Quantitative assessment of post-transcatheter aortic valve replacement (TAVR) aortic regurgitation (AR) remains challenging. We developed patient-specific anatomical models with pulsatile flow circuit and investigated factors associated with AR after TAVR. Based on pre-procedural computed tomography (CT) data of the six patients who underwent transfemoral TAVR using a 23-mm SAPIEN XT, anatomically and mechanically equivalent aortic valve models were developed. Forward flow and heart rate of each patient in two days after TAVR were duplicated under mean aortic pressure of 80mmHg. Paravalvular leakage (PVL) volume in basal and additional conditions was measured for each model using an electromagnetic flow sensor. Incompletely apposed tract between the transcatheter and aortic valves was examined using a micro-CT. PVL volume in each patient-specific model was consistent with each patient's PVL grade, and was affected by hemodynamic conditions. PVL and total regurgitation volume increased with the mean aortic pressure, whereas closing volume did not change. In contrast, closing volume increased proportionately with heart rate, but PVL did not change. The minimal cross-sectional gap had a positive correlation with the PVL volumes (r=0.89, P=0.02). The gap areas typically occurred in the vicinity of the bulky calcified nodules under the native commissure. PVL volume, which could be affected by hemodynamic conditions, was significantly associated with the minimal cross-sectional gap area between the aortic annulus and the stent frame. These data may improve our understanding of the mechanism of the occurrence of post-TAVR PVL.
The development of computer-aided detection (CAD) using artificial intelligence (AI) and machine learning (ML) is rapidly evolving. Submission of AI/ML-based CAD devices for regulatory approval requires information about clinical trial design and performance criteria, but the requirements vary between countries. This study compares the requirements for AI/ML-based CAD devices approved by the US Food and Drug Administration (FDA) and the Pharmaceuticals and Medical Devices Agency (PMDA) in Japan. A list of 45 FDA-approved and 12 PMDA-approved AI/ML-based CAD devices was compiled. In the USA, devices classified as computer-aided simple triage were approved based on standalone software testing, whereas devices classified as computer-aided detection/diagnosis were approved based on reader study testing. In Japan, however, there was no clear distinction between evaluation methods according to the category. In the USA, a prospective randomized controlled trial was conducted for AI/ML-based CAD devices used for the detection of colorectal polyps, whereas in Japan, such devices were approved based on standalone software testing. This study indicated that the different viewpoints of AI/ML-based CAD in the two countries influenced the selection of different evaluation methods. This study’s findings may be useful for defining a unified global development and approval standard for AI/ML-based CAD.
6 February 2021 in Cardiovascular Intervention and Therapeutics
This meta-analysis aimed to evaluate the device performance of conventional balloon catheters (POBA), drug-coated balloons (DCB), bare-metal stents (BMS), and drug-eluting stents (DES) in below-the-knee (BTK) ischemic lesions with regard to lesion characteristics. Online searches of PubMed, Web of Science, and Cochrane databases (2010–2019) were conducted for each of the test devices. Primary patency rates (pp) and major amputation rates 1 year after the use of each device were analyzed using a random-effects meta-analysis model. Meta-regression analysis was conducted to test associations between the outcomes and lesion characteristics. The analysis included 18 studies reporting on 24 separate cohorts comprising 2,438 patients. DES demonstrated the best pp among the test devices (83.6%; 95% confidence interval = 78.4–88.8%, studies = 8; I2 = 66%, P = 0.005). A negative coefficient between lesion length and pp (P = 0.002) was obtained. The ratio of critical limb ischemia (CLI) patients impacted the amputation rates (P = 0.031), whereas no statistically significant difference was found between the devices. DES showed favorable pp in BTK lesions; however, as the lesion lengths using DES were short, pp in long lesions still needs to be evaluated. Shorter lesions gained better pp. A higher ratio of CLI patients resulted in increased amputation rates.
Background The limited availability of balloon sizes for cryoballoon leads to anatomical limitations for pulmonary vein (PV) isolation. We conducted a comprehensive systematic analysis on procedural success rate, atrial fibrillation (AF) recurrence rate and complications of cryoballoon ablation in association with the anatomy of the left atrium and PV based on preprocedural CT to gain insights into proper treatments of patients with AF using cryoballoon. Method A systematic search of literature databases, including PubMed, Web of Science and Cochrane Library, from the inception of each database through February 2021 was conducted. Search keywords included ‘atrial fibrillation’, ‘cryoballoon ablation’ and ‘anatomy’. Results Overall, 243 articles were identified. After screening, 16 articles comprising 1396 patients were included (3, 5 and 8 for acute success, AF recurrence and complications, respectively). Regarding acute success and AF recurrences, thinner width of the left lateral ridge, higher PV ovality, PV ostium-bifurcation distance, shorter distance from the non-coronary cusp to inferior PVs, shallower angle of right PVs against the atrial septum and larger right superior PV (RSPV) were associated with poor outcomes. Regarding complications, shorter distance between the RSPV ostium and the right phrenic nerve, larger RSPV-left atrium angle, larger RSPV area and smaller right carina width were associated with incidences of phrenic nerve injury. Conclusion This study elucidated several key anatomical features of PVs possibly affecting acute success, AF recurrence and complications in patients with AF using cryoballoon ablation. CT analysis has helped to describe benefits and anatomical limitations for cryoballoon ablation.
14 July 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Stent struts protruding into ostial side branch called “jailed strut” at bifurcation lesions is a likely cause of thrombus formation. We aimed to investigate the influences of multiple kissing balloon inflation (KBI) for stent expansion, and stent platform design, respectively, on the reduction of incomplete stent apposition area (ISA area) caused by jailed struts at a side-branch ostium, using a three-dimensional elastic left main (LM) bifurcated coronary artery model. The referenced LM bifurcation angle data of 209 patients were stratified by tertiles focusing on the angle between the LM trunk (LMT) and left anterior descending artery (LAD). A bifurcation model was fabricated with angles of 129°, 122.2°, and 76.4° for LMT–LAD, LMT–left circumflex (LCx), and LAD–LCx, respectively, and with diameters of 5, 3.75, and 3.5 mm for LMT, LAD, and LCx, respectively; these diameters fulfill Murray’s law. A 75 % stenosis was included along the LMT. One-time and three-time KBIs were conducted using two-link Nobori and three-link Xience Xpedition (n = 6 each). The ISA area was quantified using micro-CT. Three-time KBI was effective in reducing the ISA area compared with one-time KBI for both the Nobori (p = 0.05) and Xience Xpedition (p = 0.07). The ISA area was smaller in the Nobori than in the Xience Xpedition, both in one-time and three-time KBI (one-time KBI: p = 0.003; three-time KBI: p = 0.001). Our findings of this study on reducing the ISA area by focusing on an interventional technique and stent design may help to improve coronary bifurcation intervention for a possibly better long-term clinical outcome.