Among various non-contact direct ink writing techniques, aerosol jet printing (AJP) stands out due to its distinct advantages, including a more adaptable working distance (2–5 mm) and higher resolution (~ 10 μm). These characteristics make AJP a promising technology for the precise customization of intricate electrical functional devices. However, complex interactions among the machine, process, and materials result in low controllability over the electrical performance of printed lines. This significantly affects the functionality of printed components, thereby limiting the broad applications of AJP. Therefore, a systematic machine learning approach that integrates experimental design, geometrical features extraction, and non-parametric modeling is proposed to achieve printing quality optimization and electrical resistivity prediction for the printed lines in AJP. Specifically, three classical convolutional neural networks (CNNs) architectures are compared for extracting representative features of printed lines, and an optimal operating window is identified to effectively discriminate better line morphology from inferior printed line patterns within the design space. Subsequently, three representative non-parametric machine learning techniques are employed for resistivity modeling. Following that, the modeling performances of the adopted machine learning methods were systematically compared based on four conventional evaluation metrics. Together, these aspects contribute to optimizing the printed line morphology, while simultaneously identifying the optimal resistivity model for accurate predictions in AJP.
14 June 2023 in IEEE Robotics and Automation Letters
Exosuits can be effective in aiding stroke rehabilitation. However, single-motor exosuits are challenging to adapt to users with different body sizes. Methods: This letter proposes an electromagnetic clutch-based ankle exosuit (ECAE) for stroke survivors with different body sizes. This exosuit includes a single-motor actuation unit, two novel electromagnetic ratchet clutches, and functional textiles. Compared with other ankle rehabilitation robots, this exsouit could adapt to different users in terms of adaptive preload after wearing, maintaining device transparency when unpowered, and providing timely assistance. Experiments: Benchtop experiments were constructed to evaluate the property of designed clutches. Fifteen healthy subjects with different body sizes wore the ECAE to verify its adaptive performance. Then, they walked with unpowered and powered exosuits to validate transparency and timely assistive performance, respectively. Results: Designed clutches have a fast switching response (<20 ms). The ECAE could adaptively adjust the cable length with a slight preload (0.32–1.31 N) for different users. Compared with this exosuit without designed clutches, device transparency is increased by 84.58% (P < 0.001), and the assistive delay time is reduced by 57.77% (P < 0.004). Conclusion: This ECAE could adapt to different users without needing customization, which could reduce the price of exosuits.
The ion energy and angular distributions of H+, , and impinging on an extraction aperture (3 mm in radius) have been investigated with a hybrid model of an inductively coupled H2 ion source. A dc is applied at the end of the cylinder discharge chamber, which pulls these three ions toward the extraction aperture. With an increase in the bias voltage, their ion angular distributions (IADs) become more symmetrical about the 0° axis and the full width at half-maximum (FWHM) of their IADs shrinks continuously. On the other hand, the ion-energy distributions (IEDs) of the three ions first form a single peak ( 50 V) and then have a bimodal structure at 50 V 290 V. Finally, they return to a single peak at high bias voltage ( 290 V). The interval between two IED peaks ( ) first increases to a maximum around 150 V and then decreases monotonously. This can be attributed to the variation of the ratio of the ion transit time through the sheath (τi) to the rf field period (τrf). Moreover, the FWHMs of IEDs of H+, , and first increase to 2.62, 2.45, and 2.32 eV around Vbias = 150 V, respectively, and then decrease continuously with the bias voltage. Using a low rf power and low gas pressure may help to narrow the FWHM of the IEDs of the three ions. The hybrid model is verified by comparing the results from the simulation and experiment, and they exhibit a qualitative agreement. The results in this work could lead to deeper insights into the dependence of IADs and IEDs on the discharge parameters, which is important for realizing a monoenergetic and collimated ion beam in a proton or an ion accelerator.
Nonlinear mapping is an essential and common demand in online systems, such as sensor systems and mobile phones. Accelerating nonlinear mapping will directly speed up online systems. Previously the authors of this paper proposed a Dendrite Net (DD) with enormously lower time complexity than the existing nonlinear mapping algorithms; however, there still are redundant calculations in DD. This paper presents a DD with an acceleration module (AC) to accelerate nonlinear mapping further. We conduct three experiments to verify whether DD with AC has lower time complexity while retaining DD’s nonlinear mapping properties and system identification properties: The first experiment is the precision and identification of unary nonlinear mapping, reflecting the calculation performance using DD with AC for basic functions in online systems. The second experiment is the mapping precision and identification of the multi-input nonlinear system, reflecting the performance for designing online systems via DD with AC. Finally, this paper compares the time complexity of DD and DD with AC and analyzes the theoretical reasons through repeated experiments. Results: DD with AC retains DD’s excellent mapping and identification properties and has lower time complexity. Significance: DD with AC can be used for most engineering systems, such as sensor systems, and will speed up computation in these online systems.
Objective. Vibrotactile stimulation (VS) has been widely used as an appropriate motor imagery (MI) guidance strategy to improve MI performance. However, most VS induced by a single vibrator cannot provide spatiotemporal information of tactile sensation associated with the visual guidance of the imagined motion process, not vividly providing MI guidance for subjects. Approach. This paper proposed a paradigm with visual and spatiotemporal tactile synchronized stimulation (VSTSS) to provide vivid MI guidance to help subjects perform lower-limb MI tasks and improve MI-based brain-computer interface (MI-BCI) performance, with a focus on poorly performing subjects. The proposed paradigm provided subjects with the natural spatiotemporal tactile sensation associated with the visual guidance of the foot movement process during MI. Fourteen healthy subjects were recruited to participate in the MI and Rest tasks and divided into good and poor performers. Furthermore, electrophysiological features and classification performance were analyzed to assess motor cortical activation and MI-BCI performance under no VS (NVS), VS, and VSTSS. Main results. The phenomenon of event-related desynchronization (ERD) in the sensorimotor cortex during MI under the VSTSS was more pronounced compared to the NVS and VS. Specifically, the VSTSS could improve the average ERD values in the motor cortex during the task segment by 34.70% and 14.28% than the NVS and VS in the alpha rhythm for poor performers, respectively. Additionally, the VSTSS could significantly enhance the classification accuracy between the MI and Rest tasks by 12.52% and 4.05% compared to NVS and VS for poor performers, respectively. Significance. The proposed paradigm could enhance motor cortical activation during MI and improve classification performance by providing vivid MI guidance for subjects, offering a promise for the application of lower-limb MI-BCI in stroke rehabilitation in the future.
INPLASY202090051 Baduanjin exercise for patients with knee osteoarthritis: a protocol for systematic review and meta-analysis Keywords: Baduanjin exercise; knee osteoarthritis; systematic review; meta-analysis. Download PDF – 202090051