Mary McDougall

Mary McDougall


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2009 in Concepts in Magnetic Resonance Part B
Verified
Journal Article
Closed access
PDF file
ADArash Dabirzadeh
Arash Dabirzadeh
MMMary McDougall
Mary McDougall

24 January 2014 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
MMMary McDougall
Mary McDougall
SCSergey Cheshkov
Sergey Cheshkov
JRJoseph Rispoli
Joseph Rispoli
CMCraig Malloy
Craig Malloy
IDIvan Dimitrov
Ivan Dimitrov
SWSteven M. Wright
Steven M. Wright

24 November 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SBSamantha By
Samantha By
JRJoseph Rispoli
Joseph Rispoli
SCSergey Cheshkov
Sergey Cheshkov
IDIvan Dimitrov
Ivan Dimitrov
JCJiaming Cui
Jiaming Cui
MMMary McDougall
Mary McDougall
To enable high spatial and temporal breast imaging resolution via combined use of high field MRI, array coils, and forced current excitation (FCE) multi channel transmit. A unilateral 16-channel receive array insert was designed for use in a transmit volume coil optimized for quadrature operation with dual-transmit RF shimming at 7T. Signal-to-noise ratio (SNR) maps, g-factor maps, and high spatial and temporal resolution in vivo images were acquired to demonstrate the utility of the coil architecture. The dual-transmit FCE coil provided homogeneous excitation and the array provided an increase in average SNR of 3.3 times (max 10.8, min 1.5) compared to the volume coil in transmit/receive mode. High resolution accelerated in vivo breast imaging demonstrated the ability to achieve isotropic spatial resolution of 0.5 mm within clinically relevant 90 s scan times, as well as the ability to perform 1.0 mm isotropic resolution imaging, 7 s per dynamics, with the use of bidirectional SENSE acceleration of up to R = 9. The FCE design of the transmit coil easily accommodates the addition of a sixteen channel array coil. The improved spatial and temporal resolution provided by the high-field array coil with FCE dual-channel transmit will ultimately be beneficial in lesion detection and characterization.

7 August 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Matthew WilcoxMatthew Wilcox
Matthew Wilcox
SWSteven M. Wright
Steven M. Wright
MMMary McDougall
Mary McDougall
The method of pole-insertion for multi-tuning cable traps was studied for multinuclear MRI and MRS applications. For many applications such as when using high-density array coils, finding a space-efficient solution to eliminate common-mode currents could be of significant benefit. This multi-tuned approach provides space efficiency at a small cost in trapping efficiency. Relative efficiency of the different cable trap modes was studied as component values were varied and at four different magnetic field strengths. In all cases, efficiencies were compared to equivalent single-tuned designs. The multi-tuned traps were able to block shield currents at multiple frequencies with only slightly degraded efficiencies as compared to their single-tuned counterparts. As in double-tuned coil design, the cable trap effectiveness at each frequency was found to be highly dependent on the trap inductor value with larger trap inductances leading to worse efficiency at the lower frequency but better efficiency at the higher frequency. This relationship held at all field strengths examined. This work presents design guidelines for the double-tuning method that are useful when designing RF coils for multinuclear studies. The design takes up less space than using two single-tuned cable traps mounted in series as is commonly done. Triple-tuned and “floating” designs were also demonstrated as proofs-of-concept for a single field strength and showed great promise to prove similarly useful in future studies.

23 May 2011 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
CKChiwan Koo
Chiwan Koo
RGRichard F. Godley
Richard F. Godley
JPJaewon Park
Jaewon Park
MMMary McDougall
Mary McDougall
SWSteven M. Wright
Steven M. Wright
Arum HanArum Han
Arum Han
We present the development of a microfluidically cryo-cooled planar coil for magnetic resonance (MR) microscopy. Cryogenically cooling radiofrequency (RF) coils for magnetic resonance imaging (MRI) can improve the signal to noise ratio (SNR) of the experiment. Conventional cryostats typically use a vacuum gap to keep samples to be imaged, especially biological samples, at or near room temperature during cryo-cooling. This limits how close a cryo-cooled coil can be placed to the sample. At the same time, a small coil-to-sample distance significantly improves the MR imaging capability due to the limited imaging depth of planar MR microcoils. These two conflicting requirements pose challenges to the use of cryo-cooling in MR microcoils. The use of a microfluidic based cryostat for localized cryo-cooling of MR microcoils is a step towards eliminating these constraints. The system presented here consists of planar receive-only coils with integrated cryo-cooling microfluidic channels underneath, and an imaging surface on top of the planar coils separated by a thin nitrogen gas gap. Polymer microfluidic channel structures fabricated through soft lithography processes were used to flow liquid nitrogen under the coils in order to cryo-cool the planar coils to liquid nitrogen temperature (−196 °C). Two unique features of the cryo-cooling system minimize the distance between the coil and the sample: (1) the small dimension of the polymer microfluidic channel enables localized cooling of the planar coils, while minimizing thermal effects on the nearby imaging surface. (2) The imaging surface is separated from the cryo-cooled planar coil by a thin gap through which nitrogen gas flows to thermally insulate the imaging surface, keeping it above 0 °C and preventing potential damage to biological samples. The localized cooling effect was validated by simulations, bench testing, and MR imaging experiments. Using this cryo-cooled planar coil system inside a 4.7 Tesla MR system resulted in an average image SNR enhancement of 1.47 ± 0.11 times relative to similar room-temperature coils.

1 October 2016 in Concepts in Magnetic Resonance Part B
Verified
Journal Article
Open access
PDF file
JRJoseph Rispoli
Joseph Rispoli
IDIvan E. Dimitrov
Ivan E. Dimitrov
SCSergey Cheshkov
Sergey Cheshkov
CMCraig Malloy
Craig Malloy
SWSteven M. Wright
Steven M. Wright
MMMary McDougall
Mary McDougall
Performing multinuclear experiments requires one or more radiofrequency (RF) coils operating at both the proton and second‐nucleus frequencies; however, inductive coupling between coils must be mitigated to retain proton sensitivity and coil tuning stability. The inclusion of trap circuits simplifies placement of multinuclear RF coils while maintaining inter‐element isolation. Of the commonly investigated non‐proton nuclei, perhaps the most technically demanding is carbon‐13, particularly when applying a proton decoupling scheme to improve the resulting spectra. This work presents experimental data for trap circuits withstanding high‐power broadband proton decoupling of carbon‐13 at 7 T. The advantages and challenges of building trap circuits with various inductor and capacitor components are discussed. Multiple trap designs are evaluated on the bench and utilized on an RF coil at 7 T to detect broadband proton‐decoupled carbon‐13 spectra from a lipid phantom. A particular trap design, built from a coaxial stub inductor and high‐voltage ceramic chip capacitors, is highlighted owing to both its performance and adaptability for planar array coil elements with diverse spatial orientations.