Sarvenaz Keshmiri

Ms. Sarvenaz Keshmiri

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2023 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
FFFrancesca di Franco
Francesca di Franco
NRNicolas Rosuel
Nicolas Rosuel
LGLaurent Gallin-Martel
Laurent Gallin-Martel
MGMarie-Laure Gallin-Martel
Marie-Laure Gallin-Martel
MGMostafa Ghafooryan-Sangchooli
Mostafa Ghafooryan-Sangchooli
JAJean-François Adam
Jean-François Adam
Microbeam radiation therapy (MRT) is a radiotherapy technique combining spatial fractionation of the dose distribution on a micrometric scale, X-rays in the 50–500 keV range and dose rates up to 16 × 103 Gy s−1. Nowadays, in vivo dosimetry remains a challenge due to the ultra-high radiation fluxes involved and the need for high-spatial-resolution detectors. The aim here was to develop a striped diamond portal detector enabling online microbeam monitoring during synchrotron MRT treatments. The detector, a 550 µm bulk monocrystalline diamond, is an eight-strip device, of height 3 mm, width 178 µm and with 60 µm spaced strips, surrounded by a guard ring. An eight-channel ASIC circuit for charge integration and digitization has been designed and tested. Characterization tests were performed at the ID17 biomedical beamline of the European Synchrotron Radiation Facility (ESRF). The detector measured direct and attenuated microbeams as well as interbeam fluxes with a precision level of 1%. Tests on phantoms (RW3 and anthropomorphic head phantoms) were performed and compared with simulations. Synchrotron radiation measurements were performed on an RW3 phantom for strips facing a microbeam and for strips facing an interbeam area. A 2% difference between experiments and simulations was found. In more complex geometries, a preliminary study showed that the absolute differences between simulated and recorded transmitted beams were within 2%. Obtained results showed the feasibility of performing MRT portal monitoring using a microstriped diamond detector. Online dosimetric measurements are currently ongoing during clinical veterinary trials at ESRF, and the next 153-strip detector prototype, covering the entire irradiation field, is being finalized at our institution.

29 July 2024 in Cancers
Verified
Journal Article
Open access
PDF file
LELaura Eling
Laura Eling
SKSamy Kefs
Samy Kefs
Sarvenaz KeshmiriSarvenaz Keshmiri
Sarvenaz Keshmiri
JBJacques Balosso
Jacques Balosso
SCSusan Calvet
Susan Calvet
RSRaphael Serduc
Raphael Serduc
Synchrotron Microbeam Radiation Therapy (MRT) has repeatedly proven its superiority compared with conventional radiotherapy for glioma control in preclinical research. The clinical transfer phase of MRT has recently gained momentum; seven dogs with suspected glioma were treated under clinical conditions to determine the feasibility and safety of MRT. We administered a single fraction of 3D-conformal, image-guided MRT. Ultra-high-dose rate synchrotron X-ray microbeams (50 µm-wide, 400 µm-spaced) were delivered through five conformal irradiation ports. The PTV received ~25 Gy peak dose (within microbeams) per port, corresponding to a minimal cumulated valley dose (diffusing between microbeams) of 2.8 Gy. The dogs underwent clinical and MRI follow-up, and owner evaluations. One dog was lost to follow-up. Clinical exams of the remaining six dogs during the first 3 months did not indicate radiotoxicity induced by MRT. Quality of life improved from 7.3/10 [±0.7] to 8.9/10 [±0.3]. Tumor-induced seizure activity decreased significantly. A significant tumor volume reduction of 69% [±6%] was reached 3 months after MRT. Our study is the first neuro-oncologic veterinary trial of 3D-conformal Synchrotron MRT and reveals that MRT does not induce acute to subacute radiotoxicity in normal brain tissues. MRT improves quality of life and leads to remarkable tumor volume reduction despite low valley dose delivery. This trial is an essential step towards the forthcoming clinical application of MRT against deep-seated human brain tumors.

28 February 2024 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
Sarvenaz KeshmiriSarvenaz Keshmiri
Sarvenaz Keshmiri
GLGaëtan Lemaire
Gaëtan Lemaire
SBSylvan Brocard
Sylvan Brocard
CVCamille Verry
Camille Verry
YBYacine Bencheikh
Yacine Bencheikh
JAJean-François Adam
Jean-François Adam
Background and Purpose: Microbeam Radiation Therapy (MRT) aims to deliver higher doses to the target while minimizing radiation damage to healthy tissues using synchrotron x-ray microbeams. Translational MRT research has now started, driven by promising results from preclinical studies. This study aimed to propose a first dose-outcome model by analyzing micrometric dose distributions obtained with high-resolution 3D dose calculations, accounting for the inherent physical dose distribution complexity in MRT. The feasibility of integrating penMRT, our full Monte Carlo multiscale dose calculation algorithm based on PENELOPE into translational research on veterinary patients was also investigated. Material and Methods: Micrometric dose distributions were calculated in tumor-bearing rats and for a veterinary patient with penMRT, for conformal multi-directional MRT treatment plans. Absorbed dose maps were obtained with 0.005 x 0.005 x 1 mm3 voxel sizes. High-resolution dose-volume histograms were extracted and analyzed against radiobiology studies. Results: The complexity of the MRT dose distribution was properly rendered at a micrometer scale on 3D dose maps, with well separated dose regions observed on the differential dose-volume histograms. The median survival time of glioma-bearing rats varied linearly with the volume fraction of the planning target volume that received doses higher than 50 Gy (R2 = 0.98). The feasibility of using penMRT for treatment planning in large volumes has been shown on a veterinary patient. Conclusions: This study demonstrated the significant added value of penMRT for planning and prescribing MRT treatments. It also shed light on the correlation between the high-resolution 3D dose distributions and the treatment outcome.

23 December 2025 in Epilepsia
Verified
Journal Article
Open access
LSLoan Samalens
Loan Samalens
CBCamille Beets
Camille Beets
CCClothilde Courivaud
Clothilde Courivaud
Sarvenaz KeshmiriSarvenaz Keshmiri
Sarvenaz Keshmiri
JAJean‐François Adam
Jean‐François Adam
ADAntoine Depaulis
Antoine Depaulis
Objective: One‐third of patients with epilepsy, particularly those with mesial temporal lobe epilepsy (MTLE), remain resistant to medication. Resective surgery, the gold standard, is highly invasive and carries significant risks. Here, using a mouse model, we explored the potential of microbeam radiation therapy (MRT), a new technique based on the spatial microfractionation of high‐flux X‐rays, as a non‐invasive alternative for treating MTLE. Methods: MTLE was modeled in male C57BL6/J mice via unilateral kainate injection in the dorsal hippocampus. Mice with magnetic resonance imaging (MRI)–validated hippocampal sclerosis (HS) were irradiated at the European Synchrotron Radiation Facility (ESRF) using MRT with either a single trajectory (peak doses = 125–500 Gy) or multiple trajectories (2 or 5 ports at a cumulated peak dose of 125 Gy at the target). Their focal seizures were then monitored with use of electroencephalography (EEG) during 8 weeks, upon which immunochemistry was performed to assess potential tissular toxicity. Results: Anteroposterior 1‐port MRT significantly reduced EEG‐recorded focal seizures at 125 and 250 Gy, in a dose‐dependent manner. However, increased mortality was observed at 500 Gy. Immunohistolabeling revealed neuronal loss (revealed by NeuN staining), microgliosis (revealed by Iba1 straining), and astrogliosis (revealed by GFAP staining) limited to the microbeam tracks at all doses in the injected hippocampus and adjacent brain structures (e.g., cortex). Five‐port MRT with a peak dose of 125 Gy at the target improved the antiepileptic effect, whereas no significant tissue alterations outside the microbeam tracks were detected by histological assessment. Significance: This proof‐of‐concept study highlights MRT as a promising non‐invasive therapy for drug‐resistant focal epilepsies with optimal peak doses of 125–250 Gy, and it suggests that distributing the dose through multiple angles optimizes the therapeutic effect. MRT could provide a safer alternative to surgery, warranting further investigations.