Guoqiang Xu

Prof. Guoqiang Xu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
HLHaokun Li
Haokun Li
GXGuoqiang Xu
Guoqiang Xu
JCJiuwang Chen
Jiuwang Chen
DJDuan Junfang
Duan Junfang
In the present study, questionnaires and field measurements were carried out to investigate the thermal sensation, thermal preference, and adaptive behavior of 216 elderly people living in rural mutual aid homes in central Inner Mongolia from 15 December 2020 to 31 December 2020. The main objective of this article was to understand the thermal comfort of the elderly at different ages and provide a reference for the design and construction of mutual aid homes from the perspective of adaptive thermal comfort. The obtained results showed that the average clothing thermal resistance of the elderly is 1.36 clo, and the thermal neutral temperature is 20.52 °C. Moreover, the 80% acceptable temperature range of the elderly is 15.48–25.56 °C, and the thermal expectation temperature is 21.09 °C. Then, an adaptive thermal comfort model was established for the elderly in rural mutual aid hospitals in the region. It was found that the thermal resistance, thermal neutral temperature, and thermal sensitivity of the clothing of the elderly of different ages are significantly different. The difference is especially more pronounced for the elderly over 80 years. Therefore, the differences in the thermal comfort needs of the elderly of different ages should be considered in the construction of rural mutual aid homes. This article is expected to provide a reference for the design of rural mutual aid homes and the update of heating systems.

16 November 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
TZTao Zhiyi
Tao Zhiyi
ZXzhu xiangdong
zhu xiangdong
GXGuoqiang Xu
Guoqiang Xu
DZDezhi Zou
Dezhi Zou
GLGuo Li
Guo Li
Outdoor thermal comfort is an important criterion for evaluating the quality of outdoor activity environments and is also a significant indicator for assessing sustainable building design. Over the past century, more than 165 indoor and outdoor thermal comfort indexes have been developed to define human thermal comfort conditions under various circumstances and to quantify indoor and outdoor thermal environmental conditions. However, in the process of outdoor thermal comfort indicators becoming widely used worldwide, it remains a pressing research issue to compare the current state of application in China and other countries, identify the key areas of application for both sides, and outline the trends in outdoor thermal comfort index application. This study analyzed 346 articles on outdoor thermal comfort indicators. Employing bibliometric methods, we outline the general landscape of outdoor thermal comfort index applications in China and other countries. Additionally, we utilize comparative analysis to uncover similarities and differences in the research focus on outdoor thermal comfort. The research findings indicate the following: (1) Compared to China, other countries started outdoor thermal comfort index application research earlier. Their papers have higher average citation counts and engage in close academic collaborations. However, the quantity of published papers is fewer than in China. (2) The top five frequently used indexes in both China and other countries are PET (including mPET), UTCI, PMV, SET* (including OUT_SET*), and THI (including DI). China tends to use PET and UTCI more frequently than other countries. (3) The potential future directions for outdoor thermal comfort index applications in both China and other countries include: “monitoring and controlling regional outdoor thermal comfort at the temporal and spatial scales”, “multi-factors coupling effects on outdoor thermal comfort”, “human health assessment and prediction based on outdoor thermal comfort”, and “utilizing computational algorithms to calculate outdoor thermal comfort”. This study can serve as a reference for researchers and designers in the industry, contributing to the creation of sustainable outdoor environments.

Jiaxu ZhouJiaxu Zhou
Jiaxu Zhou
XJXiaohu Jia
Xiaohu Jia
GXGuoqiang Xu
Guoqiang Xu
JJJunhan Jia
Junhan Jia
RHRihan Hai
Rihan Hai
SZShuo Zhang
Shuo Zhang
Due to differences in cognitive ability and physiological development, the evacuation characteristics of children are different from those of adults. This study proposes a novel method of using wearable sensors to collect data (e.g., electrodermal activity, EDA; heart rate variability, HRV) on children’s physiological responses, and to continuously and quantitatively evaluate the effects of different types of alarm sounds during the evacuation of children. In order to determine the optimum alarm for children, an on-site experiment was conducted in a kindergarten to collect physiological data for responses to different types of alarm sounds during the evacuation of 42 children of different ages. The results showed that: (1) The alarm sounds led to changes in physiological indicators of children aged 3–6 years, and the effects of different types of alarm sounds on EDA and HRV activities were significantly different (p < 0.05). Skin conductance (SC), skin conductance tonic (SCT) and skin conductance level (SCL) can be used as the main indicators for analysing EDA of children in this experiment (p < 0.05), and the indicators of ultralow frequency (ULF) and very low frequency (VLF) for HRV were not affected by the type of alarm sounds (p > 0.05). (2) Unlike adults, kindergarten children were more susceptible to the warning siren. The combined voice and warning alarm had optimal effects in stimulating children to perceive risk. (3) For children aged 3–6 years, gender had a significant impact on children’s reception to evacuation sound signals (p < 0.05): Girls are more sensitive than boys in receiving evacuation sound signals, similar to findings of studies of risk perception of adult males and females. In addition, the higher the age, the greater the sensitivity to evacuation sound signals, which accords with results of previous studies on the evacuation dynamics of children.

28 January 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
GXGuoqiang Xu
Guoqiang Xu
HJHong Jin
Hong Jin
Jian KangJian Kang
Jian Kang
The Mongolian yurt is a circular dwelling with a wooden frame enclosed by a lightweight felt envelope. In this study, field experiments were conducted to understand the patterns of temperature changes of the yurt’s indoor thermal environment. The study found that the felt’s low thermal inertia affected the indoor temperature stability, resulting in a large difference between day and night temperatures inside the yurt. The felts adjusted the indoor humidity in the case of large outdoor humidity fluctuations, but when the outdoor humidity was very low, the indoor air was drier. Indoor temperatures were generally lower in the centre and higher in the surrounding peripheral areas, and the main influencing factors included felt seams, gaps between the door and Khana, the ground, and solar radiation. The main factor influencing the temperature of the felt wall’s inner surface was solar radiation. The effects on temperature and humidity when opening the component felt pieces were obvious: humidity adjustment was best with the top felt piece opened; indoor temperature adjustment was best with the gaps between the floor and felt wall pieces closed; and the door curtain was most effective for insulation when the outdoor temperature was low.

7 February 2024 in Case Studies in Construction Materials
Verified
Journal Article
Open access
GLGuo Li
Guo Li
GXGuoqiang Xu
Guoqiang Xu
JZJintao Zhang
Jintao Zhang

18 November 2024 in Construction and Building Materials
Verified
Journal Article
Open access
GLGuo Li
Guo Li
PZPengju Zhang
Pengju Zhang
GXGuoqiang Xu
Guoqiang Xu
TGTsovoodavaa Gantumur
Tsovoodavaa Gantumur