In the electric distribution systems, the “Smart Grid” concept is implemented to encourage energy savings and integration of the innovative technologies, helping the distribution network operators (DNOs) in choosing the investment plans which lead to the optimal operation of the networks and increasing the energy efficiency. In this context, a new phase load balancing algorithm was proposed to be implemented in the low voltage distribution networks with hybrid structures of the consumption points (switchable and non-switchable consumers). It can work in both operation modes (real-time and off-line), uploading information from different databases of the DNO which contain: The consumers’ characteristics, the real loads of the consumers integrated into the smart metering system (SMS), and the typical load profiles for the consumers non-integrated in the SMS. The algorithm was tested in a real network, having a hybrid structure of the consumption points, on a by 24-h interval. The obtained results were analyzed and compared with other algorithms from the heuristic (minimum count of loads adjustment algorithm) and the metaheuristic (particle swarm optimization and genetic algorithms) categories. The best performances were provided by the proposed algorithm, such that the unbalance coefficient had the smallest value (1.0017). The phase load balancing led to the following technical effects: decrease of the average current in the neutral conductor and the energy losses with 94%, respectively 61.75%, and increase of the minimum value of the phase voltage at the farthest pillar with 7.14%, compared to the unbalanced case.
Photovoltaic hosting capacity in low-voltage (LV) networks is usually assessed with balanced or three-wire models, although much of European rural distribution is four-wire with predominantly single-phase connections, where the neutral couples the phases and the voltage response to an injection depends on the phase of the injecting unit. This paper derives that dependence in closed form and builds a coordinated curtailment scheme on it. The test system is a 250 kVA rural substation in north-eastern Romania with 213 supply points, 95.3% of them single-phase, and 53 prosumers, whose feeder, pole and phase are taken from operator records. A four-wire power flow including the EN 50549-1 trip and reconnection sequence compares six inverter strategies with a proposed Trip-Aware Positive-Neighbour Control (PNC), in which the operator releases a per-inverter power ceiling at each averaging window and tightens it only on units with positive voltage sensitivity. The critical-node sensitivity is +3.294 V/kW on the injecting phase and negative on the other two, so only 35 of the 53 units can relieve it, and its sign depends on the power factor. Reactive absorption drives the non-generating phases to 202.0 V at midday. PNC and a local P(U) droop both reach 500 kWp, twice the transformer rating, but PNC curtails 23% less energy and keeps a Jain fairness index of 0.930 against 0.850. Prosumer phase allocation alone is worth 44% of the curtailed energy.