J. Morgan Micheletti, MD

Dr. J. Morgan Micheletti, MD

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2021 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
JMJ. Morgan Micheletti, MD
J. Morgan Micheletti, MD
NWNicole Weber
Nicole Weber
MMMatthew B. McCauley
Matthew B. McCauley
EDErin A. Doe
Erin A. Doe
RCRobert E. Coffee
Robert E. Coffee
MCMichael B. Caplan
Michael B. Caplan
In-the-bag intraocular lens (IOL) dislocation is a well-known complication after cataract surgery. As the number of cataract surgeries performed annually continues to increase, so will the incidence of IOL dislocations requiring surgical correction. Described is a new technique for rescue and refixation of a single-piece acrylic IOL. In this method, a new instrument called the IOL punch is used to create a hole at the optic–haptic junction or along the border of the optic, which acts as an anchor point for centration and subsequent scleral fixation of a dislocated IOL. The IOL punch allows for precise intraocular manipulation of the IOL and is less invasive compared with popular scleral fixation methods. This innovative technique may decrease the risk for postoperative complications and allows patients to maintain or recover previous uncorrected visual acuity by circumventing the need for IOL explantation or exchange.

1 December 2024 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Open access
JMJ. Morgan Micheletti, MD
J. Morgan Micheletti, MD
MBMatthew Brink
Matthew Brink
JBJacob W. Brubaker
Jacob W. Brubaker
DRDeborah Do Ristvedt
Deborah Do Ristvedt
SSSteven Sarkisian
Steven Sarkisian
One of the most impactful recent developments in the glaucoma community has been the concept of interventional glaucoma. In brief, this paradigm shift involves proactive rather than reactive intervention to address glaucoma earlier in the disease process, including in both standalone and combination-cataract settings. By intervening earlier with minimally invasive surgical, laser, or drug-delivery treatments instead of prolonged topical medications, interventional glaucoma aims to take the burden of medication compliance off the patient. It also allows for standalone surgical interventions rather than letting cataract surgery dictate the glaucoma treatment plan. This interventional mindset has been made possible by the increasing diversity and availability of effective minimally invasive treatment options. With these options as a springboard, it is time to reevaluate and advance the traditional glaucoma treatment paradigm.

30 November 2024 in Ophthalmology and Therapy
Verified
Journal Article
Open access
PDF file
JMJ. Morgan Micheletti, MD
J. Morgan Micheletti, MD
MSMitchell Shultz
Mitchell Shultz
ISInder Paul Singh
Inder Paul Singh
TSThomas W. Samuelson
Thomas W. Samuelson
The glaucoma treatment paradigm is in evolution. The topical medications-first approach is limited by significant barriers such as high rates of nonadherence and side effects including ocular surface disease. The era of interventional glaucoma has seen the development of selective laser trabeculoplasty (SLT), procedural pharmaceuticals, and minimally invasive glaucoma surgeries (MIGS). New and emerging data support the use of these interventional treatment modalities early in the course of glaucoma rather than reserving them for advanced or treatment-recalcitrant cases. The various treatments available represent multiple mechanisms (e.g., trabecular outflow, uveoscleral outflow, aqueous suppression) and modalities (medications, laser, incisional surgery) by which intraocular pressure (IOP) is reduced. Many patients require more than one treatment to achieve adequate IOP reduction and glaucoma control. Comprehensive IOP control—reduction of both mean IOP and IOP fluctuation—can best be achieved by targeting multiple mechanisms of IOP reduction and taking advantage of the attributes of multiple treatment modalities.

1 December 2023 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
JMJ. Morgan Micheletti, MD
J. Morgan Micheletti, MD
MMMatthew B McCauley
Matthew B McCauley
NDNicole Duncan
Nicole Duncan
BHBrad Hall
Brad Hall
Purpose: To determine refractive or biometric variables that might be predictive of increased intermediate vision in patients receiving an Eyhance monofocal intraocular lens (IOL). Methods: This prospective, single-center, bilateral, non-randomized, open-label, observational study included a total of 110 subjects (220 eyes). Subjects had been previously bilaterally implanted with an Eyhance monofocal IOL (Johnson & Johnson Vision Care, Inc.) and were later divided into 2 groups based on their postoperative visual acuity. Subjects that had binocular distance corrected intermediate visual acuity (DCIVA) of 0.2 logMAR or better were classified into the Enhanced Group, and the remaining subjects were classified into the Non-Enhanced Group. Refractive outcomes and biometric measurements were compared between groups. Results: The number of subjects in each group was 61 for the Enhanced Group, and 49 for the Non-Enhanced Group. There were significant differences in pupil size between groups, with pupil sizes in the Enhanced Group significantly smaller than in the Non-Enhanced Group (p < 0.01). Subjects also reported significantly more dysphotopsias in the Non-Enhanced Group compared to the Enhanced Group (p = 0.03). Multiple regression analysis identified pupil size and axial length as significant predictors of increased monocular intermediate vision. Conclusion: The results of this study suggest that pupil size could be a predictor of increased intermediate vision in a patient receiving an Eyhance monofocal IOL. Plain Language Summary: Cataract surgery involves removing an opaque natural lens and replacing it with a clear artificial lens. These artificial lenses are called intraocular lenses (IOLs). There are many different types of IOLs, and each type provides varying degrees of clear vision at far, intermediate, and near distances. Clear vision at intermediate distance is especially important for viewing digital devices. One type of monofocal IOL, the Eyhance (Johnson & Johnson Vision Care, Inc.) was designed to improve the depth of focus. However, it is not well understood why some patients experience increased intermediate vision and some patients do not. The purpose of this study was to determine refractive or biometric variables that might be predictive of increased intermediate vision in patients receiving an Eyhance monofocal IOL. The results of this study suggest that pupil size could be a predictor of increased intermediate vision, and patients with smaller pupils may be more likely to experience increased intermediate vision.

3 December 2023 in Clinical and Experimental Optometry
Verified
Journal Article
Open access
GWGeorge O Waring
George O Waring
MBMile Brujic
Mile Brujic
SMSelina McGee
Selina McGee
JMJ. Morgan Micheletti, MD
J. Morgan Micheletti, MD
CZCathy Zhao
Cathy Zhao
ESEleonora Safyan
Eleonora Safyan
Patients prescribed pilocarpine ophthalmic solution are advised to be cautious when driving at night, but studies evaluating the effects of pilocarpine hydrochloride ophthalmic solution 1.25% (pilo), approved to treat presbyopia, on driving at night are lacking. This double-masked, crossover, phase 3b study evaluated night-driving performance with pilo or the placebo once daily. Forty-three adults (40-55 years) with presbyopia impacting daily activities and mesopic, high-contrast, binocular distance-corrected near vision 6/12-6/30 were randomised to bilateral treatment with pilo followed by placebo or placebo followed by pilo (with a ≥7-day washout between interventions). Night-driving performance was evaluated at twilight at a closed-circuit course. Primary efficacy endpoint: overall composite night-driving performance Z score at the end of the 7-14-day intervention period, 1 hour post-instillation. Pilo was considered non-inferior if the lower limit of the 95% confidence interval (CI) for the least squares mean difference (LSMD, pilo minus placebo) was >-0.25. Other efficacy endpoints: individual components of the night-driving performance test (hazard avoidance rate; road sign recognition rate and distance; pedestrians recognition distance; overall driving and lane-keeping times) and night-driving experience questionnaire. Safety included treatment-emergent adverse events (TEAEs). The mean overall composite Z scores were -0.121 (pilo) and 0.118 (placebo). The LSMD (pilo minus placebo) was -0.224 (95% CI, -0.346, -0.103), with 3 of the 7 individual tasks being significantly better with the placebo. The questionnaire did not reveal significant differences between pilo and the placebo. There were no serious or severe TEAEs and no TEAE-related discontinuations. The most common ocular TEAEs were headache and visual impairment with pilo (both 27.9%), and dry eye (7.0%) with the placebo. The overall performance of night driving was inferior with pilo, compared with placebo. The study findings are consistent with the current class labelling and provide evidence to inform regulators and assist clinicians considering prescribing pilo to adults who seek treatment of presbyopia symptoms and drive at night.ClinicalTrials.gov identifier: NCT04837482.

1 January 2025 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
JMJ. Morgan Micheletti, MD
J. Morgan Micheletti, MD
BHBrad Hall
Brad Hall
HSHayden G Smiley
Hayden G Smiley
WLWilliam J Langston
William J Langston
Purpose: To determine if visual outcomes with PanOptix are non-inferior to visual outcomes with Synergy. Methods: This was an ambispective, single center, comparative, bilateral, observational study. Patients received bilateral implantation with either PanOptix or Synergy intraocular lenses (IOLs) and were enrolled at least 5 months after surgeries. Patients with postoperative spherical equivalent ± 0.50D and astigmatism ≤ 0.75D in both eyes were enrolled. Postoperatively, patients were tested for binocular uncorrected and distance corrected visual acuities at distance, intermediate (60cm), and near (40cm and 33cm), binocular defocus curve, and were administered questionnaires about quality of vision (QUVID) and spectacle independence (IOLSAT). Results: A total of 230 subjects completed the study, 153 in the PanOptix group and 77 in the Synergy group. Non-inferiority of visual acuities were confirmed for all testing distances, with and without distance correction in place. No significant differences were observed for the binocular defocus curves (p > 0.05). Severity of starburst, halo, and glare were rated as “None” in 65% (98/150), 38% (58/152), and 48% (72/151) of subjects with the PanOptix Group, compared to 49% (37/76), 38% (29/77), and 55% (42/77) for the Synergy Group, respectively. The percentage of patients “Satisfied” or “Very Satisfied” with their vision was 89% (136/153) in the PanOptix group and 94% (72/77) in the Synergy group. Conclusion: The results of this study suggest excellent visual acuities at distance, intermediate, and near, high spectacle independence, and high patient satisfaction with both the PanOptix and Synergy IOLs. The incidence of starbursts and blurred vision, as well as visual acuities at extreme near (33 cm), may be higher with the Synergy IOL.