Hugo Gaspar

Dr. Hugo Gaspar

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2018 in Materials
Verified
Journal Article
Open access
PDF file
HGHugo Gaspar
Hugo Gaspar
Flavio Alberto da Silva FigueiraFlavio Alberto da Silva Figueira
Flavio Alberto da Silva Figueira
LPLuiz Pereira
Luiz Pereira
Adelio MendesAdelio Mendes
Adelio Mendes
JVJulio C. Viana
Julio C. Viana
Gabriel BernardoGabriel Bernardo
Gabriel Bernardo
Organic photovoltaic (OPV) devices, made with semiconducting polymers, have recently attained a power conversion efficiency (PCE) over 14% in single junction cells and over 17% in tandem cells. These high performances, together with the suitability of the technology to inexpensive large-scale manufacture, over lightweight and flexible plastic substrates using roll-to-roll (R2R) processing, place the technology amongst the most promising for future harvesting of solar energy. Although OPVs using non-fullerene acceptors have recently outperformed their fullerene-based counterparts, the research in the development of new fullerenes and in the improvement of the bulk-heterojunction (BHJ) morphology and device efficiency of polymer:fullerene solar cells remains very active. In this review article, the most relevant research works performed over the last 3 years, that is, since the year 2016 onwards, in the field of fullerene-based polymer solar cells based on the copolymers PTB7, PTB7-Th (also known as PBDTTT-EFT) and PffBT4T-2OD, are presented and discussed. This review is primarily focused on studies that involve the improvement of the BHJ morphology, efficiency and stability of small active area devices (typically < 15 mm2), through the use of different processing strategies such as the use of different fullerene acceptors, different processing solvents and additives and different thermal treatments.

1 September 2011 in Carbon
Verified
Journal Article
Closed access
HGHugo Gaspar
Hugo Gaspar
CPClara Pereira
Clara Pereira
Susana RebeloSusana Rebelo
Susana Rebelo
Manuel Fernando PereiraManuel Fernando Pereira
Manuel Fernando Pereira
José Luís FigueiredoJosé Luís Figueiredo
José Luís Figueiredo
Cristina FreireCristina Freire
Cristina Freire

1 March 2013 in Catalysis Today
Verified
Journal Article
Closed access
HGHugo Gaspar
Hugo Gaspar
Marta AndradeMarta Andrade
Marta Andrade
CPClara Pereira
Clara Pereira
APAndré M. Pereira
André M. Pereira
Susana RebeloSusana Rebelo
Susana Rebelo
Cristina FreireCristina Freire
Cristina Freire

1 February 2006 in Enzyme and Microbial Technology
Verified
Journal Article
Closed access
ACAna Carvalho
Ana Carvalho
IPIsabel Pontes
Isabel Pontes
HGHugo Gaspar
Hugo Gaspar
FMFrancisco Malcata
Francisco Malcata

1 July 2016 in Journal of Neuroscience Methods
Verified
Journal Article
Closed access
PRPasion Rita
Pasion Rita
TPTiago O. Paiva
Tiago O. Paiva
PPPaulo Pedrosa
Paulo Pedrosa
HGHugo Gaspar
Hugo Gaspar
Beatriz VasconcelosBeatriz Vasconcelos
Beatriz Vasconcelos
FBFernando Barbosa
Fernando Barbosa

3 May 2017 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PPPaulo Pedrosa
Paulo Pedrosa
Patrique FiedlerPatrique Fiedler
Patrique Fiedler
VPVanessa Pestana
Vanessa Pestana
Beatriz VasconcelosBeatriz Vasconcelos
Beatriz Vasconcelos
HGHugo Gaspar
Hugo Gaspar
Carlos FonsecaCarlos Fonseca
Carlos Fonseca
A novel quasi-dry electrode prototype, based on a polymer wick structure filled with a specially designed hydrating solution is proposed for electroencephalography (EEG) applications. The new electrode does not require the use of a conventional electrolyte paste to achieve a wet, low-impedance scalp contact. When compared to standard commercial Ag/AgCl sensors, the proposed wick electrodes exhibit similar electrochemical noise and potential drift values. Lower impedances are observed when tested in human volunteers due to more effective electrode/skin contact. Furthermore, the electrodes exhibit an excellent autonomy, displaying an average interfacial impedance of 37±11 kΩ cm2 for 7 h of skin contact. After performing bipolar EEG trials in human volunteers, no substantial differences are evident in terms of shape, amplitude and spectral characteristics between signals of wick and commercial wet electrodes. Thus, the wick electrodes can be considered suitable to be used for rapid EEG applications (electrodes can be prepared without the presence of the patient) without the traditional electrolyte paste. The main advantages of these novel electrodes over the Ag/AgCl system are their low and stable impedance (obtained without conventional paste), long autonomy, comfort, lack of dirtying or damaging of the hair and because only a minimal cleaning procedure is required after the exam.