Lijun Yang

Dr. Lijun Yang


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2020 in Molecules
Verified
Journal Article
Open access
PDF file
CLChen LI
Chen LI
YYYong Yang
Yong Yang
LYLijun Yang
Lijun Yang
ZSZhen Shi
Zhen Shi
PYPengfei Yang
Pengfei Yang
GCGuanghua Cheng
Guanghua Cheng
The bioactivity and biocompatibility play key roles in the success of dental and orthopaedic implants. Although most commercial implant systems use various surface microstructures, the ideal multi-scale topographies capable of controlling osteointegration have not yielded conclusive results. Inspired by both the isotropic adhesion of the skin structures in tree frog toe pads and the anisotropic adhesion of the corrugated ridges on the scales of Morpho butterfly wings, composite micro/nano-structures, including the array of micro-hexagons and oriented nano-ripples on titanium alloy implants, were respectively fabricated by microsecond laser direct writing and femtosecond laser-induced periodic surface structures, to improve cell adherence, alignment and proliferation on implants. The main differences in both the bioactivity in simulated body fluid and the biocompatibility in osteoblastic cell MC3T3 proliferation were measured and analyzed among Ti-6Al-4V samples with smooth surface, micro-hexagons and composite micro/nano-structures, respectively. Of note, bioinspired micro/nano-structures displayed the best bioactivity and biocompatibility after in vitro experiments, and meanwhile, the nano-ripples were able to induce cellular alignment within the micro-hexagons. The reasons for these differences were found in the topographical cues. An innovative functionalization strategy of controlling the osteointegration on titanium alloy implants is proposed using the composite micro/nano-structures, which is meaningful in various regenerative medicine applications and implant fields.

26 November 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
CLChen LI
Chen LI
YYYong Yang
Yong Yang
LYLijun Yang
Lijun Yang
ZSZhen Shi
Zhen Shi
The electrosurgical blade is the most common invasive surgical instrument in a cutting and hemostasis process; however, the blade easily leads to the adhesion of overheated soft tissues on the blades and induces a potential danger for the patients. To minimize the adhesive tissues, we proposed the one-step surface texturing method to fabricate anti-adhesive biomimetic scales on stainless steel 316L rapidly based on the self-organized surface microstructures induced by the long-pulse fiber laser, which was inspired by the excellent performances of anti-adhesion and anti-friction in the pangolin scales. The optimal formation parameters, chemical components, and crystal structures of the laser-induced self-organized surface microstructures were investigated in the experiments. Moreover, the underlying formation mechanism was revealed. The electrosurgical blades with biomimetic scales have hydrophobicity and a smaller frictional coefficient, which effectively reduced the adhesion of soft tissue.

15 August 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
CLChen LI
Chen LI
CZchi zhang
chi zhang
LYLijun Yang
Lijun Yang
FGFangtong Guo
Fangtong Guo
At present, there are few methods to measure optical pressure using MEMS. However, due to its high precision and fast response, a ridge waveguide pressure sensor based on a Mach–Zehnder interferometer is designed in this paper. Through the design and optimization of each component of the structure, the sensitivity of the pressure sensor was 2.2 × 10−3 W/kPa and the linearity was 5.9 × 10−3. The sensor had a good performance and small volume, which can be used in the field of light pressure measurement and other fields that required the measurement small pressures, such as the biomedicine field.

5 August 2025 in ACS Omega
Verified
Journal Article
Open access
PHPeiying Han
Peiying Han
LYLijun Yang
Lijun Yang
ZZZhaofei Zhu
Zhaofei Zhu
XLXuyuan Liang
Xuyuan Liang
WWWanxin Wu
Wanxin Wu
The coffee-ring effect commonly occurs during the evaporation and deposition of particle-laden droplets on the substrates. The resulting deposition pattern is influenced by internal flows, which depend on substrate properties, droplet chemistry, and external conditions. However, in applications such as inkjet printing, drug formulation, and self-assembly, avoiding coffee ring formation is crucial. This study presents a method to suppress the coffee-ring effect using focused laser irradiation on droplet surfaces. By irradiating droplets containing silica microparticles with a green laser and adjusting the particle concentration, we controlled the deposition patterns. Uniform patterns formed at particle concentrations below 0.02%, while gradient patterns appeared above 0.08%. A dimensionless parameter, G, was introduced to quantify particle deposition patterns. Uniform deposition structures are established when G max > 10, whereas gradient structures are formed when G max < 2. This approach offers new insights into the laser-induced control of microparticle deposition patterns.

10 March 2025 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Open access
PDF file
LYLijun Yang
Lijun Yang
XLXuyuan Liang
Xuyuan Liang
MLMingxuan Liu
Mingxuan Liu
Objectives: This study focuses on the effect of microstructural surface characteristics on metal-ceramic bond strength for SLM-fabricated titanium alloy. This research seeks to improve metal-ceramic adhesion in SLM-produced parts. Methods: Inspired by the hydrophilic structure of Calathea zebrina, bioinspired microstructures were designed on titanium alloy surfaces. Samples were categorized into two groups: those with microstructured surfaces and those with smooth surfaces. Various microstructural parameters were implemented. Bending tests were conducted on all samples, which were subjected to the same porcelain-fused-to-metal sintering process. Scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) were employed to examine the bonding and separation surfaces of titanium alloy and porcelain. Results: Metal-porcelain bonding strength is strongly influenced by the spacing and height of the bionic microstructure. Surfaces with the microstructure showed significantly higher bonding strength and distinctly different residue characteristics after peeling compared to surfaces without the microstructure. Conclusions: Microstructured surfaces on titanium alloy substrates facilitate robust chemical and mechanical bonding between metal and porcelain, markedly enhancing the performance of SLM-produced metal-ceramic restorations.