Brieg Dissaux

Dr. Brieg Dissaux


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
BDBrieg Dissaux
Brieg Dissaux
FEF. Eugène
F. Eugène
Julien OgnardJulien Ognard
Julien Ognard
JGJ.-Y. Gauvrit
J.-Y. Gauvrit
JGJ.-C. Gentric
J.-C. Gentric
JFJ.-C. Ferré
J.-C. Ferré
BACKGROUND AND PURPOSE: 4D contrast-enhanced MRA in the follow-up of treated dural arteriovenous fistulas has rarely been evaluated. Our aim was to evaluate its diagnostic performance at 3T in the follow-up of embolized dural arteriovenous fistulas using DSA as the standard of reference. MATERIALS AND METHODS: Patients treated for dural arteriovenous fistulas in 2 centers between 2008 and 2019 were included if they met the following criteria: 1) dural arteriovenous fistula embolization, and 2) follow-up imaging with <6 months between DSA and 4D contrast-enhanced MRA. Two readers reviewed the 4D contrast-enhanced MRA images, first independently, then in consensus to detect any residual/recurrent dural arteriovenous fistula and to grade cases according to the Cognard classification system. Interobserver and intermodality agreement for the detection of a residual dural arteriovenous fistula and stratification of bleeding risk (0-I-IIa; IIb-IIa+b-III-IV-V) was calculated using κ coefficients. RESULTS: A total of 51 pairs of examinations for 44 patients (median age, 65 years; range, 25–81 years) were analyzed. Interobserver agreement for the detection and stratification of bleeding risk was, respectively, κ = 0.8 (95% CI, 0.6–1) and κ = 0.8 (95% CI, 0.5–1). After consensus review, the sensitivity and specificity of 4D contrast-enhanced MRA for the detection of residual/recurrent dural arteriovenous fistula was 63.6% (95% CI, 40.7%–82.8%) and 96.6% (95% CI, 82.2%–99.9%), respectively. The positive and negative predictive values of 4D contrast-enhanced MRA were 93.3% (95% CI, 68.1%–99.8%) and 77.8% (95% CI, 60.8%–89.9%). Intermodality agreement for the detection and stratification of bleeding risk was good, with κ = 0.60 (95% CI, 0.3–0.8). CONCLUSIONS: 4D contrast-enhanced MRA at 3T is of interest in the follow-up of treated dural arteriovenous fistulas but lacks the sensitivity to replace arteriography.

7 November 2019 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
BDBrieg Dissaux
Brieg Dissaux
Julien OgnardJulien Ognard
Julien Ognard
MAMourad Cheddad El Aouni
Mourad Cheddad El Aouni
MNMichel Nonent
Michel Nonent
KHKarim Haioun
Karim Haioun
JGJean Christophe Gentric
Jean Christophe Gentric
​Background and purpose Intracranial aneurysms are a frequently occurring disease, with an estimated prevalence of 2–5% in the general population. They usually remain silent until rupture occurs, with a mortality rate of 35–50% and a high rate of morbidity, including long-term disability. However, preventative treatments have their own risk of complications and morbi-mortality rates, including stroke and hemorrhage. ECG-gated four-dimensional CT angiography (4D-CTA) allows the acquisition of time-resolved three-dimensional reconstructions. The aim of our study was to evaluate different intracranial aneurysm metrics over the cardiac cycle using ECG-gated 4D-CTA. ​Materials and methods ECG-gated 4D-CTA datasets were acquired in patients presenting with intracranial aneurysms. Seven aneurysm metrics, including aneurysm height, aneurysm length, ostium width, aspect ratio, ostium area, volume, and volume-to-ostium ratio, were analysed over different cardiac phases. Intra-reader agreement, inter-reader agreement, and inter-cycle agreement were calculated through the intraclass correlation coefficient. ​Results Twenty-one aneurysms from 11 patients were considered for inclusion. Post-processing failed for three aneurysms, and 18 aneurysms were finally analysed. There was good intra-reader agreement for each metric (ICC >0.9). Agreements among three consecutive cardiac cycles were calculated for six aneurysms and were especially good for the volume metric (ICC >0.9). Volume variation appears to be the most relevant metric and seems especially perceptible for aneurysms larger than 5 mm. ​Conclusions Quantification of aneurysm volume changes during the cardiac cycle seems quantitatively possible and reproducible, especially for aneurysms larger than 5 mm. Further studies need to be conducted to validate this parameter for intracranial aneurysm assessment.

23 December 2022 in Cancers
Verified
Journal Article
Open access
PDF file
BABastien Allard
Bastien Allard
BDBrieg Dissaux
Brieg Dissaux
DBDavid Bourhis
David Bourhis
GDGurvan Dissaux
Gurvan Dissaux
USUlrike Schick
Ulrike Schick
SQSolène Querellou
Solène Querellou
The standard therapy strategy for high-grade glioma (HGG) is based on the maximal surgery followed by radio-chemotherapy (RT-CT) with insufficient control of the disease. Recurrences are mainly localized in the radiation field, suggesting an interest in radiotherapy dose escalation to better control the disease locally. We aimed to identify a similarity between the areas of high uptake on O-(2-[18F]-fluoroethyl)-L-tyrosine (FET) positron emission tomography/computed tomography (PET) before RT-CT, the residual tumor on post-therapy NADIR magnetic resonance imaging (MRI) and the area of recurrence on MRI. This is an ancillary study from the IMAGG prospective trial assessing the interest of FET PET imaging in RT target volume definition of HGG. We included patients with diagnoses of HGG obtained by biopsy or tumor resection. These patients underwent FET PET and brain MRIs, both after diagnosis and before RT-CT. The follow-up consisted of sequential brain MRIs performed every 3 months until recurrence. Tumor delineation on the initial MRI 1 (GTV 1), post-RT-CT NADIR MRI 2 (GTV 2), and progression MRI 3 (GTV 3) were performed semi-automatically and manually adjusted by a neuroradiologist specialist in neuro-oncology. GTV 2 and GTV 3 were then co-registered on FET PET data. Tumor volumes on FET PET (MTV) were delineated using a tumor to background ratio (TBR) ≥ 1.6 and different % SUVmax PET thresholds. Spatial similarity between different volumes was performed using the dice (DICE), Jaccard (JSC), and overlap fraction (OV) indices and compared together in the biopsy or partial surgery group (G1) and the total or subtotal surgery group (G2). Another overlap index (OV’) was calculated to determine the threshold with the highest probability of being included in the residual volume after RT-CT on MRI 2 and in MRI 3 (called “hotspot”). A total of 23 patients were included, of whom 22% (n = 5) did not have a NADIR MRI 2 due to a disease progression diagnosed on the first post-RT-CT MRI evaluation. Among the 18 patients who underwent a NADIR MRI 2, the average residual tumor was approximately 71.6% of the GTV 1. A total of 22% of patients (5/23) showed an increase in GTV 2 without diagnosis of true progression by the multidisciplinary team (MDT). Spatial similarity between MTV and GTV 2 and between MTV and GTV 3 were higher using a TBR ≥ 1.6 threshold. These indices were significantly better in the G1 group than the G2 group. In the FET hotspot analysis, the best similarity (good agreement) with GTV 2 was found in the G1 group using a 90% SUVmax delineation method and showed a trend of statistical difference with those (poor agreement) in the G2 group (OV’ = 0.67 vs. 0.38, respectively, p = 0.068); whereas the best similarity (good agreement) with GTV 3 was found in the G1 group using a 80% SUVmax delineation method and was significantly higher than those (poor agreement) in the G2 group (OV’= 0.72 vs. 0.35, respectively, p = 0.014). These results showed modest spatial similarity indices between MTV, GTV 2, and GTV 3 of HGG. Nevertheless, the results were significantly improved in patients who underwent only biopsy or partial surgery. TBR ≥ 1.6 and 80–90% SUVmax FET delineation methods showing a good agreement in the hotspot concept for targeting standard dose and radiation boost. These findings need to be tested in a larger randomized prospective study.

4 March 2024 in Surgical and Radiologic Anatomy
Verified
Journal Article
Closed access
PDF file
BDBrieg Dissaux
Brieg Dissaux
MDMarie Duigou
Marie Duigou
MHMatthias Herteleer
Matthias Herteleer
CLChristian Lefèvre
Christian Lefèvre
PBPatrick Baqué
Patrick Baqué
RSRomuald Seizeur
Romuald Seizeur

8 August 2023 in Surgical and Radiologic Anatomy
Verified
Journal Article
Closed access
PDF file
BDBrieg Dissaux
Brieg Dissaux
JOJulien Ognard
Julien Ognard
BLBran Léger
Bran Léger
MDMarie Duigou
Marie Duigou
CLChristian Lefèvre
Christian Lefèvre
RSRomuald Seizeur
Romuald Seizeur

16 August 2022 in Tomography
Verified
Journal Article
Open access
PDF file
BDBrieg Dissaux
Brieg Dissaux
DFDoria Mazouz Fatmi
Doria Mazouz Fatmi
Julien OgnardJulien Ognard
Julien Ognard
BABastien Allard
Bastien Allard
NKNathalie Keromnes
Nathalie Keromnes
SQSolène Querellou
Solène Querellou
Background: The aim of this prospective monocentric study was to assess the inter-observer agreement for tumor volume delineations by multiparametric MRI and 18-F-FET-PET/CT in newly diagnosed, untreated high-grade glioma (HGG) patients. Methods: Thirty patients HGG underwent O-(2-[18F]-fluoroethyl)-l-tyrosine(18F-FET) positron emission tomography (PET), and multiparametric MRI with computation of rCBV map and K2 map. Three nuclear physicians and three radiologists with different levels of experience delineated the 18-F-FET-PET/CT and 6 MRI sequences, respectively. Spatial similarity (Dice and Jaccard: DSC and JSC) and overlap (Overlap: OV) coefficients were calculated between the readers for each sequence. Results: DSC, JSC, and OV were high for 18F-FET PET/CT, T1-GD, and T2-FLAIR (>0.67). The Spearman correlation coefficient between readers was ≥0.6 for these sequences. Cross-comparison of similarity and overlap parameters showed significant differences for DSC and JSC between 18F-FET PET/CT and T2-FLAIR and for JSC between 18F-FET PET/CT and T1-GD with higher values for 18F-FET PET/CT. No significant difference was found between T1-GD and T2-FLAIR. rCBV, K2, b1000, and ADC showed correlation coefficients between readers <0.6. Conclusion: The interobserver agreements for tumor volume delineations were high for 18-F-FET-PET/CT, T1-GD, and T2-FLAIR. The DWI (b1000, ADC), rCBV, and K2-based sequences, as performed, did not seem sufficiently reproducible to be used in daily practice.