This paper aims to assess the efficacy of the Harris Hawk Optimization (HHO) algorithm within the domain of photovoltaic (PV) power-generation systems. The focus lies in elucidating how the HHO algorithm optimizes maximum-power-point tracking (MPPT) and augments the performance of grid-connected PV systems. Initially, in the MATLAB/Simulink environment, a comparison is made between the HHO algorithm and two other extensively utilized methods for maximum-power-point tracking (MPPT): Perturb and Observe (P&O) and Particle Swarm Optimization (PSO). Preliminary findings indicate the HHO algorithm’s notable advantages in efficiency and speed over the other algorithms. Furthermore, by establishing a practical experimental platform and synchronously verifying outcomes through simulation, we conducted a comprehensive assessment of the HHO algorithm on a single-phase full-bridge-inverter grid-connected system. Results show the HHO algorithm’s exceptional optimization capabilities, which displays superior adaptability and ability to adjust to varying external conditions.
To address voltage fluctuations, low renewable energy permeability, and high power loss in low-voltage distribution networks (LVDNs) integrated with photovoltaic (PV) and energy storage systems (ESSs), a Chaotic Particle Swarm Optimization (PSO)-based hierarchical optimal operation method is proposed. Firstly, the mathematical model for grid-forming control (GFM)-based PV and ESSs in LVDNs is developed. Then, the multi-objective optimization problem is formulated to: (1) minimize voltage deviation, (2) maximize PV generation power, and (3) minimize power losses. Next, the objectives are ranked based on priority, and the multi-objective optimization problem is split into several single-objective sub-problems, each solved with the chaotic PSO algorithm. Several test studies confirm that the proposed strategy achieves faster convergence (68 iterations vs. 142, reducing total computation time by 36.9%), along with a marginal accuracy improvement over standard PSO. Finally, both simulation and hardware-in-the-loop (HIL) experimental results demonstrate the effectiveness and reliability of the proposed operation scheme in LVDNs.
The integration of a large number of voltage source converters (VSCs) into the power grid decreases the small-signal stability of the power system. When several VSCs with different control parameters are simultaneously connected to the power grid to form a multi-converter grid-tied system, the potential destabilizing factors increase. Thus, parameter optimization for stability-weakest parameters that have the greatest impact on the system stability becomes more significant in addressing small-signal stability issues. This paper first proposes a stability evaluation function based on the Gerschgorin disc theorem, which can assess the stability of the multi-converter grid-tied system. Then a parameter sensitivity method is proposed to identify the stability-weakest parameters. Finally, an iterative calculation-based parameter optimization method is developed to regulate the identified stability-weakest parameters. Hence, the parameter optimization technique in this research can improve the system stability without requiring eigenvalue solutions and has the merit of low computational complexity. Simulation results based on both the MATLAB/Simulink (2023a) and the RT-LAB (OPAL-RT 5700) platform of a multi-converter grid-tied system validate the correctness of the theoretical analysis and the effectiveness of the parameter optimization method.
With the large-scale integration of Class B distributed photovoltaic power sources without fault-tolerant capabilities, the “pulse blocking-recovery” transient behavior during power grid faults has become a key factor affecting the frequency and voltage stability of the system. The recovery rate of active current after pulse blocking directly determines the speed of filling the active power deficit, but the mechanism of its impact on frequency and voltage stability has not been fully revealed. This paper first establishes a frequency response model for photovoltaic power grids with high penetration considering the pulse blocking control process, quantitatively analyzes the mechanism of the effect of the recovery rate of active current KIp on the minimum frequency value, recovery time, and overshoot quantity, and points out that a too-low KIp will lead to frequency instability, while an excessively high KIp will cause overshoot oscillations. On this basis, an optimization model with KIp as the only decision variable is established with the goal of minimizing the comprehensive cost of frequency response, and the adaptive grid search method is used to efficiently optimize. Finally, a simulation verification was conducted using an actual power grid case from a certain province in China. The simulation results show that the optimized recovery rate (KIp =1.50 p.u./s) is higher than the factory default value (0.10 p.u./s), raising the minimum frequency from 49.1 Hz to 49.82 Hz, shortening the recovery time from the unstable state to 0.60 s, and keeping the overshoot within 0.15 Hz. Compared with the quick recovery condition (3.00 p.u./s), the overshoot has decreased by 46.4% (from 0.28 Hz to 0.15 Hz), and the critical synchronization rate has increased by approximately 8.7% (from 61.8% to 67.2%). This provides a theoretical basis for the standardized management of grid-connected parameters for Class B distributed photovoltaic systems.