Florian Schröper

Dr. Florian Schröper

Fraunhofer Institute for Molecular Biology and Applied Ecology IME, Bolecular Biotechnology, Aachen, Germany
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2008 in Electrochimica Acta
Verified
Journal Article
Closed access
Florian SchröperFlorian Schröper
Florian Schröper
DBDorothea Brüggemann
Dorothea Brüggemann
YMYulia G. Mourzina
Yulia G. Mourzina
BWBernhard Wolfrum
Bernhard Wolfrum
AOAndreas Offenhäusser
Andreas Offenhäusser
DMDirk Mayer
Dirk Mayer

1 May 2015 in Applied and Environmental Microbiology
Verified
Journal Article
Open access
PDF file
SRStefanie Rettcher
Stefanie Rettcher
FJFelicitas Jungk
Felicitas Jungk
CKChristoph Kühn
Christoph Kühn
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
GNGreta Nölke
Greta Nölke
Florian SchröperFlorian Schröper
Florian Schröper
Plant pathogens cause major economic losses in the agricultural industry because late detection delays the implementation of measures that can prevent their dissemination. Sensitive and robust procedures for the rapid detection of plant pathogens are therefore required to reduce yield losses and the use of expensive, environmentally-damaging chemicals. Here we describe a simple and portable system for the rapid detection of viral pathogens in infected plants, based on immunofiltration, subsequent magnetic detection and the quantification of magnetically-labeled virus particles. Grapevine fanleaf virus (GFLV) was chosen as a model pathogen. Monoclonal antibodies recognizing the GFLV capsid protein were immobilized onto immunofiltration columns and the same antibodies were linked to magnetic nanoparticles. GFLV was quantified by immunofiltration with magnetic labeling in a double antibody sandwich configuration. A magnetic frequency mixing technique was used for high-sensitivity quantification, in which a two-frequency magnetic excitation field was used to induce a sum-frequency signal in the resonant detection coil, corresponding to the virus concentration within the immunofiltration column. We were able to measure GFLV concentrations in the range 6 ng/mL to 20 μg/mL in less than 30 min. The magnetic immunoassay could also be adapted to detect other plant viruses, including Potato virus X and Tobacco mosaic virus, with detection limits of 2–60 ng/mL.

30 November 2020 in Foods
Verified
Journal Article
Open access
PDF file
JPJan Pietschmann
Jan Pietschmann
DDDominik Dittmann
Dominik Dittmann
HSHolger Spiegel
Holger Spiegel
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
Florian SchröperFlorian Schröper
Florian Schröper
The misuse of antibiotics as well as incorrect dosage or insufficient time for detoxification can result in the presence of pharmacologically active molecules in fresh milk. Hence, in many countries, commercially available milk has to be tested with immunological, chromatographic or microbiological analytical methods to avoid consumption of antibiotic residues. Here a novel, sensitive and portable assay setup for the detection and quantification of penicillin and kanamycin in whole fat milk (WFM) based on competitive magnetic immunodetection (cMID) is described and assay accuracy determined. For this, penicillin G and kanamycin-conjugates were generated and coated onto a matrix of immunofiltration columns (IFC). Biotinylated penicillin G or kanamycin-specific antibodies were pre-incubated with antibiotics-containing samples and subsequently applied onto IFC to determine the concentration of antibiotics through the competition of antibody-binding to the antibiotic-conjugate molecules. Bound antibodies were labeled with streptavidin-coated magnetic particles and quantified using frequency magnetic mixing technology. Based on calibration measurements in WFM with detection limits of 1.33 ng·mL−1 for penicillin G and 1.0 ng·mL−1 for kanamycin, spiked WFM samples were analyzed, revealing highly accurate recovery rates and assay precision. Our results demonstrate the suitability of cMID-based competition assay for reliable and easy on-site testing of milk.

5 July 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SAStefan Achtsnicht
Stefan Achtsnicht
CNChristian Neuendorf
Christian Neuendorf
TFTobias Faßbender
Tobias Faßbender
GNGreta Nölke
Greta Nölke
AOAndreas Offenhäusser
Andreas Offenhäusser
Florian SchröperFlorian Schröper
Florian Schröper
Cholera is a life-threatening disease caused by the cholera toxin (CT) as produced by some Vibrio cholerae serogroups. In this research we present a method which directly detects the toxin’s B subunit (CTB) in drinking water. For this purpose we performed a magnetic sandwich immunoassay inside a 3D immunofiltration column. We used two different commercially available antibodies to capture CTB and for binding to superparamagnetic beads. ELISA experiments were performed to select the antibody combination. The beads act as labels for the magnetic frequency mixing detection technique. We show that the limit of detection depends on the type of magnetic beads. A nonlinear Hill curve was fitted to the calibration measurements by means of a custom-written python software. We achieved a sensitive and rapid detection of CTB within a broad concentration range from 0.2 ng/ml to more than 700 ng/ml.

20 May 2020 in Toxins
Verified
Journal Article
Open access
PDF file
JPJan Pietschmann
Jan Pietschmann
HSHolger Spiegel
Holger Spiegel
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
SSStefan Schillberg
Stefan Schillberg
Florian SchröperFlorian Schröper
Florian Schröper
Food and crop contaminations with mycotoxins are a severe health risk for consumers and cause high economic losses worldwide. Currently, different chromatographic- and immuno-based methods are used to detect mycotoxins within different sample matrices. There is a need for novel, highly sensitive detection technologies that avoid time-consuming procedures and expensive laboratory equipment but still provide sufficient sensitivity to achieve the mandated detection limit for mycotoxin content. Here we describe a novel, highly sensitive, and portable aflatoxin B1 detection approach using competitive magnetic immunodetection (cMID). As a reference method, a competitive ELISA optimized by checkerboard titration was established. For the novel cMID procedure, immunofiltration columns, coated with aflatoxin B1-BSA conjugate were used for competitive enrichment of biotinylated aflatoxin B1-specific antibodies. Subsequently, magnetic particles functionalized with streptavidin can be applied to magnetically label retained antibodies. By means of frequency mixing technology, particles were detected and quantified corresponding to the aflatoxin content in the sample. After the optimization of assay conditions, we successfully demonstrated the new competitive magnetic detection approach with a comparable detection limit of 1.1 ng aflatoxin B1 per mL sample to the cELISA reference method. Our results indicate that the cMID is a promising method reducing the risks of processing contaminated commodities.

1 April 2012 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Florian SchröperFlorian Schröper
Florian Schröper
ABArnd Baumann
Arnd Baumann
AOAndreas Offenhäusser
Andreas Offenhäusser
DMDirk Mayer
Dirk Mayer