Gregg Nicandri

Dr. Gregg Nicandri

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2013 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
PDF file
RKRyan J. Koehler
Ryan J. Koehler
SASimon Amsdell
Simon Amsdell
EAElizabeth A. Arendt
Elizabeth A. Arendt
LBLeslie J. Bisson
Leslie J. Bisson
JBJonathan P. Bramen
Jonathan P. Bramen
GNGregg Nicandri
Gregg Nicandri
Surgeries employing arthroscopic techniques are among the most commonly performed in orthopaedic clinical practice; however, valid and reliable methods of assessing the arthroscopic skill of orthopaedic surgeons are lacking. The Arthroscopic Surgery Skill Evaluation Tool (ASSET) will demonstrate content validity, concurrent criterion-oriented validity, and reliability when used to assess the technical ability of surgeons performing diagnostic knee arthroscopic surgery on cadaveric specimens. Cross-sectional study; Level of evidence, 3. Content validity was determined by a group of 7 experts using the Delphi method. Intra-articular performance of a right and left diagnostic knee arthroscopic procedure was recorded for 28 residents and 2 sports medicine fellowship–trained attending surgeons. Surgeon performance was assessed by 2 blinded raters using the ASSET. Concurrent criterion-oriented validity, interrater reliability, and test-retest reliability were evaluated. Content validity: The content development group identified 8 arthroscopic skill domains to evaluate using the ASSET. Concurrent criterion-oriented validity: Significant differences in the total ASSET score (P < .05) between novice, intermediate, and advanced experience groups were identified. Interrater reliability: The ASSET scores assigned by each rater were strongly correlated (r = 0.91, P < .01), and the intraclass correlation coefficient between raters for the total ASSET score was 0.90. Test-retest reliability: There was a significant correlation between ASSET scores for both procedures attempted by each surgeon (r = 0.79, P < .01). The ASSET appears to be a useful, valid, and reliable method for assessing surgeon performance of diagnostic knee arthroscopic surgery in cadaveric specimens. Studies are ongoing to determine its generalizability to other procedures as well as to the live operating room and other simulated environments.

6 February 2013 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
PDF file
ABAaron Butler
Aaron Butler
TOTyson Olson
Tyson Olson
RKRyan Koehler
Ryan Koehler
GNGregg Nicandri
Gregg Nicandri
Background: The use of surgical simulation in orthopaedic education is increasing; however, its ideal place within the training curriculum remains unknown. The purpose of this study was to determine the effectiveness of training novice surgeons on an anatomic dry model of the knee prior to training them to perform diagnostic arthroscopy on cadaveric specimens. Methods: Fourteen medical students were randomly assigned to two groups. The experimental group was trained to perform diagnostic arthroscopy of the knee on anatomic dry models prior to training on cadaveric specimens. The control group was trained only on cadaveric specimens. Proficiency was assessed with use of a modified version of a previously validated objective assessment of arthroscopic skill, the Basic Arthroscopic Knee Skill Scoring System (BAKSSS). The mean number of trials required to attain minimal proficiency when performing diagnostic knee arthroscopy was compared between the groups. The cumulative transfer effectiveness ratio (CTER) was calculated to measure the transfer of skills acquired by the experimental group. Results: The mean number of trials to demonstrate minimum proficiency was significantly lower in the experimental group (2.57) than in the control group (4.57) (p < 0.01). The mean time to demonstrate proficiency was also significantly less in the experimental group (37.51 minutes) than in the control group (60.48 minutes) (p < 0.01). The CTER of dry-model training for the task of performing diagnostic knee arthroscopy on cadaveric specimens was 0.2. Conclusions: Previous training utilizing an anatomic dry knee model resulted in improved proficiency for novice surgeons learning to perform diagnostic knee arthroscopy on cadaveric specimens. A CTER of 0.2 suggests that dry models can serve as a useful adjunct to cadaveric training for diagnostic knee arthroscopy but cannot entirely replace it within the orthopaedic curriculum. Further work is necessary to determine the optimal amount of training on anatomic dry models that will maximize transfer effectiveness and to determine how well skills obtained in the simulated environment transfer to the operating room.

25 September 2009 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
GNGregg Nicandri
Gregg Nicandri
RDRobert P. Dunbar
Robert P. Dunbar
CWChristopher J. Wahl
Christopher J. Wahl

1 December 2013 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
RKRyan J. Koehler
Ryan J. Koehler
GNGregg Nicandri
Gregg Nicandri
Xperts. The purpose of this study was to test the validity and reliability of the Arthroscopic Surgery Skill Evaluation Tool as a pass-fail examination of arthroscopic skill. Methods: Twenty-eight residents and two sports medicine faculty members were recorded performing diagnostic knee arthroscopy on a left and right cadaveric specimen in our arthroscopic skills laboratory. Procedure videos were evaluated with use of the Arthroscopic Surgery Skill Evaluation Tool by two raters blind to subject identity. Subjects were considered to pass the Arthroscopic Surgery Skill Evaluation Tool when they attained scores of ≥3 on all eight assessment domains. Results: The raters agreed on a pass-fail rating for fifty-five of sixty videos rated with an interclass correlation coefficient value of 0.83. Ten of thirty participants were assigned passing scores by both raters for both diagnostic arthroscopies performed in the laboratory. Receiver operating characteristic analysis demonstrated that logging more than eighty arthroscopic cases or performing more than thirty-five arthroscopic knee cases was predictive of attaining a passing Arthroscopic Surgery Skill Evaluation Tool score on both procedures performed in the laboratory. Conclusions: The Arthroscopic Surgery Skill Evaluation Tool is valid and reliable as a pass-fail examination of diagnostic arthroscopy of the knee in the simulation laboratory. Clinical Relevance: This study demonstrates that the Arthroscopic Surgery Skill Evaluation Tool may be a useful tool for pass-fail examination of diagnostic arthroscopy of the knee in the simulation laboratory. Further study is necessary to determine whether the Arthroscopic Surgery Skill Evaluation Tool can be used for the assessment of multiple arthroscopic procedures and whether it can be used to evaluate arthroscopic procedures performed in the operating room....

8 November 2021 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
TMThomas G. Myers
Thomas G. Myers
JMJ. Lawrence Marsh
J. Lawrence Marsh
GNGregg Nicandri
Gregg Nicandri
JGJohn Gorczyca
John Gorczyca
VPVincent D. Pellegrini
Vincent D. Pellegrini
➤ Orthopaedic education should produce surgeons who are competent to function independently and can obtain and maintain board certification. ➤ Contemporary orthopaedic training programs exist within a fixed 5-year time frame, which may not be a perfect match for each trainee. ➤ Most modern orthopaedic residencies have not yet fully adopted objective, proficiency-based, surgical skill training methods despite nearly 2 decades of evidence supporting the use of this methodology. ➤ Competency-based medical education backed by surgical simulation rooted in proficiency-based progression has the potential to address surgical skill acquisition challenges in orthopaedic surgery.

1 May 2013
Verified
Journal Article
Closed access
PDF file
TOTyson Olson
Tyson Olson
RKRyan Koehler
Ryan Koehler
ABAaron Butler
Aaron Butler
SASimon Amsdell
Simon Amsdell
GNGregg Nicandri
Gregg Nicandri
The Basic Arthroscopic Knee Skill Scoring System (BAKSSS) has construct validity as an objective measure of arthroscopic proficiency when used to assess the task of performing arthroscopic meniscectomies on cadaver knees. The reliability of this instrument is unknown. We asked whether (1) a simple modification of the BAKSSS would show construct validity similar to that in the initial BAKSSS study, (2) this assessment would be reliable, and (3) this assessment could be used as a high-stakes pass or fail test. Twenty-three orthopaedic residents performed diagnostic knee arthroscopies on cadaveric knee specimens. Their competency was assessed by three live raters using the modified BAKSSS. Interrater reliability was assessed by comparing the scores given by each rater to each subject. The modified BAKSSS showed construct validity with junior residents achieving lower scores (mean score, 20) than senior residents (mean score, 33). The modified BAKSSS had an interrater reliability of kappa = 0.685-0.852. The modified BAKSSS had a kappa = 0.543 when used as a proficiency test for diagnostic arthroscopy. The modified BAKSSS is useful for assessing diagnostic knee arthroscopy proficiency. Future scoring systems should be designed to be generalizable so they can be applied to multiple procedures without the need for modification, allow for video-based assessment, and must be rigorously tested for reliability and other types of validity (eg, face validity, content validity, and criterion-related validity). Having a valid and reliable assessment of basic arthroscopic procedures may allow educators to more adequately evaluate individual residents and the effectiveness of various training modalities.