Robert Riedlmajer

Dr. Robert Riedlmajer

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 September 2022 in Materials
Verified
Journal Article
Open access
PDF file
PNPavol Noga
Pavol Noga
ZSZoltán Száraz
Zoltán Száraz
MKMatej Kubiš
Matej Kubiš
JDJozef Dobrovodský
Jozef Dobrovodský
FFFilip Ferenčík
Filip Ferenčík
Vladimir KrsjakVladimir Krsjak
Vladimir Krsjak
Structural materials of the new generation of nuclear reactors, fission as well as fusion, must often cope with high production rates of transmutation helium. Their testing hence requires either a powerful source of fast neutrons or a high-fluence ion-irradiation facility providing sufficient amounts of high-energy helium to investigate its effect on the material. Most ion irradiation studies, however, concentrate on basic effects such as defect evolution or bubble swelling in narrow near-surface regions modified by ion bombardment. Studies on bulk samples with a relatively thick implanted region, which would enable, for instance, micromechanical testing, are underrepresented. This gap might be filled by high-fluence multi-energy ion irradiations modifying several tens of micrometres of the investigated substrate. High-energy ion accelerators providing reasonable currents with energies of tens of MeV are rarely employed in such studies due to their scarcity or considerable beamtime costs. To contribute to this field, this article reports a unique single-beam He implantation experiment aimed at obtaining quasi-uniform displacement damage across >60 μm with the He/dpa ratio roughly one order of magnitude above the typical spallation neutron target irradiation conditions. Some technical aspects of this irradiation experiment, along with recent developments and upgrades at the 6 MV Tandetron accelerator of the Slovak university of technology in Bratislava, are presented.

23 April 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSMaximilián Strémy
Maximilián Strémy
DHDusan Horvath
Dusan Horvath
DVDusan Vana
Dusan Vana
MKMichal Kebisek
Michal Kebisek
Gabriel GasparGabriel Gaspar
Gabriel Gaspar
RRRobert Riedlmajer
Robert Riedlmajer
Rutherford backscattering spectrometry (RBS) in channeling regimes (RBS/C), as an ion beam analysis method performed on a Tandetron 6MV accelerator, generally gives precise information about the structure of crystalline samples by combining RBS signals in the random and aligned configurations. This paper presents details about the design and implementation of tailored RBS/C measurements (coarse and fine) and data evaluation application developed in MATLAB for in situ accelerator control system ARGUS, delivered by High Voltage Engineering Europa BV (HVEE). Additionally, we examined two different ways of stepping during the measurement to reduce the possible inaccuracies related with goniometer’s backslash affecting the evaluation of spectra. Verification experiment was carried out using a 2-MeV 4He+-beam directed on a Si (100) substrate. The channeling effect is seen as channeling dips of a lower signal in an otherwise rather homogeneous plane. Implemented application significantly facilitates the RBS/C measurement and analysis of the experiments, and also extends the ion beam analysis portfolio of Advanced Technologies Research Institute. Finally, software is ready-to-use for any Tandetron based ion beam facility with the ARGUS software for accelerator control.

1 September 2018 in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
Verified
Journal Article
Open access
PDF file
MBMatúš Beňo
Matúš Beňo
JDJozef Dobrovodský
Jozef Dobrovodský
DVDušan Vaňa
Dušan Vaňa
SMStanislav Minarik
Stanislav Minarik
RRRobert Riedlmajer
Robert Riedlmajer
The trace element analysis system is presented using Proton Induced X-ray Emission (PIXE) analysis at a new Ion Beam Centre in Trnava. Standard PIXE system dedicated to the measurement of thick solid samples was extended by a new application for trace element analysis in aerosol samples. The sample holder was modified with respect to the dimensions of the aerosol filters, and a new sample holder and a Faraday cup (FC) were made. The first results of the PIXE aerosol analysis are presented in this paper. Furthermore, the geometric efficiency of the detection system was verified using 55Fe radioactive source emitting monoenergetic Mn X-ray lines. The measured data were compared with the Monte Carlo simulations regarding/disregarding the X-ray attenuation.

1 January 2024 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
RRRobert Riedlmajer
Robert Riedlmajer
JDJozef Dobrovodský
Jozef Dobrovodský
DVDušan Vaňa
Dušan Vaňa
PNPavol Noga
Pavol Noga
MMMartin Muška
Martin Muška
MBMatúš Beňo
Matúš Beňo
One of the significant activities of the Ion Beam Laboratory at the ATRI MTF STU located in Trnava is high energy ion implantation and modification of materials. The original installation of HVE 6 MV Tandetron™ tandem accelerator was equipped with SO358 Duoplasmatron ion source with a Na charge exchange cell for negative He beam generation and with the SO860C Cesium sputtering ion source for protons and other species negative beams. Recently the complete ion injector compromising of the NEC TORVIS (Toroidal Volume Ion Source) ion source, pre-acceleration, analyzing magnet, focusing and beam monitoring elements were added to Tandetron injector beamline. The TORVIS injector was originally installed and used with the NEC 5 MV Pelletron tandem accelerator in Harwell. The advantage of the TORVIS ion source is declared long-term stable and reliable operation, since with the typical maintenance interval 1000 hours. After re-installation, at least the same negative He− and H− beam currents were achieved as were operated during the previous installation. On the Faraday cup of the injector, these values were 5.6 µA for He− and 35 µA for H−, respectively. Consequently, the beam currents after acceleration behind the high energy magnet were 2.1 µA for He+ and 9 µA for H+ beams. Long-term stable operation was confirmed during the testing operation. The TORVIS system must still be tuned to achieve the declared currents of 20 µA for He− and 100 µA for H− at the injector Faraday cup.

1 August 2015 in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
Verified
Journal Article
Open access
SMStanislav Minarik
Stanislav Minarik
RRRobert Riedlmajer
Robert Riedlmajer
This paper offers a theoretical study of special type of electrostatic quadrupole deflection system (EQDS) intended for ion beam optics. We deal with EQDS consisting of electrode pairs with rotational symmetry design. This systems was pre-designed for an ion beam modification and trajectory controlling. Basic assumptions for determination of transfer characteristics of such systems are analysed on the basic of charged particle dynamics. We are especially interested in the electrostatic field distribution among electrodes inside the mentioned type of EQDS. Typical case of the Sturm-Liouville boundary value problem called Bessel`s differential equation arises in calculation of the electrostatic scalar potential with rotational symmetry. Bessel`s functions are particular solution of Laplace equation in this case. The scalar potential equations of motion for ions in this electrostatic field are found. The path of charge-particles in this field could be determined by solving the trajectory equation of motion in Cartesian coordinates.

1 September 2018 in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
Verified
Journal Article
Open access
PDF file
JDJozef Dobrovodský
Jozef Dobrovodský
DVDušan Vaňa
Dušan Vaňa
MBMatúš Beňo
Matúš Beňo
AZAnna Závacká
Anna Závacká
MMMartin Muška
Martin Muška
RRRobert Riedlmajer
Robert Riedlmajer
The new Ion Beam Centre (IBC) equipped with 6 MV tandem ion accelerator and 500 kV ion implanter systems was built at the Slovak University of Technology, Faculty of Materials Science and Technology ( STU MTF). The facility provides Ion Beam Modification of Materials (IBMM) and Ion Beam Analysis (IBA), which includes Rutherford Backscattering Spectrometry (RBS), Particle Induced X-ray Analysis (PIXE), Elastic Recoil Spectrometry (ERDA) and Nuclear Reaction Analysis (NRA). Presented are selected experimental procedures carried out in the IBC during the first year of operation. They present examples of a typical IBA performed, such as thin film characterisation in nm to tens of µm range, elemental depth profiles and sensitivity to the light elements enhancement by non-Rutherford cross-section regime application along with the crystalline sample channelling spectra and boron content measurement.