A forward imaging endoscope for optical coherence tomography angiography (OCTA) featuring a piezoelectric fiber scanner is presented. Imaging is performed with an optical coherence tomography (OCT) system incorporating an akinetic light source with a center wavelength of 1300 nm, bandwidth of 90 nm and A‐line rate of 173 kHz. The endoscope operates in contact mode to avoid motion artifacts, in particular, beneficial for OCTA measurements, and achieves a transversal resolution of 12 μm in air at a rigid probe size of 4 mm in diameter and 11.3 mm in length. A spiral scan pattern is generated at a scanning frequency of 360 Hz to sample a maximum field of view of 1.3 mm. OCT images of a human finger as well as visualization of microvasculature of the human palm are presented both in two and three dimensions. The combination of morphological tissue contrast with qualitative dynamic blood flow information within this endoscopic imaging approach potentially enables improved early diagnostic capabilities of internal organs for diseases such as bladder cancer.
Optical coherence tomography (OCT) is a noninvasive imaging technique that performs cross-sectional imaging of transparent, translucent, or turbid media at a micrometer scale resolution.1 Being already well established in ophthalmology,2 OCT also holds the potential to become an important tool for in vivo imaging of internal organs by combination with endoscopy. To investigate less accessible tissues in the human body and tissues shielded by opaque media, an integration of the coherent imaging technique into endoscopic instruments proved successful.3,4 Cancer lesions and other types of pathologic tissue changes typically arise from close underneath the tissue surface, which is well accessible for OCT. Therefore, endoscopic OCT enables disease diagnosis in internal organs at an early stage and complements the information obtained by white-light endoscopy.5 In a best-case scenario, thus, endoscopic OCT avoids the need to remove tissue samples by providing morphological tissue information at up to 2 mm in depth and, therefore, also being considered as “optical biopsy.”5 Furthermore, endoscopic OCT shows a tremendous impact in imaging of regions where common biopsy cannot be performed without introducing major risks, e.g., in the vascular system or in the brain.6
The current gold standard for endoscopic visualization of vessel networks is narrow-band imaging (NBI), which requires the integration of a filter in a standard commercially available white-light endoscope. The method was developed in 1999 and first described in 2001 for gastrointestinal applications.1 The usage of a filter narrows down the bandwidth of the transmitted white light to a certain wavelength region.2 Most commonly, wavelengths around 415 nm (blue) or 540 nm (green) are chosen since these wavelengths correspond to the hemoglobin absorption band.3 Consequently, light is absorbed by the blood running through the vessels and the contrast between the mucosal layer and vasculature is enhanced. Choosing a longer wavelength will lead to an increased penetration depth inside the tissue and therefore enables visualization of slightly deeper located vessels. A change from 415 to 540 nm, for example, has an increased penetration depth of (, compared to ).2 This technique has been successfully applied in various endoscopic applications and shows improvement compared to conventional endoscopy in terms of visualization of cancer lesions and differentiation between neoplasia and non-neoplasia.4 NBI hence has been reported to improve diagnostic capabilities for application in several fields, such as diagnosis of Barrett’s esophagus,5 detection of colorectal lesions,4 and improved visualization of gastric cancer.5
We demonstrate in vivo endoscopic optical coherence tomography (OCT) imaging in the forward direction using a flexible fiber bundle. In comparison to current conventional forward looking probe schemes, our approach simplifies the endoscope design by avoiding the integration of any beam steering components in the distal probe end due to 2D scanning of a focused light beam over the proximal fiber bundle surface. We describe the challenges that arise when OCT imaging with a fiber bundle is performed, such as multimoding or cross-coupling. The performance of different fiber bundles with varying parameters such as numerical aperture, core size and core structure was consequently compared and artifacts that degrade the image quality were described in detail. Based on our findings, we propose an optimal fiber bundle design for endoscopic OCT imaging.