Increased amplitude of peripheral vasomotion is a potential early marker of sepsis‐related microcirculatory impairment; however, previous reports relied on clinically unsuitable invasive techniques. Hyperspectral near‐infrared spectroscopy (hsNIRS) and diffuse correlation spectroscopy (DCS) are non‐invasive, bedside techniques that can be paired to continuously monitor tissue hemoglobin content (HbT), oxygenation (StO 2 ), and perfusion (rBF) to detect vasomotion as low‐frequency microhemodynamic oscillations. While previous studies have primarily focused on the peripheral microcirculation, cerebral injury is also a common occurrence in sepsis and hsNIRS‐DCS could be used to assess cerebral microcirculatory function. This work aimed to use a hybrid hsNIRS‐DCS system to continuously monitor changes in the peripheral and cerebral microcirculation in a rat model of early sepsis. It was hypothesized that the skeletal muscle would be a more sensitive early indicator of sepsis‐related changes in microhemodynamics than the brain. Control animals received saline while the experimental group received fecal slurry to induce sepsis. Subsequently, hsNIRS‐DCS measurements were acquired from the skeletal muscle and brain for 6 h. Peripheral rBF rapidly decreased in septic animals, but there were no significant changes in peripheral HbT or StO 2 , nor cerebral HbT, rBF, or StO 2 . The power of low‐frequency peripheral oscillations in all parameters (i.e., HbT, StO 2 , and rBF) as well as cerebral HbT oscillations were elevated in septic animals during the final 4 h. These findings suggest that in the early stages of sepsis, while vital organs like the brain are partly protected, changes in peripheral perfusion and vasomotor activity can be detected using hsNIRS‐DCS. Future work will apply the technique to ICU patients.
SignificanceCerebral oximeters have the potential to detect abnormal cerebral blood oxygenation to allow for early intervention. However, current commercial systems have two major limitations: (1) spatial coverage of only the frontal region, assuming that surgery-related hemodynamic effects are global and (2) susceptibility to extracerebral signal contamination inherent to continuous-wave near-infrared spectroscopy (NIRS).AimThis work aimed to assess the feasibility of a high-density, time-resolved (tr) NIRS device (Kernel Flow) to monitor regional oxygenation changes across the cerebral cortex during surgery.ApproachThe Flow system was assessed using two protocols. First, digital carotid compression was applied to healthy volunteers to cause a rapid oxygenation decrease across the ipsilateral hemisphere without affecting the contralateral side. Next, the system was used on patients undergoing shoulder surgery to provide continuous monitoring of cerebral oxygenation. In both protocols, the improved depth sensitivity of trNIRS was investigated by applying moment analysis. A dynamic wavelet filtering approach was also developed to remove observed temperature-induced signal drifts.ResultsIn the first protocol (28±5 years; five females, five males), hair significantly impacted regional sensitivity; however, the enhanced depth sensitivity of trNIRS was able to separate brain and scalp responses in the frontal region. Regional sensitivity was improved in the clinical study given the age-related reduction in hair density of the patients (65±15 years; 14 females, 13 males). In five patients who received phenylephrine to treat hypotension, different scalp and brain oxygenation responses were apparent, although no regional differences were observed.ConclusionsThe Kernel Flow has promise as an intraoperative neuromonitoring device. Although regional sensitivity was affected by hair color and density, enhanced depth sensitivity of trNIRS was able to resolve differences in scalp and brain oxygenation responses in both protocols.
Quantification of cytochrome-c-oxidase (CCO) can directly inform about cerebral metabolic capacity and function, but limited options currently exist for its in vivo assessment. Near-infrared spectroscopy (NIRS) has the potential to quantify CCO and its redox states, but hyperspectral absorption measurements are required due to their broad absorption profiles and low concentrations relative to hemoglobin. While this may be achieved with continuous-wave broadband NIRS (bNIRS), separating the signal contributions of absorption and scattering remains a challenge. Alternatively, time-resolved NIRS (trNIRS) can directly disentangle absorption and scattering but is typically constrained to a few wavelengths. This work aimed to develop an approach for quantifying absolute CCO concentration using discrete-wavelength trNIRS to calibrate bNIRS, yielding calibrated bNIRS (cbNIRS). Monte-Carlo simulations were conducted to validate the algorithm. Subsequently, a hybrid cbNIRS system was assembled, and tissue-mimicking phantoms were prepared with blood, Intralipid, and either yeast or sodium dithionite for validation. The simulations demonstrated that the algorithm can accurately measure absorption across the spectral range (error = 0.8 ± 0.4%). Further, the concentrations of CCO and its different redox states were estimated with an error of 7.9% or less. In the phantom experiments, the measured HbT concentration increased with the addition of blood, but not yeast nor sodium dithionite, and the value agreed with the expected concentration estimated from the packed cell volume of blood. A large increase in total CCO was measured only after the addition of yeast (1.8 ± 0.4 µM). Transitions in the oxygenation state of hemoglobin and redox state of CCO followed the expected trends as the phantom was deoxygenated and reoxygenated. Additionally, the sodium dithionite experiments confirmed that the COO signal measured with cbNIRS is not a result of crosstalk with the hemoglobin signal. This work demonstrates that absolute concentrations of both redox states of CCO can be quantified with high accuracy using cbNIRS. Future work will assess the feasibility of in vivo CCO measurements.
This study aimed to investigate the simultaneous response of the cerebral and skeletal muscle microvasculature to the same phenylephrine (PE) boluses. A hybrid optical system that combines hyperspectral near‐infrared spectroscopy (hs‐NIRS) and diffuse correlation spectroscopy (DCS) was used to monitor changes in tissue oxygenation and perfusion. Data were collected from the head and hind limb of seven male Sprague–Dawley rats while administering intravenous (IV) injections of PE or saline to all animals. The response to saline was used as a control. Skeletal muscle oxygenation decreased significantly after PE injection, while a statistically underpowered decrease in perfusion was observed, followed by an increase beyond baseline. Vascular conductance also decreased in the muscle reflecting the drug's vasoconstrictive effects. Tissue oxygenation and perfusion increased in the brain in response to PE. Initially, there was a sharp increase in cerebral perfusion but no changes in cerebral vascular conductance. Subsequently, cerebral flow and vascular conductance decreased significantly below baseline, likely reflecting autoregulatory mechanisms to manage the excess flow. Further, fitting an exponential function to the secondary decrease in cerebral perfusion and increase in muscular blood flow revealed a quicker kinetic response in the brain to adjust blood flow. In the skeletal muscle, PE caused a transient decrease in blood volume due to vasoconstriction, which resulted in an overall decrease in hemoglobin content and tissue oxygen saturation. Since PE does not directly affect cerebral vessels, this peripheral vasoconstriction shunted blood into the brain, resulting in an initial increase in oxygenated hemoglobin and oxygen saturation.
We used a novel, depth-enhanced optical monitoring system to investigate low-frequency hemodynamic oscillations (0.02–0.16 Hz) in cerebral microvascular perfusion, oxygenation, and relative metabolic rate of oxygen in patients with MCI and cognitively intact controls. Our findings indicate cerebrovascular dysfunction in MCI, wherein the regulation of oxygenation is altered to maintain metabolism in an environment with attenuated vascular control. These findings highlight the potential of using optical technology to assess cerebrovascular function in MCI.
Near-infrared spectroscopy (NIRS) is an effective technique for noninvasive monitoring of cerebral hemodynamics, especially in neonates due to their thinner scalp and skull.1–5 To quantify tissue blood content and oxygenation with NIRS, the effects of light scattering must be separated from those of absorption. This can be achieved with continuous-wave hyperspectral NIRS (h-NIRS), which estimates the concentrations of oxy- and deoxy-hemoglobin (HbO and Hb) from light attenuation at dozens of wavelengths rather than just a discrete few. In this approach, the contribution of scattering is dampened, and absolute absorption is estimated through spectral differentiation.6–15 Moreover, h-NIRS uses simple instrumentation and computationally efficient algorithms, unlike frequency-domain and time-resolved NIRS, making it a promising approach for wider clinical adoption.16–19 Currently, most h-NIRS devices for in vivo tissue monitoring are based on custom-built spectrometers12,20–26; however, the development of low-cost, miniature, off-the-shelf spectrometers would offer several advantages, including greater accessibility, smaller footprint, and portability for point-of-care applications.