This work explores and evaluates the effect of diffuse light reflection on the accuracy of indoor localization systems based on visible light communication (VLC) in a high reflectivity environment using a received signal strength indication (RSSI) technique. The effect of the essential receiver (Rx) and transmitter (Tx) parameters on the localization error with different transmitted LED power and wall reflectivity factors is investigated at the worst Rx coordinates for a directed/overall link. Since this work assumes harsh operating conditions (i.e., a multipath model, high reflectivity surfaces, worst Rx position), an error of ≥ 1.46 m is found. To achieve a localization error in the range of 30 cm under these conditions with moderate LED power (i.e., P = 0.45 W), low reflectivity walls (i.e., ρ = 0.1) should be used, which would enable a localization error of approximately 7 mm at the room’s center.
This review summarizes recent advances in sensors based on photonic crystal technologies for biomedical sensing applications. Photonic crystal sensing offers enormous promise due to their clear benefits in sensitivity, stability, compactness, portability. This work discusses several photonic crystal structures, such as photonic crystal waveguides, cavities, and photonic crystal fiber for biomedical sensing applications. The uniqueness, measurement technique, and biosensing properties of each type of these structures are discussed. Furthermore, manufacturing and functionally relevant properties that include design simplicity, compactness, and multi-wavelength operation are also reviewed. They are explored, organized, and compared using the most recent related literature in this field. Finally, a brief of novel trends has been introduced.
In this paper, a novel two-dimensional photonic crystal based all-optical AND/OR logic gates are designed, simulated and optimized. The structure is built on a linear square lattice photonic crystal platform. A multi-wavelength operation, together with a simultaneous operation, is achieved at ultra-high bit rates. The concurrent operation is attained without altering the proposed design continuously, as stated in the literature. It provides simplicity because there is no auxiliary input required along with the absence of externally attached phase shift units. The enhancement process has been done to the rod radius. A magnificent representation tool is developed. The benefit of the mentioned tool lies in the data combination of different operating wavelengths, contrast ratio, and bit rate; which will establish an efficient optimization process. Each gate is enhanced independently, then an overall improvement has been done. As a result, the operation at 1.52 µm will provide a successful multi logic gate operation with ultra-high bit rates of 6.76 and 4.74 Tbit/s for AND and OR logic gates, respectively. The design has an acceptable size of (19.8 × 12.6 µm) and a contrast ratio of 9.74 dB and 17.95 dB for the designed AND and OR gate, respectively. The design is highly sensitive to the waveguide length to verify the gates on demand.
In this work, different FBG temperature sensors are designed and evaluated with various apodization profiles. Evaluation is done under a wide range of controlling design parameters like sensor length and refractive index modulation amplitude, targeting a remarkable temperature sensing performance. New judgment techniques are introduced such as apodization window roll-off rate, asymptotic sidelobe (SL) decay level, number of SLs, and average SL level (SLav). Evaluation techniques like reflectivity, Full width at Half Maximum (FWHM), and Sidelobe Suppression Ratio (SLSR) are also used. A “New” apodization function is proposed, which achieves better performance like asymptotic decay of 18.4 dB/nm, high SLSR of 60 dB, high channel isolation of 57.9 dB, and narrow FWHM less than 0.15 nm. For a single accurate temperature sensor measurement in extensive noisy environment, optimum results are obtained by the Nuttall apodization profile and the new apodization function, which have remarkable SLSR. For a quasi-distributed FBG temperature sensor the Barthann and the new apodization profiles obtain optimum results. Barthann achieves a high asymptotic decay of 40 dB/nm, a narrow FWHM (less than 25 GHZ), a very low SLav of −45.3 dB, high isolation of 44.6 dB, and a high SLSR of 35 dB. The new apodization function achieves narrow FWHM of 0.177 nm, very low SL of −60.1, very low SLav of −63.6 dB, and very high SLSR of −57.7 dB. A study is performed on including an unapodized sensor among apodized sensors in a quasi-distributed sensing system. Finally, an isolation examination is performed on all the discussed apodizations and a linear relation between temperature and the Bragg wavelength shift is observed experimentally and matched with the simulated results.