Carmine Granata

Dr. Carmine Granata

National Research Council (CNR), Institute of Applied Sciences and Intelligent Systems
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in Physics Reports
Verified
Journal Article
Closed access
CGCarmine Granata
Carmine Granata
AVAntonio Vettoliere
Antonio Vettoliere

27 May 2008 in Nanotechnology
Verified
Journal Article
Closed access
CGCarmine Granata
Carmine Granata
Emanuela EspositoEmanuela Esposito
Emanuela Esposito
AVAntonio Vettoliere
Antonio Vettoliere
LPL Petti
L Petti
MRM Russo
M Russo
An integrated magnetic nanosensor based on a niobium dc SQUID (superconducting quantum interference device) for nanoscale applications is presented. The sensor, having a washer shape with a hole of 200 nm and two Josephson-Dayem nanobridges of 80 nm × 100 nm, consists of a Nb(30 nm)/Al(30 nm) bilayer patterned by electron beam lithography (EBL) and shaped by lift-off and reactive ion etch (RIE) processes. The presence of the niobium coils, integrated on-chip and tightly coupled to the SQUID, allows us to easily excite the sensor in order to get the voltage-flux characteristics and to flux bias the SQUID at its optimal point. The measurements were performed at liquid helium temperature. A voltage swing of 75 µV and a maximum voltage-flux transfer coefficient (responsivity) as high as 1 mV/Φ(0) were directly measured from the voltage-flux characteristic. The noise measurements were performed in open loop mode, biasing the SQUID with a dc magnetic flux at its maximum responsivity point and using direct-coupled low-noise readout electronics. A white magnetic flux noise spectral density as low as 2.5 μΦ(0) Hz(-1/2) was achieved, corresponding to a magnetization or spin sensitivity in units of the Bohr magneton of 100 spin Hz(-1/2). Possible applications of this nanosensor can be envisaged in magnetic detection of nanoparticles and small clusters of atoms and molecules, in the measurement of nanoobject magnetization, and in quantum computing.

25 November 2007 in Nature Physics
Verified
Journal Article
Closed access
SFSergey M. Frolov
Sergey M. Frolov
MSMicah J. A. Stoutimore
Micah J. A. Stoutimore
TCTrevis A. Crane
Trevis A. Crane
DHDale J. Van Harlingen
Dale J. Van Harlingen
VOVladimir A. Oboznov
Vladimir A. Oboznov
MRMaurizio Russo
Maurizio Russo

1 May 2000 in Philosophical Magazine Part B
Verified
Journal Article
Closed access
SPS. Della Penna
S. Della Penna
CDC. Delgratta
C. Delgratta
CGCarmine Granata
Carmine Granata
APA. Pasquarelli
A. Pasquarelli
VPV. Pizzella
V. Pizzella
SES. N. Erné
S. N. Erné

17 September 2012 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
Roberto RussoRoberto Russo
Roberto Russo
CGCarmine Granata
Carmine Granata
Emanuela EspositoEmanuela Esposito
Emanuela Esposito
Davide PeddisDavide Peddis
Davide Peddis
CCC. Cannas
C. Cannas
AVAntonio Vettoliere
Antonio Vettoliere
A high sensitive nano superconducting quantum interference device (nanoSQUID) operating as a magnetic flux to critical current transducer with a suitable feedback circuit is employed to measure the magnetization of ferrimagnetic iron oxide nanoparticles. An improved SQUID responsivity has been obtained by using a loop inductance asymmetry. Iron oxide nanoparticles having a mean diameter of 8 nm have been excited by applying a polarizing field in the plane of the nanoSQUID loop. The field dependence of the nanoparticle magnetization at T = 4.2 K shows magnetic hysteresis. Magnetic relaxation measurements are reported and compared with those obtained by using a commercial measurement system.

2 September 2013 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
CGCarmine Granata
Carmine Granata
AVAntonio Vettoliere
Antonio Vettoliere
Roberto RussoRoberto Russo
Roberto Russo
MFMatteo Fretto
Matteo Fretto
NLNatascia De Leo
Natascia De Leo
VLVincenzo Lacquaniti
Vincenzo Lacquaniti
We present an ultra high sensitive three-dimensional nano Superconducting QUantum Interference Device (nanoSQUID) fabricated by using the Focused Ion Beam sculpting technique. Based on a fully niobium technology, the nanodevice consists in a niobium superconducting loop (0.2 μm2) interrupted by two nanometric Nb/Al-AlOx/Nb Josephson junctions. The nanoSQUID exhibited an intrinsic magnetic flux noise as low as 0.65 μΦ0/Hz1/2 corresponding to a spin noise less than 10 Bohr magnetons per unit of bandwidth. It has been successfully employed in nanoparticle magnetic relaxation measurements. Due to its excellent performance, reliability, and robustness, we believe that the proposed nanoSQUID offers a crucial step toward a wide employment of nanoSQUIDs in the nanoscience.