Thomas Luyckx

Prof. Dr. Thomas Luyckx

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2014 in Arthroscopy
Verified
Journal Article
Closed access
SCSteven Claes
Steven Claes
TLThomas Luyckx
Thomas Luyckx
EVEvie Vereecke
Evie Vereecke
JBJohan Bellemans
Johan Bellemans

31 July 2020 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Open access
PDF file
PGPhilip Winnock de Grave
Philip Winnock de Grave
TLThomas Luyckx
Thomas Luyckx
KCKurt Claeys
Kurt Claeys
TTThomas Tampere
Thomas Tampere
JKJonas Kellens
Jonas Kellens
PGPaul Gunst
Paul Gunst
Purpose: Various alignment philosophies for total knee arthroplasty (TKA) have been described, all striving to achieve excellent long‐term implant survival and good functional outcomes. In recent years, in search of higher functionality and patient satisfaction, a shift towards more tailored and patient‐specific alignment is seen. The purpose of this study was to describe a restricted ‘inverse kinematic alignment’ (iKA) technique, and to compare clinical outcomes of patients that underwent robotic‐assisted TKA performed by restricted iKA vs. adjusted mechanical alignment (aMA).Methods: The authors reviewed the records of a consecutive series of patients that received robotic‐assisted TKA with restricted iKA (n = 40) and with aMA (n = 40). Oxford Knee Score (OKS) and satisfaction on a visual analogue scale (VAS) were collected at a follow‐up of 12 months. Clinical outcomes were assessed according to patient acceptable symptom state (PASS) thresholds, and uni‐ and multivariable linear regression analyses were performed to determine associations of OKS and satisfaction with six variables (age, sex, body mass index (BMI), preoperative hip–knee–ankle (HKA) angle, preoperative OKS, alignment technique).Results: The restricted iKA and aMA techniques yielded comparable outcome scores (p = 0.069), with OKS, respectively, 44.6 ± 3.5 and 42.2 ± 6.3. VAS Satisfaction was better (p = 0.012) with restricted iKA (9.2 ± 0.8) compared to aMA (8.5 ± 1.3). The number of patients that achieved OKS and satisfaction PASS thresholds was significantly higher (p = 0.049 and p = 0.003, respectively) using restricted iKA (98% and 80%) compared to aMA (85% and 48%). Knees with preoperative varus deformity, achieved significantly (p = 0.025) better OKS using restricted iKA (45.4 ± 2.0) compared to aMA (41.4 ± 6.8). Multivariable analyses confirmed better OKS (β = 3.1; p = 0.007) and satisfaction (β = 0.73; p = 0.005) with restricted iKA.Conclusions: The results of this study suggest that restricted iKA and aMA grant comparable clinical outcomes at 12‐month follow‐up, though a greater proportion of knees operated by restricted iKA achieved the PASS thresholds for OKS and satisfaction. Notably. in knees with preoperative varus deformity, restricted iKA yielded significantly better OKS and satisfaction than aMA.Level of evidence: Level III, comparative study.

1 March 2009 in The Journal of Bone and Joint Surgery. British volume
Verified
Journal Article
Closed access
PDF file
TLThomas Luyckx
Thomas Luyckx
KDK. Didden
K. Didden
HVH. Vandenneucker
H. Vandenneucker
LLLuc Labey
Luc Labey
Bernardo InnocentiBernardo Innocenti
Bernardo Innocenti
JBJ. Bellemans
J. Bellemans
The purpose of this study was to test the hypothesis that patella alta leads to a less favourable situation in terms of patellofemoral contact force, contact area and contact pressure than the normal patellar position, and thereby gives rise to anterior knee pain.A dynamic knee simulator system based on the Oxford rig and allowing six degrees of freedom was adapted in order to simulate and record the dynamic loads during a knee squat from 30° to 120° flexion under physiological conditions. Five different configurations were studied, with variable predetermined patellar heights.The patellofemoral contact force increased with increasing knee flexion until contact occurred between the quadriceps tendon and the femoral trochlea, inducing load sharing. Patella alta caused a delay of this contact until deeper flexion. As a consequence, the maximal patellofemoral contact force and contact pressure increased significantly with increasing patellar height (p < 0.01). Patella alta was associated with the highest maximal patellofemoral contact force and contact pressure. When averaged across all flexion angles, a normal patellar position was associated with the lowest contact pressures.Our results indicate that there is a biomechanical reason for anterior knee pain in patients with patella alta.

13 February 2018 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
PDF file
TLThomas Luyckx
Thomas Luyckx
HVHilde Vandenneucker
Hilde Vandenneucker
LSLennart Scheys
Lennart Scheys
EVEvie Vereecke
Evie Vereecke
AIArnout Victor Ing
Arnout Victor Ing
JVJan Victor
Jan Victor
Background: In a typical osteoarthritic knee with varus deformity, distal femoral resection based off the worn medial femoral condyle may result in an elevated joint line. In a setting of fixed flexion contracture, the surgeon may choose to resect additional distal femur to obtain extension, thus purposefully raising the joint line. However, the biomechanical effect of raising the joint line is not well recognized. Questions/purposes: (1) What is the effect of the level of the medial joint line (restored versus raised) on coronal plane stability of a TKA? (2) Does coronal alignment technique (mechanical axis versus kinematic technique) affect coronal plane stability of the knee? (3) Can the effect of medial joint-line elevation on coronal plane laxity be predicted by an analytical model? Methods: A TKA prosthesis was implanted in 10 fresh frozen nonarthritic cadaveric knees with restoration of the medial joint line at its original level (TKA0). Coronal plane stability was measured at 0°, 30°, 60°, 90°, and 120° flexion using a navigation system while applying an instrumented 9.8-Nm varus and valgus force moment. The joint line then was raised in two steps by recutting the distal and posterior femur by an extra 2 mm (TKA2) and 4 mm (TKA4), downsizing the femoral component and, respectively, adding a 2- and a 4-mm thicker insert. This was done with meticulous protection of the ligaments to avoid damage. Second, a simplified two-dimensional analytical model of the superficial medial collateral ligament (MCL) length based on a single flexion-extension axis was developed. The effect of raising the joint line on the length of the superficial MCL was simulated. Results: Despite that at 0° (2.2° ± 1.5° versus 2.3° ± 1.1° versus 2.5° ± 1.1°; p = 0.85) and 90° (7.5° ± 1.9° versus 9.0° ± 3.1° versus 9.0° ± 3.5°; p = 0.66), there was no difference in coronal plane laxity between the TKA0, TKA2, and TKA4 positions, increased laxity at 30° (4.8° ± 1.9° versus 7.9° ± 2.3° versus 10.2° ± 2.0°; p < 0.001) and 60° (5.7° ± 2.7° versus 8.8° ± 2.9° versus 11.3° ± 2.9°; p < 0.001) was observed when the medial joint line was raised 2 and 4 mm. At 30°, this corresponds to an average increase of 64% (3.1°; p < 0.01) in mid-flexion laxity with a 2-mm raised joint line and a 111% (5.4°; p < 0.01) increase with a 4-mm raised joint line compared with the 9-mm baseline resection. No differences in coronal alignment were found between the knees implanted with kinematic alignment versus mechanical alignment at any flexion angle. The analytical model was consistent with the cadaveric findings and showed lengthening of the superficial MCL in mid-flexion. Conclusions: Despite a well-balanced knee in full extension and at 90° flexion, increased mid-flexion laxity in the coronal plane was evident in the specimens where the joint line was raised. Clinical Relevance: When recutting the distal and posterior femur and downsizing the femoral component, surgeons should be aware that this action might increase the laxity in mid-flexion, even if the knee is stable at 0° and 90°.

1 September 2018 in The Journal of Arthroplasty
Verified
Journal Article
Open access
PGPhilip Winnock de Grave
Philip Winnock de Grave
JBJustine Barbier
Justine Barbier
TLThomas Luyckx
Thomas Luyckx
ARAlexander Ryckaert
Alexander Ryckaert
PGPaul Gunst
Paul Gunst
LDLuc Van Den Daelen
Luc Van Den Daelen
Unicompartmental knee arthroplasty (UKA) is an alternative to total knee arthroplasty in isolated medial osteoarthritis (OA). However, despite satisfactory reports on the clinical performance, UKA revision rates are still concerning. This retrospective study reports on the long-term survivorship, functional outcomes, and reasons for revision in fixed-bearing UKA implant. Between 2005 and 2013, 460 consecutive patients were treated with medial UKA in one center using a fixed-bearing UKA system. All patients were evaluated clinically and radiographically before surgery, and postoperatively at 6 weeks and 1 year. Between February and April 2016, all patients were reevaluated using the Oxford Knee Score. Mean follow-up was 5.5 (range, 2-11) years. The mean Oxford Knee Score was 43.3 (7-48), with 94.6% patients showing excellent or good outcomes. Eleven revisions (2.4%) occurred. The survivorship was 97.2% (95% confidence interval, 96.2%-99.2%) and 94.2% (95% confidence interval, 86.8%-97.5%) at 5 and 10 years, respectively, with revision of any implant component for any reason as the end point. The causes for revision were infection (4 cases, 0.9%); lateral pain due to overload (2 cases, 0.4%); progression of OA in the lateral compartment (2 cases, 0.4%); patellar pain with patellar chondropathy (2 cases, 0.4%); and severe synovitis (1 cases, 0.2%). There were no reoperations or revisions for component loosening, instability, component wear, or periprosthetic fracture. A fixed-bearing UKA system is a good treatment option for medial end-stage OA. Satisfactory functional results were achieved with low incidence of complications and revisions.

1 January 2014 in Journal of Experimental Orthopaedics
Verified
Journal Article
Open access
PDF file
TLThomas Luyckx
Thomas Luyckx
MVMatthias Verstraete
Matthias Verstraete
KRKarel De Roo
Karel De Roo
Wim De WaeleWim De Waele
Wim De Waele
JBJohan Bellemans
Johan Bellemans
JVJan Victor
Jan Victor
Background: Determining the mechanical behaviour of tendon and ligamentous tissue remains challenging, as it is anisotropic, non‐linear and inhomogeneous in nature.Methods: In this study, three‐dimensional (3D) digital image correlation (DIC) was adopted to examine the strain distribution in the human Achilles tendon. Therefore, 6 fresh frozen human Achilles tendon specimens were mounted in a custom made rig for uni‐axial loading. 3D DIC measurements of each loading position were obtained and compared to 2 linear variable differential transformers (LVDT’s).Results: 3D DIC was able to calculate tendon strain in every region of all obtained images. The scatter was found to be low in all specimens and comparable to that obtained in steel applications. The accuracy of the 3D DIC measurement was higher in the centre of the specimen where scatter values around 0.03% strain were obtained. The overall scatter remained below 0.3% in all specimens. The spatial resolution of 3D DIC on human tendon tissue was found to be 0.1 mm2. The correlation coefficient between the 3D DIC measurements and the LVDT measurements showed an excellent linear agreement in all specimens (R2 = 0.99). Apart from the longitudinal strain component, an important transverse strain component was revealed in all specimens. The strain distribution of both components was of a strongly inhomogeneous nature, both within the same specimen and amongst different specimens.Conclusion: DIC proved to be a very accurate and reproducible tool for 3D strain analysis in human tendon tissue.