María Cuartero

Mrs. María Cuartero


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Open access
Marc Parrilla PonsMarc Parrilla Pons
Marc Parrilla Pons
MCMaría Cuartero
María Cuartero
Gaston A. CrespoGaston A. Crespo
Gaston A. Crespo

26 June 2020 in Analytical Chemistry
Verified
Journal Article
Open access
AWAlexander Wiorek
Alexander Wiorek
Marc Parrilla PonsMarc Parrilla Pons
Marc Parrilla Pons
MCMaría Cuartero
María Cuartero
Gaston A. CrespoGaston A. Crespo
Gaston A. Crespo
We present an epidermal patch for glucose analysis in sweat incorporating for the first time pH and temperature correction according to local dynamic fluctuations in sweat during on-body tests. This sort of correction is indeed the main novelty of the paper, being crucial toward reliable measurements in every sensor based on an enzymatic element whose activity strongly depends on pH and temperature. The results herein reported for corrected glucose detection during on-body measurements are supported by a two-step validation protocol: with the biosensor operating off- and on-bodily, correlating the results with UV–vis spectrometry and/or ion chromatography. Importantly, the wearable device is a flexible skin patch that comprises a microfluidic cell designed with a sweat collection zone coupled to a fluidic channel in where the needed electrodes are placed: glucose biosensor, pH potentiometric electrode and a temperature sensor. The glucose biosensor presents a linear range of response within the expected physiological levels of glucose in sweat (10–200 μM), and the calibration parameters are dynamically adjusted to any change in pH and temperature during the sport practice by means of a new “correction approach”. In addition, the sensor displays a fast response time, appropriate selectivity, and excellent reversibility. A total of 9 validated on-body tests are presented: the outcomes revealed a great potential of the wearable glucose sensor toward the provision of reliable physiological data linked to individuals during sport activity. In particular, the developed “correction approach” is expected to impact into the next generation of wearable devices that digitalize physiological activities through chemical information in a trustable manner for both sport and healthcare applications.

13 December 2018 in Analytical Chemistry
Verified
Journal Article
Open access
Marc Parrilla PonsMarc Parrilla Pons
Marc Parrilla Pons
MCMaría Cuartero
María Cuartero
SSSara Padrell Sánchez
Sara Padrell Sánchez
MRMina Rajabi
Mina Rajabi
NRNiclas Roxhed
Niclas Roxhed
Gaston A. CrespoGaston A. Crespo
Gaston A. Crespo
A new analytical all-solid-state platform for intradermal potentiometric detection of potassium in interstitial fluid is presented here. Solid microneedles are modified with different coatings and polymeric membranes to prepare both the potassium-selective electrode and reference electrode needed for the potentiometric readout. These microneedle-based electrodes are then fixed in an epidermal patch suitable for insertion into the skin. The analytical performances observed for the potentiometric cell (Nernstian slope, limit of detection of 10-4.9 potassium activity, linear range of 10-4.2 to 10-1.1, drift of 0.35 ± 0.28 mV h-1), together with a fast response time, adequate selectivity and excellent reproducibility and repeatability, are appropriate for potassium analysis in interstitial fluid within both clinical and harmful levels. The potentiometric response is maintained after several insertions into animal skin, confirming the resiliency of the microneedle-based sensor. Ex vivo tests based on the intradermal detection of potassium in chicken and porcine skin demonstrate that the microneedle patch is suitable for monitoring potassium changes inside the skin. In addition, the dimensions of the microneedles modified with the corresponding layers necessary to enhance robustness and provide sensing capabilities (1000 µm length, 45° tip angle, 15 µm thickness in the tip and 435 µm in the base) agree with the required ranges for a painless insertion into the skin. In vitro cytotoxicity experiments showed that the patch can be used for at least 24 h without any side effect for the skin cells. Overall, the developed concept constitutes important progress in the intradermal analysis of ions related to an electrolyte imbalance in humans, which is relevant for the control of certain types of diseases.

16 October 2019 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
PDF file
QMQijun Meng
Qijun Meng
BZBiaobiao Zhang
Biaobiao Zhang
LFLizhou Fan
Lizhou Fan
Haidong LiuHaidong Liu
Haidong Liu
MVMario Valvo
Mario Valvo
LSLicheng Sun
Licheng Sun
Water‐splitting photoanodes based on semiconductor materials typically require a dopant in the structure and co‐catalysts on the surface to overcome the problems of charge recombination and high catalytic barrier. Unlike these conventional strategies, a simple treatment is reported that involves soaking a sample of pristine BiVO4 in a borate buffer solution. This modifies the catalytic local environment of BiVO4 by the introduction of a borate moiety at the molecular level. The self‐anchored borate plays the role of a passivator in reducing the surface charge recombination as well as that of a ligand in modifying the catalytic site to facilitate faster water oxidation. The modified BiVO4 photoanode, without typical doping or catalyst modification, achieved a photocurrent density of 3.5 mA cm−2 at 1.23 V and a cathodically shifted onset potential of 250 mV. This work provides an extremely simple method to improve the intrinsic photoelectrochemical performance of BiVO4 photoanodes.

3 June 2019 in Analytical Chemistry
Verified
Journal Article
Open access
Marc Parrilla PonsMarc Parrilla Pons
Marc Parrilla Pons
IOInmaculada Ortiz-Gómez
Inmaculada Ortiz-Gómez
Rocio CanovasRocio Canovas
Rocio Canovas
ASAlfonso Salinas-Castillo
Alfonso Salinas-Castillo
MCMaría Cuartero
María Cuartero
Gaston A. CrespoGaston A. Crespo
Gaston A. Crespo
Herein, the reproducibility and a double validation of on-body measurements provided by new wearable potentiometric ion sensors (WPISs) is presented. Sweat collected during sport practice was first analyzed using the developed device, the pH-meter and ion chromatography (IC) prior to on-body measurements (off-site validation). Subsequently, the accuracy of on-body measurements accomplished by the WPISs was evaluated by comparison with pH-meter readings and IC after collecting sweat (every 10-12.5 min) during sport practice. The developed device contains sensors for pH, Cl–, K+ and Na+ that are embedded in a flexible sampling cell for sweat analysis. The electrode array was fabricated employing MWCNTs (as ion-to-electron transducer) and stretchable materials that has been exhaustively characterized in terms of analytical performance, presenting Nernstian slopes within the expected physiological range of each ion analyte (Cl–: 10 – 100 mM, K+: 10 – 10 mM, Na+: 10 – 100 mM; and pH: 4.5 – 7.5), drift suitable for mid-term exercise practice (0.3±0.2 mV h-1), fast response time, adequate selectivity for sweat measurements and excellent reversibility. Besides that, the designed sampling cell avoids any sweat contamination and evaporation issues while supplying a passive sweat flow encompassing specifically the individual’s perspiration. The interpretation of ion concentration profiles may permit the identification of personal dynamic patterns in sweat composition while practicing sport.

14 August 2015 in Analytical Chemistry
Verified
Journal Article
Closed access
DYDajing Yuan
Dajing Yuan
AAAlexandre H. C. Anthis
Alexandre H. C. Anthis
MAMajid Amin Afshar
Majid Amin Afshar
NPNadezda Pankratova
Nadezda Pankratova
MCMaría Cuartero
María Cuartero
EBEric Bakker
Eric Bakker