The unique deformability and the compliance ability of thin sheets on soft substrates attract much interest for studying the phenomena related to elastic instabilities as well as for sensing very weak forces such as those generated by live cells in vitro. However, the techniques used currently for producing such platforms are affected by a high degree of complexity and poor repeatability. Moreover, their deformability is usually used as a passive response to the action of an external force. Herein we propose a novel concept for a reliable and dynamic skin-over-liquid system made of a periodic array of highly compliant microbumps actuated through electrode-free electrohydrodynamic (EHD) pressure. We demonstrate that these structures are highly repeatable and capable of swelling and deflating easily under a simple thermal stimulation driven by the pyroelectric effect, thus providing a challenging platform that can be actively controlled at the microscale. Furthermore, we show the proof of principle by swelling these microbumps for mechanically stimulating live cells in vitro, thus opening the route to more reliable and easy to accomplish assays in the field of mechanobiology.
This study hypothesizes that the brain shows hyper connectedness as amyotrophic lateral sclerosis (ALS) progresses. 54 patients (classified as "early stage" or "advanced stage") and 25 controls underwent magnetoencephalography and MRI recordings. The activity of the brain areas was reconstructed, and the synchronization between them was estimated in the classical frequency bands using the phase lag index. Brain topological metrics such as the leaf fraction (number of nodes with degree of 1), the degree divergence (a measure of the scale-freeness) and the degree correlation (a measure of disassortativity) were estimated. Betweenness centrality was used to estimate the centrality of the brain areas. In all frequency bands, it was evident that, the more advanced the disease, the more connected, scale-free and disassortative the brain networks. No differences were evident in specific brain areas. Such modified brain topology is sub-optimal as compared to controls. Within this framework, our study shows that brain networks become more connected according to disease staging in ALS patients.
An integrated magnetic nanosensor based on a niobium dc SQUID (superconducting quantum interference device) for nanoscale applications is presented. The sensor, having a washer shape with a hole of 200 nm and two Josephson-Dayem nanobridges of 80 nm × 100 nm, consists of a Nb(30 nm)/Al(30 nm) bilayer patterned by electron beam lithography (EBL) and shaped by lift-off and reactive ion etch (RIE) processes. The presence of the niobium coils, integrated on-chip and tightly coupled to the SQUID, allows us to easily excite the sensor in order to get the voltage-flux characteristics and to flux bias the SQUID at its optimal point. The measurements were performed at liquid helium temperature. A voltage swing of 75 µV and a maximum voltage-flux transfer coefficient (responsivity) as high as 1 mV/Φ(0) were directly measured from the voltage-flux characteristic. The noise measurements were performed in open loop mode, biasing the SQUID with a dc magnetic flux at its maximum responsivity point and using direct-coupled low-noise readout electronics. A white magnetic flux noise spectral density as low as 2.5 μΦ(0) Hz(-1/2) was achieved, corresponding to a magnetization or spin sensitivity in units of the Bohr magneton of 100 spin Hz(-1/2). Possible applications of this nanosensor can be envisaged in magnetic detection of nanoparticles and small clusters of atoms and molecules, in the measurement of nanoobject magnetization, and in quantum computing.
Heterojunction photodetector based on reduced graphene oxide (rGO) has been realized using a spin coating technique. The electrical and optical characterization of bare GO and thermally reduced GO thin films deposited on glass substrate has been carried out. Ultraviolet–visible–infrared transmittance measurements of the GO and rGO thin films revealed broad absorption range, while the absorbance analysis evaluates rGO band gap of about 2.8 eV. The effect of GO reduction process on the photoresponse capability is reported. The current–voltage characteristics and the responsivity of rGO/n-Si based device have been investigated using laser diode wavelengths from UV up to IR spectral range. An energy band diagram of the heterojunction has been proposed to explain the current versus voltage characteristics. The device demonstrates a photoresponse at a broad spectral range with a maximum responsivity and detectivity of 0.20 A/W and 7 × 1010 cmHz/W, respectively. Notably, the obtained results indicate that the rGO based device can be useful for broadband radiation detection compatible with silicon device technology.
A high sensitive nano superconducting quantum interference device (nanoSQUID) operating as a magnetic flux to critical current transducer with a suitable feedback circuit is employed to measure the magnetization of ferrimagnetic iron oxide nanoparticles. An improved SQUID responsivity has been obtained by using a loop inductance asymmetry. Iron oxide nanoparticles having a mean diameter of 8 nm have been excited by applying a polarizing field in the plane of the nanoSQUID loop. The field dependence of the nanoparticle magnetization at T = 4.2 K shows magnetic hysteresis. Magnetic relaxation measurements are reported and compared with those obtained by using a commercial measurement system.