Yingying Qiao

Ms. Yingying Qiao


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2010 in Optics Communications
Verified
Journal Article
Closed access
LLLanlan Li
Lanlan Li
JWJian Wu
Jian Wu
YQYingying Qiao
Yingying Qiao
BWBingbing Wu
Bingbing Wu
KXKun Xu
Kun Xu
JLJintong Lin
Jintong Lin

21 January 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LLLei Li
Lei Li
XZXiya Zheng
Xiya Zheng
YGYang Gao
Yang Gao
ZHZhiyong Hu
Zhiyong Hu
JZJiale Zhao
Jiale Zhao
YQYingying Qiao
Yingying Qiao
The flow field is one of the key factors that affect the measuring accuracy of ultrasonic gas flowmeters. The present work demonstrates that the designed novel flow conditioner can enhance the measurement accuracy by homogenizing the velocity profile in the acoustic transmission area. The main objective of this study is to reduce the non-uniformity of flow on velocity distribution. To accomplish this objective, a combination of theoretical analysis and numerical simulations is implemented, and the results indicate that the 10:1 aspect ratio rectangular fluid channel is better applied in ultrasonic gas flowmeters. Thus, a Computational Fluid Dynamics (CFD) model of novel flow conditioner based on the 10:1 fluid channel is simulated and validated by an experimental study. The results verify that the ultrasonic gas flowmeter composed of designed flow conditioner can reduce indication errors by up to 6%; moreover, the repeatability of all the tested standard flow rates can meet the national standard and even be enhanced by 0.15%.

1 May 2018 in IEEE Photonics Journal
Verified
Journal Article
Open access
YTYe Tian
Ye Tian
JQJifang Qiu
Jifang Qiu
MYMingbin Yu
Mingbin Yu
ZHZhuili Huang
Zhuili Huang
YQYingying Qiao
Yingying Qiao
Jian WuJian Wu
Jian Wu
In this paper, we propose and fabricated a novel scheme of SOI-based 1$\times$3 coupler with variable splitting ratio. The coupler consists of two cascaded MMI with different sizes, and a wide range of splitting ratios from 1:0.1:1 to 1:18:1 can be achieved by modifying the size of the first-step MMI. Using the structure of cascaded step-size MMI, this kind of device has a compact footprint of below 15 μm$\times$15 μm and simple fabrication process. Meanwhile, the simulation analyses prove that the proposed couplers have a large operation bandwidth above 60 nm and be robust to the fabrication errors. Couplers with several splitting ratios were fabricated and well measured. Based on the measurement results, the splitting ratios of fabricated couplers from 1:0.67:1 to 1:18:1 can be achieved, and stable performance with the transmission efficiencies above 80% can be maintained over 50 nm wavelength range, which is the largest operation bandwidth to the best of our knowledge.

15 January 2025 in Analytical Chemistry
Verified
Journal Article
Closed access
DDDou Dou
Dou Dou
MJMingqi Jiao
Mingqi Jiao
MFMingyang Feng
Mingyang Feng
MLMu Liang
Mu Liang
KMKaijun Mu
Kaijun Mu
CSChongxin Shan
Chongxin Shan

17 May 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
YQYingying Qiao
Yingying Qiao
JTJIFANG TAO
JIFANG TAO
CCChia-Hung Chen
Chia-Hung Chen
JQJifang Qiu
Jifang Qiu
YTYe Tian
Ye Tian
Jian WuJian Wu
Jian Wu
A miniature methane sensor composed of a long ultra-low loss waveguide and a micro-ring resonator filter is proposed with high sensitivity and good selectivity. This sensor takes advantage of the evanescent field to implement methane concentration detection at a near infrared band (1650 nm). In the sensor, two waveguides, a strip waveguide and a slot waveguide, are specially designed and discussed based on three common semiconductor materials, including silica, silicon nitride, and silicon. Through simulations and numerical calculations, we determine that for the strip waveguide, the optimal evanescent field ratio (EFR) is approximately 39.8%, while the resolution is 32.1 ppb using a 15-cm waveguide length. For the slot waveguide, the optimal EFR is approximately 61.6%, and the resolution is 20.8 ppb with a 15-cm waveguide length.

19 August 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YGYang Gao
Yang Gao
YZYong Zeng
Yong Zeng
MCMingming Cui
Mingming Cui
YQYingying Qiao
Yingying Qiao
Xun YangXun Yang
Xun Yang
Chong-Xin ShanChong-Xin Shan
Chong-Xin Shan
This article presents a diamond nitrogen-vacancy (NV) center-based magnetic field sensor using a voltage-controlled oscillator (VCO) integrated with a filtering antenna. In existing NV-based quantum sensing systems, microwave source and delivery units are implemented by a set of bulky and costly instruments. This limits its practical applications as well as portability. Here, a VCO integrated with the filtering antenna is designed, providing a more uniform, efficient, broadband and lower phase noise microwave field coupling to the NV centers. As a result, the sensitivity and the dynamic range have been improved over the conventional scheme using separate microwave components, such as antennas, transmission lines, and resonators. Moreover, in this work, the optic filter and photodetector are also integrated using the hybrid microwave integrated circuits (HMICs) technique for the first time. This significantly increases the integration level and reduces the cost of the NV-based magnetometers. The experimental results indicate that our VCO integrated filtering antenna achieves a sensitivity of $8.52~\mu \text{T}$ /Hz $^{\mathrm {1/2}}$ and a dynamic range up to 32.73 dB, which are both greatly improved compared to the VCO with a single resonator. This validates the effectiveness of the approach.