Gaston A. Crespo

Dr. Gaston A. Crespo

Assistant Professor, Applied Physical Chemistry, KTH Royal Institute of Technology, SE 100 44 Stockholm, Sweden
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Open access
Marc Parrilla PonsMarc Parrilla Pons
Marc Parrilla Pons
MCMaría Cuartero
María Cuartero
Gaston A. CrespoGaston A. Crespo
Gaston A. Crespo

6 July 2021 in ACS Sensors
Verified
Journal Article
Open access
Xing XuanXing Xuan
Xing Xuan
CPClara Pérez-Ràfols
Clara Pérez-Ràfols
CCChen Chen
Chen Chen
MCMaria Cuartero
Maria Cuartero
Gaston A. CrespoGaston A. Crespo
Gaston A. Crespo
Wearable lactate sensors for sweat analysis are highly appealing for both the sports and healthcare fields. Electrochemical biosensing is the approach most widely used for lactate determination, and this technology generally demonstrates a linear range of response far below the expected lactate levels in sweat together with a high influence of pH and temperature. In this work, we present a novel analytical strategy based on the restriction of the lactate flux that reaches the enzyme lactate oxidase, which is immobilized in the biosensor core. This is accomplished by means of an outer plasticized polymeric layer containing the quaternary salt tetradodecylammonium tetrakis(4-chlorophenyl) borate (traditionally known as ETH500). Also, this layer prevents the enzyme from being in direct contact with the sample, and hence, any influence with the pH and temperature is dramatically reduced. An expanded limit of detection in the millimolar range (from 1 to 50 mM) is demonstrated with this new biosensor, in addition to an acceptable response time; appropriate repeatability, reproducibility, and reversibility (variations lower than 5% for the sensitivity); good resiliency; excellent selectivity; low drift; negligible influence of the flow rate; and extraordinary correlation (Pearson coefficient of 0.97) with a standardized method for lactate detection such as ion chromatography (through analysis of 22 sweat samples collected from 6 different subjects performing cycling or running). The developed lactate biosensor is suitable for on-body sweat lactate monitoring via a microfluidic epidermal patch additionally containing pH and temperature sensors. This applicability was demonstrated in three different body locations (forehead, thigh, and back) in a total of five on-body tests while cycling, achieving appropriate performance and validation. Moreover, the epidermal patch for lactate sensing is convenient for the analysis of sweat stimulated by iontophoresis in the subjects’ arm, which is of great potential toward healthcare applications.

18 December 2008 in Analytical Chemistry
Verified
Journal Article
Closed access
Gaston A. CrespoGaston A. Crespo
Gaston A. Crespo
SMSantiago Macho
Santiago Macho
Johan BobackaJohan Bobacka
Johan Bobacka
FRF. Xavier Rius
F. Xavier Rius

26 June 2020 in Analytical Chemistry
Verified
Journal Article
Open access
AWAlexander Wiorek
Alexander Wiorek
Marc Parrilla PonsMarc Parrilla Pons
Marc Parrilla Pons
MCMaría Cuartero
María Cuartero
Gaston A. CrespoGaston A. Crespo
Gaston A. Crespo
We present an epidermal patch for glucose analysis in sweat incorporating for the first time pH and temperature correction according to local dynamic fluctuations in sweat during on-body tests. This sort of correction is indeed the main novelty of the paper, being crucial toward reliable measurements in every sensor based on an enzymatic element whose activity strongly depends on pH and temperature. The results herein reported for corrected glucose detection during on-body measurements are supported by a two-step validation protocol: with the biosensor operating off- and on-bodily, correlating the results with UV–vis spectrometry and/or ion chromatography. Importantly, the wearable device is a flexible skin patch that comprises a microfluidic cell designed with a sweat collection zone coupled to a fluidic channel in where the needed electrodes are placed: glucose biosensor, pH potentiometric electrode and a temperature sensor. The glucose biosensor presents a linear range of response within the expected physiological levels of glucose in sweat (10–200 μM), and the calibration parameters are dynamically adjusted to any change in pH and temperature during the sport practice by means of a new “correction approach”. In addition, the sensor displays a fast response time, appropriate selectivity, and excellent reversibility. A total of 9 validated on-body tests are presented: the outcomes revealed a great potential of the wearable glucose sensor toward the provision of reliable physiological data linked to individuals during sport activity. In particular, the developed “correction approach” is expected to impact into the next generation of wearable devices that digitalize physiological activities through chemical information in a trustable manner for both sport and healthcare applications.

2 February 2014 in Nature Chemistry
Verified
Journal Article
Closed access
XXXiaojiang Xie
Xiaojiang Xie
Gaston A. CrespoGaston A. Crespo
Gaston A. Crespo
GMGünter Mistlberger
Günter Mistlberger
EBEric Bakker
Eric Bakker

13 December 2018 in Analytical Chemistry
Verified
Journal Article
Open access
Marc Parrilla PonsMarc Parrilla Pons
Marc Parrilla Pons
MCMaría Cuartero
María Cuartero
SSSara Padrell Sánchez
Sara Padrell Sánchez
MRMina Rajabi
Mina Rajabi
NRNiclas Roxhed
Niclas Roxhed
Gaston A. CrespoGaston A. Crespo
Gaston A. Crespo
A new analytical all-solid-state platform for intradermal potentiometric detection of potassium in interstitial fluid is presented here. Solid microneedles are modified with different coatings and polymeric membranes to prepare both the potassium-selective electrode and reference electrode needed for the potentiometric readout. These microneedle-based electrodes are then fixed in an epidermal patch suitable for insertion into the skin. The analytical performances observed for the potentiometric cell (Nernstian slope, limit of detection of 10-4.9 potassium activity, linear range of 10-4.2 to 10-1.1, drift of 0.35 ± 0.28 mV h-1), together with a fast response time, adequate selectivity and excellent reproducibility and repeatability, are appropriate for potassium analysis in interstitial fluid within both clinical and harmful levels. The potentiometric response is maintained after several insertions into animal skin, confirming the resiliency of the microneedle-based sensor. Ex vivo tests based on the intradermal detection of potassium in chicken and porcine skin demonstrate that the microneedle patch is suitable for monitoring potassium changes inside the skin. In addition, the dimensions of the microneedles modified with the corresponding layers necessary to enhance robustness and provide sensing capabilities (1000 µm length, 45° tip angle, 15 µm thickness in the tip and 435 µm in the base) agree with the required ranges for a painless insertion into the skin. In vitro cytotoxicity experiments showed that the patch can be used for at least 24 h without any side effect for the skin cells. Overall, the developed concept constitutes important progress in the intradermal analysis of ions related to an electrolyte imbalance in humans, which is relevant for the control of certain types of diseases.