKarolis Parfeniukas
Karolis Parfeniukas
UJUlf Johansson
Ulf Johansson
The NanoMAX hard X-ray nanoprobe is the first beamline to take full advantage of the diffraction-limited storage ring at the MAX IV synchrotron and delivers a high coherent photon flux for applications in diffraction and imaging. Here, we characterize its coherent and focused beam using ptychographic analysis. We derive beam profiles in the energy range 6-22 keV and estimate the coherent flux based on a probe mode decomposition approach.

16 March 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
DCDina Carbone
Dina Carbone
SKSebastian Kalbfleisch
Sebastian Kalbfleisch
UJUlf Johansson
Ulf Johansson
ABAlexander Björling
Alexander Björling
MKMaik Kahnt
Maik Kahnt
LRLinus Roslund
Linus Roslund
The diffraction endstation of the NanoMAX beamline is designed to provide high-flux coherent X-ray nano-beams for experiments requiring many degrees of freedom for sample and detector. The endstation is equipped with high-efficiency Kirkpatrick–Baez mirror focusing optics and a two-circle goniometer supporting a positioning and scanning device, designed to carry a compact sample environment. A robot is used as a detector arm. The endstation, in continued development, has been in user operation since summer 2017.

8 January 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
SSSimone Sala
Simone Sala
DBDarren J. Batey
Darren J. Batey
APAnupama Prakash
Anupama Prakash
SASharif Ahmed
Sharif Ahmed
CRChristoph Rau
Christoph Rau
PTPierre Thibault
Pierre Thibault
Ptychographic X-ray computed tomography is a phase-contrast imaging technique capable of retrieving three-dimensional maps of the index of refraction of the imaged volumes with nanometric resolution. Despite its unmatched reach, its application remains prerogative of a limited number of laboratories at synchrotron sources. We present a detailed description of an experimental procedure and a data analysis pipeline which can be both exploited for ptychographic X-ray computed tomography experiments at any high-brilliance X-ray source. These have been validated at the I13-1 Coherence Branchline within the first experiment of its kind to be successfully carried out on a biological sample at Diamond Light Source.

12 April 2021 in Optica
Verified
Journal Article
Closed access
BDBenedikt J. Daurer
Benedikt J. Daurer
SSSimone Sala
Simone Sala
MHMax F. Hantke
Max F. Hantke
HRHemanth K. N. Reddy
Hemanth K. N. Reddy
JBJohan Bielecki
Johan Bielecki
PTPierre Thibault
Pierre Thibault
A well-characterized wavefront is important for many x-ray free-electron laser (XFEL) experiments, especially for single-particle imaging (SPI), where individual biomolecules randomly sample a nanometer region of highly focused femtosecond pulses. We demonstrate high-resolution multiple-plane wavefront imaging of an ensemble of XFEL pulses, focused by Kirkpatrick–Baez mirrors, based on mixed-state ptychography, an approach letting us infer and reduce experimental sources of instability. From the recovered wavefront profiles, we show that while local photon fluence correction is crucial and possible for SPI, a small diversity of phase tilts likely has no impact. Our detailed characterization will aid interpretation of data from past and future SPI experiments and provides a basis for further improvements to experimental design and reconstruction algorithms.